Sick TR110-SLUSA00
Safety locking device
We ship to United States of America!
TR110-SLUSA00 TRANSPONDER SAFETY SWITCH art. 6034589
Item Number:
TR110-SLUSA00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Sick TR110-SLUSA00
Datasheet:
- Article: 6034589
- Sensor operating principle: Transponder
- Locking principle: Normally open circuit principle
- Coding: Uniquely coded
- Starter force: ? 10 N
- Holding force: 20 N
- Unlocking force: ? 20 N
- Starter frequency: ? 0, 5 Hz
- Startup speed: ? 20 m/min
- Reliability class: SIL3 (IEC 61508), SILCL3 (EN 62061),
- Category: Category 4 (EN ISO 13849)
- Performance level: PL e (EN ISO 13849)
- PFHd (average probability of dangerous failure per hour): 4.1 x 10-9< /sup> (EN ISO 13849)
- TM (specified service life): 20 years (EN ISO 13849)
- Design type: Design type 4 (EN ISO 14119)
- Starter coding degree: High coding degree (EN ISO 14119)
- Safe state in case of error: At least one safety semiconductor output (OSSD) is in the state AUS (OFF).
- Reliable daisy chain: No, only individual wiring (with diagnostics)
- Connection type: M12 connector, 8-pin.
- Diagnostic indication: ?
- Status indication: ?
- Protection class: III (IEC 61140)
- Pollution degree: 3 (EN 60947-1) li>
- cULus classification: Class 2
- Consumption category: DC-13 (IEC 60947-5-1)
- Rated operating current (rated operating voltage): 150 mA (24 V DC), ,
- Rated insulation voltage Ui: 50 V
- Maximum permissible impulse voltage Uimp : 500 V
- Output type: Semiconductor outputs (OSSD) with self-monitoring
- Magnet power consumption: 6 W
- Magnet on-time: 100%
- Rating: ? 260 ms
- Unlock time: 400 ms
- On delay: 1 s
- Divergence time: ? 10 ms (EN IEC 60947- 5-3)
- Locking principle: Normally open circuit principle
- Weight: 0.42 kg
- Lifetime of mechanical components: 1 x 106 operation cycles
- Protection type: IP67 (EN 60529), IP69K,
- Operating temperature range: –20 °C ... +55 °C
- Vibration resistance: 10 Hz ... 55 Hz (IEC 60068-2-6)
- Shock resistance: 30 g, 11 ms (EN 60068-2-27)
- EMC : EN IEC 60947-5-3
- With direct starter: 3,900 N (EN ISO 14119)
- With angle starter: 1,500 N (EN ISO 14119)
- With hinged starter: 2,600 N (EN ISO 14119)
- With direct starter: 3,000 N (EN ISO 14119)
- With angle starter: 1,100 N (EN ISO 14119)
- With hinged starter: 2,000 N (EN ISO 14119)
- Sensor: 24 V DC (20.4 V DC ... 27.6 V DC)
- Magnet: 24 V DC (20.4 V DC ... 26.4 V DC)
- Sensor: 40 mA
- Magnet: 400 mA
- Safety-compatible outputs: 2 semiconductor outputs (output switching devices), p-switched, short-circuit-proof
- Diagnostic outputs: P-switched, short-circuit-proof
- Safety-supported outputs: 1 mA ... 150 mA
- Diagnostic outputs: 1 mA ... 50 mA
- Switch head: Zinc die-casting
- Housing: Fiberglass reinforced thermoplastic
- Connectors: Nickel-plated brass
- Series:TR110 Lock
- Category:Safety locking devices
- Output type: semiconductor
- Type of connector: M12
- Connection type: connector
Buy Sick TR110-SLUSA00 with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. provides complete industrial automation solutions. With a wide selection of products and efficient delivery options, we meet your needs effectively. Our focus on quality and customer satisfaction distinguishes us. Experience our exceptional service and support for your automation needs.
People also buy
Comments