Sick S30A-4111CL
Safety laser scanner

Sick S30A-4111CL
  • Direct integration in PROFINET IO safe bus system
  • 4 m protective field range
  • 4 switchable field sets
Item Number: S30A-4111CL
6209.77
-
+
Total price: 6209.77
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1052591
Type of field set:Dual field sets
Number of simultaneously monitored protective fields:2
Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
TM (mission time):20 a (EN ISO 13849)
External device monitoring (EDM):-
Response time:60 ms
Type:Type 3 (IEC 61496)
Port properties:Auto-negotiation
Auto-crossover (MDIX)
Auto-polarity
100Base-FX
Enclosure rating:IP 65 (EN 60529)
Incremental encoder inputs:-
Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
Device properties:GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc.
Conformance:Conformance Class B
Static protective field switching:+
Dimensions (W x H x D):155 mm x 185 mm x 160 mm
Expanded measured data output (CMS):-
Diagnostics:Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable
Report system errors
Maintenance alerts for POF interfaces for signal quality
Cable diagnostics
Neighborhood alerts
Support for port statistics
I&M support from I&M0 to I&M4
Scan angle:190 °
Number of multiple samplings:Configurable 2 ... 16
Weight:3.3 kg
Protection class:III (VDE 0106, EN 60950)
Configuration and diagnostics interface:RS-232
Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Hazardous area protection (vertical):+
Number of monitoring cases:4
Hazardous area protection (horizontal):+
Ambient operating temperature:-10 °C ... +50 °C
Maximum warning field range:49 m
Interfaces for configuration and diagnostics using CDS:TCP port 9000 and UDP port 30718
RS-232
Integrated configuration memory:+
Topology support:SNMP, MIB-2, LLDP nach IEEE 802.1AB
MRP client support
Switch properties:Filtering Data Base according to IEEE 802.1D
6 prioritization levels for IEEE 802.1Q - Network prioritization
64 KB SRAM memory for caching telegrams, managed in 768-byte segments
Resource prioritization for network control and RTC2/3 frames
Telegram extension based on "Cut-through"
Port status (Disabled, Blocking, Forwarding)
Support for non-real-time and real-time data transfer
Measured data output:+
Category:Category 3 (EN ISO 13849)
Functions that are not supported:Multicast communication
Supervisor AR
MAC-pause mechanism in full duplex
Back-pressure in half duplex
Static learning
Broadcast Storm Control
Distance measuring range:49 m
Electrical connection:Optical fiber conductor (2 female connectors for SCRJ push-pull plug), system plug with or without connecting cable
Performance level:PL d (EN ISO 13849)
PFHd:8.0 1E-08 (EN ISO 13849)
Safe SICK device communication via EFI/SDL:-
Number of field sets:4
Access protection (vertical):+
Protective field range:4 m

Comments

No comments yet

Write a comment