Sick PAC50-FNF
Pressure sensor
We ship to United States of America!
PAC50-FNF PRESSURE SWITCH art. 1086917
Item Number:
PAC50-FNF
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Sick PAC50-FNF
Datasheet:
- Article: 1086917
- Media: Dry compressed air
- Pressure type: Relative pressure
- Pressure unit: bar
- Measuring range: –1 bar ... 10 bar
- Overload protection: 15 bar
- Operating temperature: 0 °C ... +60 °C
- Analogue output signal and load capacity RA: Optional, 4-20 mA / 0-10 V. Automatic switching depending on the connected load or hard tuning. Invertible output signals: 20-4 mA / 10-0 V, Load resistance for current output < 600 ?, Load resistance for voltage output > 3 k?,
- Zero point correction: Max. + 5% interval
- Output signal: IO-Link/PNP + PNP/NPN/Push-Pull + 4 mA ... 20 mA / 0 V ... 10 V
- Diagnostic output: Digital output 2 can be used as diagnostic output
- Display: LCD with LED backlight (green/red), electronic, 180° rotatable, Pressure display: 4 digits, 16 segments, Unit of measurement switchable on the indicator: bar, MPa, kPa, psi and inHg, Update: 1000, 500, 200, 100 ms (programmable),
- Initialization time: 300 ms
- Technical connections: ј" NPT female
- Housing material: Housing: polycarbonate, Pushbuttons: TPE, DIN rail mounting: POM, Seals: NBR
- Connection type: Circular connector M12 x 1 , 5-pin
- Supply voltage: 17–30 V DC
- Current consumption: Max 40 mA at L+ = 24 V DC
- Electrical safety: Protection class: III, Overvoltage protection: 32 V DC, Short circuit resistance: QA, Q1, Q2< /sub> relative to M and L+, Polarity inversion protection: L+ relative to M,
- EU compliance: EU Electromagnetic Compatibility Directive: 2004/108/EC, EN 61326-2-3
- Sensor weight: Approx. 40 g
- Protection type: IP65 / IP67 (according to IEC 60529)
- Protection class III: ?
- RoHS certificate: ?
- cRUus Certificate: ?
- Non-linearity: ? ± 0.5% span (Best Fit Straight Line, BFSL) according to IEC 61298-2
- Accuracy: ? ± 1.5% span
- Setting accuracy of discrete outputs: ? ± 0.2% of span
- Repeatability of measurement results: ? ± 0.2% of span
- Range of nominal temperatures: +10 °C ... +60 °C
- Ambient temperature: 0 °C ... +60 °C
- Storage temperature: –20 °C ... +80 ° C
- Relative humidity: ? 90%
- Shock resistance: Max. 30 g, xyz, according to DIN EN 60068-2-27 (11 ms, mechanical shock)
- Vibration resistance: Max. 5 g (10–150 Hz), xyz, according to DIN EN 60068-2-6
- Pressure unit: bar
- Category: Pressure sensors
- Series: PAC50
- Media: dry compressed air
- Pressure type: relative pressure
Buy Sick PAC50-FNF with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. is a trusted online electrical distributor. Our catalog includes a comprehensive range of automation products from leading brands. We offer worldwide delivery and competitive pricing. Streamline your supply chain with our reliable services and exceptional support.