Sick MOC3ZA-KAZ34D3

Sick MOC3ZA-KAZ34D3
We ship to United States of America!
  • Standstill monitoring by means of residual voltage measurement
  • 3 normally open and 1 normally closed positively guided safety contacts
  • 2 application diagnostic outputs for semiconductors
Item Number: MOC3ZA-KAZ34D3
721.11
-
+
Total price: 721.11
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Specification:

Part Number6047866
For UL 508 applications only:600 V AC
Mounting:35 mm mounting rail according to EN 60715
Enclosure rating terminals:IP 20
Weight:400 g
Stop category:1 (EN 60204-1)
Response time:100 ms
Measurement inputs:L1/L2/L3
Contact service life at 230 V / 5 A (AC) cos φ = 0.5:≥ 2 1E 05 switching operations
Mechanical life:≥ 50 1E 06 switching operations
Signal contacts 53/54 (normally open contact):3 A/250 V AC G. P.
Performance level:PL e (EN ISO 13849-1)
Standstill time ts:0.2 s ... 6 s, adjustable
Hysteresis (for detection of running motor):100 %
TM (mission time):20 a (EN ISO 13849)
Category:Category 4 (EN ISO 13849-1)
PFHd:41 1E-09 (EN ISO 13849)
Maximum switching frequency:1,200 /h
Contact type:Relay, positively guided
Protection class housing:IP 40
Dimensions (W x H x D):45 mm x 112 mm x 121 mm
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Switching capacity in accordance with AC 15:N/C: 2 A/230 V AC (EN 60947-5-1), N/O: 3 A/230 V AC (EN 60947-5-1)
Semiconductor application diagnostics outputs (ON, ERR):Electrically isolated supply via A3/A4, Imax = 100 mA (short-circuit protected), ON for Release, ERR for Error
Power consumption:4 W
Standstill:+
Safe state in the event of a fault:The N/O is open; in other words, the safety-related enabling current paths are interrupted.
Vibration resistance:(EN 60068-2-6)
Contact configuration (safety contacts):3 contacts NO, 1 contact NC
Voltage threshold Uan:20 mV ... 400 mV, adjustable
Supply voltage semiconductor diagnostic outputs (A3/A4):24 V DC (11 V DC ... 30 V DC)
Climate conditions according to:25/060/04 (EN 60068-1)
Nominal switching voltage:250 V AC
Switching capacity in accordance with DC 13:2 A/24 V DC (EN 60947-5-1)
Safety outputs:Normally open contact (13/14, 23/24, 33/34)
Measured/motor voltage:690 V AC
Positively guided N/C contacts:Normally closed contact (41/42)

Buy Sick MOC3ZA-KAZ34D3 with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com is your reliable source for industrial electrical parts. Our extensive product range includes various automation equipment, all available for fast delivery. We guarantee quality and competitive prices. Make us your preferred partner for all your electrical supply needs.

Comments

No comments yet

Write a comment