Sick PBT-RB600SGTSSNALA0Z Pressure sensor PBT

Sick PBT-RB600SGTSSNALA0Z
Item Number: PBT-RB600SGTSSNALA0Z
    110.35
    Quantity
    -
    +
    Total price: 110.35
    Contact our experts
    • Overview
    • Datasheet
    • Alternative numbers
    • PDF
    • Comments

    Specification:

    Part Number6052069
    Compound pressure:-1 bar ... 0 bar up to -1 bar ... +24 bar
    Internal transmission fluid:Silicone oil (only with pressure ranges < 0 bar ... 10 bar and ≤ 0 bar abs ... 25 bar abs)
    Relative humidity:45 % ... 75 %
    Isolation voltage:500 V DC
    Shock load:500 g according to IEC 60068-2-27 (mechanical shock)
    Medium:Liquid and gaseous media
    Accuracy:≤ ± 0,6 % of Span (with non-linearity 0.25 % and with signal output 0 ... 5 V), ≤ ± 1 % of span (with non-linearity 0.25 %), ≤ ± 1,0 % of Span (with non-linearity 0.5 %), (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2))
    Non-repeatability:≤ 0.1 % of span
    Housing material:Stainless steel 316L
    Wetted parts:Pressure connection: stainless steel 316L, Pressure sensor: stainless steel 316L (for measurement ranges from 0 bar ... 10 bar rel stainless steel 13-8 PH)
    Pressure type:Gauge pressure
    Adjustment accuracy of zero signal:≤ 0.5 % of span typ., ≤ 0.8 % of span max. (with non-linerarity 0.5 %)
    Vibration load:10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional
    Hysteresis:≤ 0.16 % of span
    Protection class III:+
    Power consumption:Max. 8 mA for voltage output signal, Signal current (max. 25 mA) for current output
    Long-term drift/one-year stability:≤ 0.1 % of span according to IEC 61298-2
    Pressure port:Standard
    Output signal:4 mA ... 20 mA
    Response time:< 4 ms
    Process connection:G ½ A according to DIN 3852-E
    Connection type:L-connector acc. to DIN 175301-803 A, IP 65
    Service life:Minimum 100 Mio. life cycles
    Gauge pressure:0 bar ... 1 bar up to bar ... 600 bar
    Measuring range:0 bar ... 600 bar
    Absolute pressure:0 bar ... 1 bar up to 0 bar ... 25 bar
    Weight sensor:Ca. 80 g
    Ambient temperature:0 °C ... +80 °C
    Enclosure rating:IP 65
    Non-linearity:≤ ± 0.5 % ((Best Fit Straight Line, BFSL) according to IEC 61298-2)
    CE-conformity:Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3
    Storage temperature:-20 °C ... +80 °C
    Reference conditions:Reference conditions: According to IEC 61298-1
    Seal:NBR
    Electrical safety:Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mA, Reverse polarity protection: L+ towards M
    Process temperature:0 °C ... +80 °C
    Rated temperature range:0 °C ... +80 °C
    Signal noise:≤ 0.3 % of span

    Comments

    No comments yet

    Write a comment