Sick MZZ1-03V-N-AW0
Magnetic Cylinder Sensors
We ship to United States of America!
- Classification T?V 99 ATEX 1398 EX II 2 G Ex ia IIC T6 Ta
- Corresponds to Category 2G
- Switching output: EN 60 947-5-6 (NAMUR)
Item Number:
MZZ1-03V-N-AW0
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
The product has been Discontinued by the Manufacturer!
Contact sales manager for a replacement.
Specification:
Part Number | 7901323 |
Reverse polarity protection: | + |
Enclosure rating: | IP 67 |
Shock/vibration: | 30 g, 11 ms / 10 ... 55 Hz, 1 mm |
Connection type: | Cable, 2-wire, 2 m |
Sensing face: | Front |
Housing material: | Metal, Aluminum |
Hazardous area category: | 2G |
EMC: | According to EN 60947-5-6 |
Cylinder type: | Tie rod cylinder |
Electrical wiring: | DC 2-wire |
Short-circuit protection: | + |
Switching output: | NAMUR |
Cable material: | PVC |
Dimensions (W x H x D): | 30 mm |
Magnetic field sensitivity, min.: | 3 mT |
Supply voltage: | 5 V DC ... 25 V DC |
Time delay before availability: | ≤ 2 ms |
Ambient operating temperature: | -25 °C ... 70 °C |
Sensing face material: | Plastic |
Conductor cross-section: | 0.34 mm? |
Power-up pulse protection: | - |
Switching frequency typ.: | 5,000 Hz |
Repeatability: | ≤ 0.1 mm |
Buy Sick MZZ1-03V-N-AW0 with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. is your trusted partner for industrial automation products. Our extensive catalog features a wide range of top-quality components. We offer worldwide delivery and competitive pricing, ensuring you get what you need promptly. Experience exceptional service and support for your automation requirements.