Sick OD2-P120W60A2
Distance sensors
- Several measurement ranges from 26 mm ... 34 mm to 100 mm ... 500 mm
- CMOS receiving element for measurement independent of surface
- Easy, LED-based user and teach-in concept
Item Number:
OD2-P120W60A2
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Specification:
Part Number | 6036628 |
Power consumption : | ≤ 2.88 W |
Measuring range: | 60 mm ... 180 mm, 6 % ... 90 % remission |
Vibration resistance: | 10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) |
Shock resistance: | 50 G (x-, y-, z-axis 3 times each) |
Additional function: | Automatic sensitivity adjustment, Teach-in of switching output, Invertable switching output, Averaging 1 ... 64x, Multifunctional input: laser-off / external teach-in / trigger, Switching mode: distance to object (DtO), Switching mode: window (Wnd) |
Housing material: | PBT housing with PMMA lens |
Repeatability : | 90 µm |
Switching output : | 1 x PNP (100 mA) |
Protection class: | III |
Temperature drift: | ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor) |
Multifunctional input (MF) : | 1 x MF |
Supply voltage Vs : | DC 12 V ... 24 V |
Connection type: | Cable, 2 m |
Linearity : | ± 120 µm |
Light source: | Laser, red |
Enclosure rating: | IP 67 |
Ambient temperature: | Operation: -10 ... +40 °C, Storage: -20 ... +60 °C |
Weight: | 70 g |
Typ. light spot size (distance): | 1 mm x 1.5 mm (120 mm) |
Resolution : | 30 µm |
Typ. ambient light safety: | Artificial light: ≤ 3,000 lx Sunlight: ≤ 10,000 lx |
Response time : | 1 ms / 10 ms / 35 ms |
Warm-up time: | ≤ 5 min |
Data interface: | RS-422 |
Laser class: | 2 (EN 60825-1) |
Indication: | Distance bar graph, up to 8 status LEDs |
Relative humidity (not condensing): | 35 % ... 95 % |
Measuring frequency: | 2 kHz |
People also buy
Comments
No comments yet