Sick PHT-RBX25ST10S0ALS0Z
Pressure sensor
We ship to United States of America!
PHT-RBX25ST10S0ALS0Z art. 6039347
Item Number:
PHT-RBX25ST10S0ALS0Z
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Sick PHT-RBX25ST10S0ALS0Z
Datasheet:
- Article: 6039347
- Media: Liquid, gaseous
- Pressure type: Relative pressure
- Pressure unit: bar
- Measuring range: 0 bar ... 0.25 bar
- Operating temperature: –20 °C ... +150 °C
- Output signal: 4 mA ... 20 mA, 2-wire
- EHEDG certified: ?
- Technical connections: Tri-Clamp 1 Ѕ"
- Wetted materials: Stainless steel 1.4435
- Internal transmission fluid: Synthetic oil, FDA compliant
- Housing material: Stainless steel 1.4571
- Connection type: Angled plug (DIN EN 175301-803 A), IP65
- Supply voltage: 10–30 V DC, 14–30 V DC with 0–10 V output signal, 11 V DC ... 30 V DC with 4 mA ... 20 mA output signal and field housing,
- Electrical safety: Overvoltage protection: 36 V DC, Short circuit resistance: QA relative to M, Polarity inversion protection: L+ relative to M, Protection class: III,
- Supply voltage failure: 500 V DC, Supply voltage NEC Class 02 (low voltage and low current max. 100 VA also in emergency condition)
- EC compliance: EU Electromagnetic Compatibility Directive: 2004/108/EC, EN 61326-2-3
- Sensor weight: Approx. 500 g
- Seal: Without seal
- Protection type: IP65
- Protection class III: ?
- Non-linearity: ? ± 0.2 %, span (Best Fit Straight Line, BFSL) according to IEC 61298-2
- Accuracy: ? ± 0.5% span
- Measurement repeatability: ? ± 0.1% span
- Tuning time (10–90%): ? 10 ms
- Long-term drift/stability per year of operation: ? 0.2% of interval
- Temperature coefficients in range of nominal temperatures: Average TC of the zero point: ? 0.2% of the span/10 K for measuring ranges from 0–0.6 bar to 0–25 bar, Average TC of the zero point: ? 0.25% of the span/10 K for the range measurement 0–0.4 bar, Average TC of zero point: ? 0.4% of span/10 K for measuring range 0–0.25 bar, Average TC of span ? 0.2% of span/10 K
- Range of nominal temperatures: 0 °C ... +80 °C
- Ambient temperature: –20 °C ... +80 °C
- Storage temperature: –40 ° C ... +100 °C
- Shock resistance: 500 g according to IEC 60068-2-27 (mechanical shock)
- Vibration resistance: 15 g according to IEC 60068-2 -6 (vibration at resonance)
- Pressure unit: bar
- Category: Sensors pressure
- Series:PHT
- Media: gases, liquids
- Pressure type< /strong>:relative pressure
Buy Sick PHT-RBX25ST10S0ALS0Z with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. is fast developing company in automation products. We have a great range of products and can cover most of your electrical and automation equipment needs. We sell automation equipment all over the world. Buy the original product at a reasonable price on our website. We always try to find the best delivery times and prices for all necessary products. We always work on results.