Sick S30A-4111CP
Laser Scanner, laser safety scanner , Sick Safety Sensors
- Direct integration in PROFINET IO safe bus system
- 4 m protective field range
- 4 switchable field sets (four protective fields, four warning fields)
Item Number:
S30A-4111CP
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Specification:
Part Number | 1045650 |
Hazardous area protection (horizontal): | + |
Number of multiple samplings: | Configurable 2 ... 16 |
Performance level: | PL d (EN ISO 13849) |
Incremental encoder inputs: | - |
Conformance: | Conformance Class B |
Safe SICK device communication via EFI/SDL: | - |
Maximum warning field range: | 49 m |
Access protection (vertical): | + |
Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
Diagnostics: | Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable Report system errors Cable diagnostics Neighborhood alerts Support for port statistics I&M support from I&M0 to I&M4 |
Weight: | 3.3 kg |
Type: | Type 3 (IEC 61496) |
Number of monitoring cases: | 4 |
Measured data output: | + |
Device properties: | GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc. |
Functions that are not supported: | Multicast communication Supervisor AR MAC-pause mechanism in full duplex Back-pressure in half duplex Static learning Broadcast Storm Control |
Topology support: | SNMP, MIB-2, LLDP nach IEEE 802.1AB MRP client support |
Hazardous area protection (vertical): | + |
Interfaces for configuration and diagnostics using CDS: | TCP port 9000 and UDP port 30718 RS-232 |
Type of field set: | Dual field sets |
PFHd: | 8.0 1E-08 (EN ISO 13849) |
Protection class: | III (VDE 0106, EN 60950) |
Dimensions (W x H x D): | 155 mm x 185 mm x 160 mm |
Distance measuring range: | 49 m |
Configuration and diagnostics interface: | RS-232 |
Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable |
External device monitoring (EDM): | - |
Protective field range: | 4 m |
Response time: | 60 ms |
Static protective field switching: | + |
Supply voltage: | 16.8 V DC, 24 V DC, 28.8 V DC |
Number of simultaneously monitored protective fields: | 2 |
Integrated configuration memory: | + |
Switch properties: | Filtering Data Base according to IEEE 802.1D 6 prioritization levels for IEEE 802.1Q - Network prioritization 64 KB SRAM memory for caching telegrams, managed in 768-byte segments Resource prioritization for network control and RTC2/3 frames Telegram extension based on "Cut-through" Port status (Disabled, Blocking, Forwarding) Support for non-real-time and real-time data transfer |
Category: | Category 3 (EN ISO 13849) |
Scan angle: | 190 ° |
Electrical connection: | Copper conductor (2 female connectors for RJ-45 push-pull plug), system plug with or without connecting cable |
TM (mission time): | 20 a (EN ISO 13849) |
Port properties: | Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-TX |
Laser class: | 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) |
Enclosure rating: | IP 65 (EN 60529) |
Ambient operating temperature: | -10 °C ... +50 °C |
Number of field sets: | 4 |
Expanded measured data output (CMS): | - |