Sick OD5000-C30W05
Displacement sensor

Sick OD5000-C30W05
We ship to United States of America!
OD5000-C30W05 DISPLAC.SENS, OPTICAL art. 6063622
Item Number: OD5000-C30W05
4937.81
-
+
Total price: 4937.81
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick OD5000-C30W05

Datasheet:

  • Article: 6063622
  • Supply voltage UV: DC. current 12 V ... 24 V, ± 10%, including residual ripple
  • Power consumption: 180 mA, at 24 V
  • Warm-up time: < 10 min
  • Housing material: Metal (Die-cast aluminum)
  • Front window material: Plastic (PMMA)
  • Connection type: Cable with connector, M12, 8-pin, A-coded, 50 cm
  • Indication: Status LEDs
  • Weight: 280 g
  • Dimensions (W x H x D): 25.9 mm x 71.5 mm x 53 ,2 mm
  • Protection type: IP67
  • Protection class: III (EN 50178)
  • Measurement range: 25 mm ... 35 mm
  • Measurement object: Natural objects
  • Reproduction accuracy: 0.05 µm
  • Linearity: Diffuse. ± 1.5 µm, near side, diffuse ± 1.5 µm, far side, Mirror ± 4 µm, near side, Mirror ± 4 µm, far side,
  • Rating: ? 12.5 µs
  • Measurement frequency: ? 80 kHz
  • Output time: ? 0.0125 ms
  • RADIATION SOURCE: Laser, red, Visible red
  • Laser class: 1 (IEC 60825-1:2014, EN 60825-1:2014)
  • Type . light spot size (distance): 30 µm x 1.000 µm
  • Special task: Measuring the thickness of transparent material
  • Measuring the thickness of transparent material: 0.18 mm ... 0.6 mm
  • Ethernet: ? , TCP/IP, UDP
  • PROFIBUS DP: ?
  • Digital input: In1, Can be used for shutdown laser, for external training or can be deactivated
  • Operating temperature range: –10 °C ... +50 °C, Operating temperature UV = 24 V
  • Storage temperature range: –20 °C ... +60 °C
  • Relative humidity (non-condensing): 35% ... 85%
  • Temperature drift: ± 0.01 % FS/K at –10 °C ... +40 °C (FS = Full Scale = sensor measuring range), ± 0.03 % FS/K at +40 °C ... + 50 °C (FS = Full Scale = sensor measuring range),
  • Typ. Immunity to extraneous light: Artificial lighting: ? 3,000 lx, Sunlight: ? 10,000 lx,
  • Vibration resistance: EN 60068-2-6, EN 60068-2-64
  • Shock resistance: EN 60068-2-27
  • Type of bus integration: Optional via external data evaluation unit AOD1 and gateway WI180C-PB
  • Quantity: 1 ... 3
  • Type: PNP/NPN, switchable
  • Quantity: 1
  • Type: Current output
  • Function: Optional via evaluation unit AOD1
  • Current: 4 mA ... 20 mA, ? 300 ?
  • Category: Displacement sensors
  • Series :OD5000

Comments

No comments yet