Sick S30A-6111CL
Safety laser scanner
We ship to United States of America!
- Direct integration in PROFINET IO safe bus system
- 5.5 m protective field range
- 4 switchable field sets
Item Number:
S30A-6111CL
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Specification:
Part Number | 1052593 |
Measured data output: | + |
Type of field set: | Dual field sets |
Number of simultaneously monitored protective fields: | 2 |
Expanded measured data output (CMS): | - |
Topology support: | SNMP, MIB-2, LLDP nach IEEE 802.1AB MRP client support |
Number of field sets: | 4 |
Safe SICK device communication via EFI/SDL: | - |
Electrical connection: | Optical fiber conductor (2 female connectors for SCRJ push-pull plug), system plug with or without connecting cable |
Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
Category: | Category 3 (EN ISO 13849) |
TM (mission time): | 20 a (EN ISO 13849) |
Supply voltage: | 16.8 V DC, 24 V DC, 28.8 V DC |
Hazardous area protection (horizontal): | + |
Number of multiple samplings: | Configurable 2 ... 16 |
Device properties: | GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc. |
Weight: | 3.3 kg |
Response time: | 60 ms |
Diagnostics: | Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable Report system errors Maintenance alerts for POF interfaces for signal quality Cable diagnostics Neighborhood alerts Support for port statistics I&M support from I&M0 to I&M4 |
Port properties: | Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-FX |
PFHd: | 8.0 1E-08 (EN ISO 13849) |
Incremental encoder inputs: | - |
Interfaces for configuration and diagnostics using CDS: | TCP port 9000 and UDP port 30718 RS-232 |
Number of monitoring cases: | 4 |
Static protective field switching: | + |
Integrated configuration memory: | + |
Maximum warning field range: | 49 m |
Switch properties: | Filtering Data Base according to IEEE 802.1D 6 prioritization levels for IEEE 802.1Q - Network prioritization 64 KB SRAM memory for caching telegrams, managed in 768-byte segments Resource prioritization for network control and RTC2/3 frames Telegram extension based on "Cut-through" Port status (Disabled, Blocking, Forwarding) Support for non-real-time and real-time data transfer |
Configuration and diagnostics interface: | RS-232 |
Conformance: | Conformance Class B |
Access protection (vertical): | + |
Laser class: | 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) |
Dimensions (W x H x D): | 155 mm x 185 mm x 160 mm |
Functions that are not supported: | Multicast communication Supervisor AR MAC-pause mechanism in full duplex Back-pressure in half duplex Static learning Broadcast Storm Control |
Ambient operating temperature: | -10 °C ... +50 °C |
Protective field range: | 5.5 m |
Performance level: | PL d (EN ISO 13849) |
Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable |
External device monitoring (EDM): | - |
Enclosure rating: | IP 65 (EN 60529) |
Type: | Type 3 (IEC 61496) |
Distance measuring range: | 49 m |
Scan angle: | 190 ° |
Protection class: | III (VDE 0106, EN 60950) |
Hazardous area protection (vertical): | + |
Buy Sick S30A-6111CL with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com is an electrical online store. We offer a full range of industrial automation equipment. Your order can be shipped with super fast delivery! Discover the best price in our web catalog. The offer submission date is always optimal for you. Safety, simplicity, and support during every stage.
People also buy
Comments
No comments yet