Sick PBS2-RB250SG2SS0NMA0Z
Pressure sensor

Sick PBS2-RB250SG2SS0NMA0Z
We ship to United States of America!
PBS2-RB250SG2SS0NMA0Z art. 6073090
Item Number: PBS2-RB250SG2SS0NMA0Z
524.85
-
+
Total price: 524.85
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick PBS2-RB250SG2SS0NMA0Z

Datasheet:

  • Article: 6073090
  • Media: Liquid, gaseous
  • Pressure type: Relative pressure
  • Pressure unit: bar
  • Measuring range: 0 bar ... 250 bar, 0 psi ... 3626 psi
  • Operating temperature: –20 °C ... +85 °C
  • Correction zero points: Max. + 3 % interval
  • Output signal: IO-Link/PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V
  • Housing rotation: Display relative to housing with electrical connection: 330°, Housing to process connection: 320°,
  • Display: 14-segment LED, red, 4-digit, digit height 9 mm, electronically rotatable 180° , Update: 1000, 500, 200, 100 ms (programmable),
  • Technical connections: G ј internal
  • Wetted materials: Pressure connection: 316L stainless steel, Pressure sensor : 316L stainless steel (0 to 10 bar rel. 13-8 PH stainless steel),
  • Internal transmission fluid: Synthetic oil (only for measuring ranges < 0 bar to 10 bar and ? 0 bar abs. up to 25 bar abs.)
  • Channel opening: 3.5 mm, Standard
  • Case material: Lower part: 304 stainless steel, Upper part made of plastic: PC + ABS, Buttons: TPE-E, Screen glass: PC
  • Connection type: Round plug connector M12 x 1, 4-pin, IP67
  • Supply voltage: 15–35 V DC
  • Current consumption: 45 mA (for configurations without analog output), 70 mA (for configurations with analog output),
  • Total current consumption: Max. 600 mA (incl. switching current)
  • Electrical safety: Protection class: III, Overvoltage protection: 40 V DC, Short circuit resistance: QA, Q1 , Q2 relative to M, Polarity inversion protection: L+ relative to M,
  • Isolation voltage: 500 V DC
  • EU Compliance: EU Electromagnetic Compatibility Directive: 2014/30/EU (EN 61326-1:2013- EN 61326-2-3:2013), EU Pressure Equipment Directive: 2014/68/ EU, hazardous substances (RoHS): 2011/65/EU (EN 50581:2012)
  • Sensor weight: Approx. 220 g
  • Seal: Without seal
  • Protection type: IP67 / IP67
  • Protection class III: ?
  • Mean time to failure: > 100 years
  • Non-linearity: ? ± 0.25% span (Best Fit Straight Line, BFSL) according to IEC 61298-2
  • Accuracy: ? ± 0.5% span
  • Setting accuracy of discrete outputs: ? ± 0.5% of the interval
  • Transition time: ? 5 ms
  • Long-term drift/stability per year of operation: ? ± 0 .1% span according to IEC 61298-2, ? 0.2% span according to IEC 61298-2 for measuring range ? 0.6 bar or flush mounted diaphragm (0 psi…10 lbf/ sq. inch),
  • Temperature coefficients in the range of nominal temperatures: Average TC of the zero point: ? ± 0.16% of the interval / 10 K, average TC of the interval ? ± 0.16% of the interval / 10 K
  • Rated temperature range: 0 °C ... +80 °C
  • Service life: Minimum 100 million load cycles
  • Ambient temperature: –20 °C . .. +80 °C
  • Storage temperature: –20 °C ... +70 °C
  • Relative humidity: ? 75%
  • Resistance to shock: 50 g, 6 ms according to IEC 60068-2-27 (mechanical shock)
  • Vibration resistance: 20 g, 10 Hz ... 2000 Hz (IEC 60068-2-6, at resonance )
  • Pressure unit:bar
  • Category:Pressure sensors
  • Series:PBS plus
  • Media: liquids, gases
  • Pressure type: relative pressure

Comments

No comments yet

Write a comment