Sick S30A-6011EA
Laser Scanner, laser safety scanner , Sick Safety Sensors

Sick S30A-6011EA
  • Can only be used in EFI system network, e.g., with a Flexi Soft safety controller or another safety laser scanner
  • 5.5 m protective field range
  • Up to 32 switchable field sets
Item Number: S30A-6011EA
5270.26
-
+
Total price: 5270.26
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1023548
Electrical connection:System plug with or without connecting cable
Configuration and diagnostics interface:RS-232
Protective field range:5.5 m
Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
Number of monitoring cases:32
Number of multiple samplings:Configurable 2 ... 16
Weight:3.3 kg
Data interface:RS-422
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
TM (mission time):20 a (EN ISO 13849)
Measured data output:+
Number of static control inputs with EFI:5
Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable
Response time:60 ms
Number of application diagnostic outputs:3
Scan angle:190 °
Type of field set:Dual field sets, Triple field sets
Safe SICK device communication via EFI/SDL:+
Category:Category 3 (EN ISO 13849)
Number of reset-/restart inputs:1
Enclosure rating:IP 65 (EN 60529)
Dimensions (W x H x D):155 mm x 185 mm x 160 mm
Maximum warning field range:49 m
Integrated configuration memory:+
Performance level:PL d (EN ISO 13849)
External device monitoring (EDM):+
Number of safe outputs:2, Safety outputs (OSSD)
Distance measuring range:49 m
Protection class:II (EN 50178)
Number of EDM inputs:1
Access protection (vertical):+
Type:Type 3 (IEC 61496)
Hazardous area protection (horizontal):+
Hazardous area protection (vertical):+
Number of simultaneously monitored protective fields:≤ 4
PFHd:8.0 1E-08 (EN ISO 13849)
Expanded measured data output (CMS):-
Ambient operating temperature:-10 °C ... +50 °C
Static protective field switching:+
Maximum output current:500 mA
Incremental encoder inputs:+
Number of field sets:32