- Reliability class: SIL3 (IEC 61508), SILCL3 (IEC 62061),
- Category: Category 4 (ISO 13849-1)
- Performance level: PL e (ISO 13849-1)
- PFHd (average probability of dangerous failure per hour): 1.0 x 10-9
- TM (specified operating time): 20 years ( ISO 13849-1)
- Safe state in the event of an error: The normally open contacts are open, i.e. the safety-oriented enabling circuits are interrupted.
- Stop category: 0 (IEC 60204-1)
- Sensor control: Sequential control
- Restart interlock: ?
- Reset: Automatic, Manual,
- External device control (EDM): ?
- Connection Type: Front Plug with Spring Clamps
- Inputs: 2 Safety Inputs, 1 Reset Button or External Device Monitor (EDM) Input,
- li>Outputs: 3 unlocking circuits (safe), 2 diagnostic outputs (not safe), 1 test pulse output (not safe),
- Indication elements: LEDs
- Configuration type: Via connecting wiring
- Supply voltage: PELV or SELV
- Supply voltage UV: 24 V DC (16.8 V ... 30 V) li>
- Residual ripple: ? 2.4 V
- Power consumption: ? 2.5 W (DC)
- Quantity: 2
- Input current : 4 mA ... 6 mA
- Control pulse width: ? 1 ms
- Control pulse frequency: ? 10 Hz
- Quantity: 1
- Input current: 4 mA ... 6 mA
- Rating: 12 ms
- Quantity: 3
- Output type: Normally open contacts, with forced control
- Contact material: Silver alloy, fine gold plating
- Switching voltage: 10 V AC ... 230 V AC, 10 V DC ... 230 V DC,
- Switching current: 10 mA ... 6 A
- Total current: 12 A
- Service life of mechanical components: 1 x 107 operating cycles
- Overvoltage category: III (EN 60664-1)
- Maximum permissible impulse voltage Uimp: 6 kV (EN 60664-1)
- Quantity: 2
- Output type: Push-Pull semiconductor output, short-circuit protected
- Input current (NPN): ? 15 mA
- Output current (PNP): ? 120 mA
- Quantity: 1
- Output type: PNP semiconductor, short-circuit protected
- Output voltage: ? UV – 3 V
- Test pulse width: 2 ms
- Test pulse interval: 40 ms
- Dimensions (W x H x D) : 18 mm x 124.6 mm x 85.5 mm
- Weight: 150 g
- Protection type: IP20 (IEC 60529)
- Operating temperature range: –25 °C ... +55 °C
- Storage temperature: –25 °C ... +70 °C
- Air humidity: 10% ... 95%, non-condensing
- Interference emission: According to IEC 61000-6-4
- Immunity to interference: According to IEC 61326-3-1, According to IEC 61000-6-2, According to IEC 60947-5 -1,
- HIGH: 24 V DC (11 V ... 30 V)
- LOW: 0 V DC (–3 V ... 5 V)
- HIGH: 24 V DC (11 V ... 30 V)
- LOW: 0 V DC (–3 V ... 5 V)
- HIGH: ? U V – 3 V
- LOW: ? 3 V