Sick PAC50-FGF
Pressure sensor

Sick PAC50-FGF
We ship to United States of America!

PAC50-FGF PRESSURE SWITCH art. 1086915

Item Number: PAC50-FGF
220.94
-
+
Total price: 220.94
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick PAC50-FGF

Datasheet:

  • Article: 1086915
  • Media: Dry compressed air
  • Pressure type: Relative pressure
  • Pressure unit: bar
  • Measuring range: –1 bar ... 10 bar
  • Overload protection: 15 bar
  • Operating temperature: 0 °C ... +60 °C
  • Analogue output signal and load capacity RA: Optional, 4-20 mA / 0-10 V. Automatic switching depending on the connected load or hard tuning. Invertible output signals: 20-4 mA / 10-0 V, Load resistance for current output < 600 ?, Load resistance for voltage output > 3 k?,
  • Zero point correction: Max. + 5% interval
  • Output signal: IO-Link/PNP + PNP/NPN/Push-Pull + 4 mA ... 20 mA / 0 V ... 10 V
  • Diagnostic output: Digital output 2 can be used as diagnostic output
  • Display: LCD with LED backlight (green/red), electronic, 180° rotatable, Pressure display: 4 digits, 16 segments, Unit of measurement switchable on the indicator: bar, MPa, kPa, psi and inHg, Update: 1000, 500, 200, 100 ms (programmable),
  • Initialization time: 300 ms
  • Technical connections: 2 x G ј
  • Housing material: Housing: polycarbonate, Pushbuttons: TPE, DIN rail mounting: POM, Seals: NBR
  • Connection type: Circular connector M12 x 1 , 5-pin
  • Supply voltage: 17–30 V DC
  • Current consumption: Max. 40 mA at L+ = 24 V DC
  • Electrical safety: Protection class: III, Overvoltage protection: 32 V DC, Short circuit resistance: QA, Q1, Q2 relative to M and L+, Polarity inversion protection: L+ relative M,
  • EC compliance: EU Electromagnetic Compatibility Directive: 2004/108/EC, EN 61326-2-3
  • Sensor weight: Approx. 40 g
  • Protection type: IP65 / IP67 (according to IEC 60529)
  • Protection class III: ?
  • RoHS certificate: ?
  • cRUus Certificate: ?
  • Non-linearity: ? ± 0.5% span (Best Fit Straight Line, BFSL) according to IEC 61298-2
  • Accuracy: ? ± 1.5% span
  • Setting accuracy of discrete outputs: ? ± 0.2% of span
  • Repeatability of measurement results: ? ± 0.2% of span
  • Range of nominal temperatures: +10 °C ... +60 °C
  • Ambient temperature: 0 °C ... +60 °C
  • Storage temperature: –20 °C ... +80 ° C
  • Relative humidity: ? 90%
  • Shock resistance: Max. 30 g, xyz, according to DIN EN 60068-2-27 (11 ms, mechanical shock)
  • Vibration resistance: Max. 5 g (10–150 Hz), xyz, according to DIN EN 60068-2-6
  • Pressure unit: bar
  • Category: Pressure sensors
  • Series: PAC50
  • Media: dry compressed air
  • Pressure type: relative pressure

Comments

No comments yet

Write a comment