Sick S30A-7111CP
Laser Scanner, laser safety scanner , Sick Safety Sensors

Sick S30A-7111CP
  • Direct integration in PROFINET IO safe bus system
  • 7 m protective field range
  • 4 switchable field sets
Item Number: S30A-7111CP
6546.54
-
+
Total price: 6546.54
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1045654
Distance measuring range:49 m
Number of field sets:4
Number of multiple samplings:Configurable 2 ... 16
Performance level:PL d (EN ISO 13849)
Port properties:Auto-negotiation
Auto-crossover (MDIX)
Auto-polarity
100Base-TX
Access protection (vertical):+
Integrated configuration memory:+
Conformance:Conformance Class B
Scan angle:190 °
Hazardous area protection (vertical):+
Type:Type 3 (IEC 61496)
Protective field range:7 m
Switch properties:Filtering Data Base according to IEEE 802.1D
6 prioritization levels for IEEE 802.1Q - Network prioritization
64 KB SRAM memory for caching telegrams, managed in 768-byte segments
Resource prioritization for network control and RTC2/3 frames
Telegram extension based on "Cut-through"
Port status (Disabled, Blocking, Forwarding)
Support for non-real-time and real-time data transfer
Maximum warning field range:49 m
Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable
Category:Category 3 (EN ISO 13849)
Topology support:SNMP, MIB-2, LLDP nach IEEE 802.1AB
MRP client support
Safe SICK device communication via EFI/SDL:-
Ambient operating temperature:-10 °C ... +50 °C
Weight:3.3 kg
Type of field set:Dual field sets
Static protective field switching:+
Incremental encoder inputs:-
Number of simultaneously monitored protective fields:2
Configuration and diagnostics interface:RS-232
Enclosure rating:IP 65 (EN 60529)
Dimensions (W x H x D):155 mm x 185 mm x 160 mm
Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Number of monitoring cases:4
PFHd:8.0 1E-08 (EN ISO 13849)
Protection class:III (VDE 0106, EN 60950)
Diagnostics:Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable
Report system errors
Cable diagnostics
Neighborhood alerts
Support for port statistics
I&M support from I&M0 to I&M4
Measured data output:+
External device monitoring (EDM):-
Electrical connection:Copper conductor (2 female connectors for RJ-45 push-pull plug), system plug with or without connecting cable
Functions that are not supported:Multicast communication
Supervisor AR
MAC-pause mechanism in full duplex
Back-pressure in half duplex
Static learning
Broadcast Storm Control
Interfaces for configuration and diagnostics using CDS:TCP port 9000 and UDP port 30718
RS-232
TM (mission time):20 a (EN ISO 13849)
Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
Response time:60 ms
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Device properties:GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc.
Expanded measured data output (CMS):-
Hazardous area protection (horizontal):+

Comments

No comments yet

Write a comment