Sick RLY3-OSSD300
Protection relay

Sick RLY3-OSSD300
We ship to United States of America!
RLY3-OSSD300 RELY art. 1099969
Item Number: RLY3-OSSD300
335.40
-
+
Total price: 335.40
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick RLY3-OSSD300

Datasheet:

  • Article: 1099969
  • Application: Data processing device
  • Compatible sensor types: Safety sensors with OSSD outputs
  • Reliability class: SIL3 (IEC 61508), SILCL3 (IEC 62061),
  • Category: Category 4 (ISO 13849-1)
  • Performance level: PL e (ISO 13849-1)
  • PFHd (average probability of dangerous failure per hour): 1.0 x 10-9
  • TM (specified operating time): 20 years ( ISO 13849-1)
  • Safe state in the event of an error: The normally open contacts are open, i.e. the safety-oriented enabling circuits are interrupted.
  • Stop category: 0 (IEC 60204-1)
  • Sensor control: Sequential control
  • Restart interlock: ?
  • Reset: Automatic, Manual,
  • External device control (EDM): ?
  • Connection Type: Front Plug with Spring Clamps
  • Inputs: 2 Safety Inputs, 1 Reset Button or External Device Monitor (EDM) Input,
  • li>Outputs: 3 unlocking circuits (safe), 2 diagnostic outputs (not safe), 1 test pulse output (not safe),
  • Indication elements: LEDs
  • Configuration type: Via connecting wiring
  • Supply voltage: PELV or SELV
  • Supply voltage UV: 24 V DC (16.8 V ... 30 V)
  • Residual ripple: ? 2.4 V
  • Power consumption: ? 2.5 W (DC)
  • Quantity: 2
  • Input current : 4 mA ... 6 mA
  • Control pulse width: ? 1 ms
  • Control pulse frequency: ? 10 Hz
  • Quantity: 1
  • Input current: 4 mA ... 6 mA
  • Rating: 12 ms
  • Quantity: 3
  • Output type: Normally open contacts, with forced control
  • Contact material: Silver alloy, fine gold plating
  • Switching voltage: 10 V AC ... 230 V AC, 10 V DC ... 230 V DC,
  • Switching current: 10 mA ... 6 A
  • Total current: 12 A
  • Service life of mechanical components: 1 x 107 operating cycles
  • Overvoltage category: III (EN 60664-1)
  • Maximum permissible impulse voltage Uimp: 6 kV (EN 60664-1)
  • Quantity: 2
  • Output type: Push-Pull semiconductor output, short-circuit protected
  • Input current (NPN): ? 15 mA
  • Output current (PNP): ? 120 mA
  • Quantity: 1
  • Output type: PNP semiconductor, short-circuit protected
  • Output voltage: ? UV – 3 V
  • Test pulse width: 2 ms
  • Test pulse interval: 40 ms
  • Dimensions (W x H x D) : 18 mm x 124.6 mm x 85.5 mm
  • Weight: 150 g
  • Protection type: IP20 (IEC 60529)
  • Operating temperature range: –25 °C ... +55 °C
  • Storage temperature: –25 °C ... +70 °C
  • Air humidity: 10% ... 95%, non-condensing
  • Interference emission: According to IEC 61000-6-4
  • Immunity to interference: According to IEC 61326-3-1, According to IEC 61000-6-2, According to IEC 60947-5 -1,
  • HIGH: 24 V DC (11 V ... 30 V)
  • LOW: 0 V DC (–3 V ... 5 V)
  • HIGH: 24 V DC (11 V ... 30 V)
  • LOW: 0 V DC (–3 V ... 5 V)
  • HIGH: ? U V – 3 V
  • LOW: ? 3 V
  • Category: Protective relays
  • Series:ReLy

Buy Sick RLY3-OSSD300 with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com offers an extensive range of industrial electrical products. We specialize in sourcing and delivering hard-to-find parts promptly. Our commitment to quality and competitive pricing makes us a preferred supplier. Partner with us for reliable and efficient electrical supply solutions.

Comments

No comments yet

Write a comment