Sick S30A-7011BA
Laser Scanner, laser safety scanner , Sick Safety Sensors
We ship to United States of America!
- 7 m protective field range
- 1 field set
- EFI interface for safe SICK device communication
Item Number:
S30A-7011BA
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Specification:
Part Number | 1023890 |
Safe SICK device communication via EFI/SDL: | + |
Maximum output current: | 500 mA |
Number of simultaneously monitored protective fields: | ≤ 4 |
Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
Integrated configuration memory: | + |
Distance measuring range: | 49 m |
Performance level: | PL d (EN ISO 13849) |
Maximum warning field range: | 49 m |
Scan angle: | 190 ° |
Configuration and diagnostics interface: | RS-232 |
Protection class: | II (EN 50178) |
Number of safe outputs: | 2, Safety outputs (OSSD) |
Weight: | 3.3 kg |
Number of reset-/restart inputs: | 1 |
Measured data output: | + |
Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable |
Number of multiple samplings: | Configurable 2 ... 16 |
Hazardous area protection (vertical): | + |
Electrical connection: | System plug with or without connecting cable |
Expanded measured data output (CMS): | - |
Type of field set: | Dual field sets, Triple field sets |
Category: | Category 3 (EN ISO 13849) |
External device monitoring (EDM): | + |
Number of EDM inputs: | 1 |
Ambient operating temperature: | -10 °C ... +50 °C |
Data interface: | RS-422 |
Dimensions (W x H x D): | 155 mm x 185 mm x 160 mm |
Enclosure rating: | IP 65 (EN 60529) |
Laser class: | 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) |
Supply voltage: | 16.8 V DC, 24 V DC, 28.8 V DC |
Incremental encoder inputs: | - |
Type: | Type 3 (IEC 61496) |
Number of field sets: | 1 |
Access protection (vertical): | + |
Protective field range: | 7 m |
PFHd: | 8.0 1E-08 (EN ISO 13849) |
TM (mission time): | 20 a (EN ISO 13849) |
Number of application diagnostic outputs: | 3 |
Response time: | 60 ms |
Hazardous area protection (horizontal): | + |
Static protective field switching: | - |
Number of monitoring cases: | 1 |
Buy Sick S30A-7011BA with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com offers industrial control components. A lot of in-stock parts, contact us to check availability. If you need to receive your order as soon as possible, we can provide express delivery. We always guarantee high-quality products. Our team of experts will find the best sales prices for you. We always fulfill our obligations.
People also buy
Comments
No comments yet