Sick S30A-6111DL
Laser Scanner, laser safety scanner , Sick Safety Sensors

Sick S30A-6111DL
  • Direct integration in PROFINET IO safe bus system
  • 5.5 m protective field range
  • 8 switchable field sets
Item Number: S30A-6111DL
7473.18
-
+
Total price: 7473.18
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1052594
Switch properties:Filtering Data Base according to IEEE 802.1D
6 prioritization levels for IEEE 802.1Q - Network prioritization
64 KB SRAM memory for caching telegrams, managed in 768-byte segments
Resource prioritization for network control and RTC2/3 frames
Telegram extension based on "Cut-through"
Port status (Disabled, Blocking, Forwarding)
Support for non-real-time and real-time data transfer
Access protection (vertical):+
Static protective field switching:+
Protection class:III (VDE 0106, EN 60950)
Number of field sets:8
Distance measuring range:49 m
Hazardous area protection (vertical):+
Type:Type 3 (IEC 61496)
Performance level:PL d (EN ISO 13849)
Safe SICK device communication via EFI/SDL:-
Integrated configuration memory:+
Topology support:SNMP, MIB-2, LLDP nach IEEE 802.1AB
MRP client support
Hazardous area protection (horizontal):+
External device monitoring (EDM):-
Number of multiple samplings:Configurable 2 ... 16
Protective field range:5.5 m
Expanded measured data output (CMS):-
Weight:3.3 kg
Category:Category 3 (EN ISO 13849)
Device properties:GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc.
Interfaces for configuration and diagnostics using CDS:TCP port 9000 and UDP port 30718
RS-232
Response time:60 ms
Functions that are not supported:Multicast communication
Supervisor AR
MAC-pause mechanism in full duplex
Back-pressure in half duplex
Static learning
Broadcast Storm Control
Port properties:Auto-negotiation
Auto-crossover (MDIX)
Auto-polarity
100Base-FX
Conformance:Conformance Class B
Incremental encoder inputs:-
Enclosure rating:IP 65 (EN 60529)
PFHd:8.0 1E-08 (EN ISO 13849)
Type of field set:Dual field sets
Dimensions (W x H x D):155 mm x 185 mm x 160 mm
TM (mission time):20 a (EN ISO 13849)
Measured data output:+
Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
Scan angle:190 °
Diagnostics:Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable
Report system errors
Maintenance alerts for POF interfaces for signal quality
Cable diagnostics
Neighborhood alerts
Support for port statistics
I&M support from I&M0 to I&M4
Ambient operating temperature:-10 °C ... +50 °C
Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Electrical connection:Optical fiber conductor (2 female connectors for SCRJ push-pull plug), system plug with or without connecting cable
Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable
Number of simultaneously monitored protective fields:2
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Maximum warning field range:49 m
Number of monitoring cases:16
Configuration and diagnostics interface:RS-232

Comments

No comments yet

Write a comment