Sick S30A-4011EA
Laser Scanner, laser safety scanner , Sick Safety Sensors

Sick S30A-4011EA
  • Can only be used in EFI system network, e.g., with a Flexi Soft safety controller or another safety laser scanner
  • 4 m protective field range
  • Up to 32 switchable field sets
Item Number: S30A-4011EA
4656.80
-
+
Total price: 4656.80
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1028938
PFHd:8.0 1E-08 (EN ISO 13849)
Maximum warning field range:49 m
Access protection (vertical):+
Number of application diagnostic outputs:3
Category:Category 3 (EN ISO 13849)
Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable
Measured data output:+
Number of multiple samplings:Configurable 2 ... 16
Hazardous area protection (horizontal):+
Expanded measured data output (CMS):-
Response time:60 ms
Number of monitoring cases:32
Ambient operating temperature:-10 °C ... +50 °C
Number of EDM inputs:1
Electrical connection:System plug with or without connecting cable
Type:Type 3 (IEC 61496)
Protection class:II (EN 50178)
Distance measuring range:49 m
Incremental encoder inputs:+
Number of reset-/restart inputs:1
Number of static control inputs with EFI:5
Static protective field switching:+
Number of safe outputs:2, Safety outputs (OSSD)
Enclosure rating:IP 65 (EN 60529)
Safe SICK device communication via EFI/SDL:+
Dimensions (W x H x D):155 mm x 185 mm x 160 mm
Performance level:PL d (EN ISO 13849)
Scan angle:190 °
Number of simultaneously monitored protective fields:≤ 4
Maximum output current:500 mA
External device monitoring (EDM):+
Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Type of field set:Dual field sets, Triple field sets
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Protective field range:4 m
Data interface:RS-422
Integrated configuration memory:+
Weight:3.3 kg
Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
Configuration and diagnostics interface:RS-232
Number of field sets:32
Hazardous area protection (vertical):+
TM (mission time):20 a (EN ISO 13849)

Comments

No comments yet

Write a comment