Sick TR110-SRUCA00
Safety locking device
We ship to United States of America!
TR110-SRUCA00 TRANSPONDER SAFETY SWITCH art. 6044635
Item Number:
TR110-SRUCA00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Sick TR110-SRUCA00
Datasheet:
- Article: 6044635
- Sensor operating principle: Transponder
- Locking principle: Normally closed circuit principle
- Coding: Uniquely coded
- Starter force: ? 10 N
- Holding force: 20 N
- Unlocking force: ? 20 N
- Starter frequency: ? 0, 5 Hz
- Startup speed: ? 20 m/min
- Reliability class: SIL3 (IEC 61508), SILCL3 (EN 62061),
- Category: Category 4 (EN ISO 13849)
- Performance level: PL e (EN ISO 13849)
- PFHd (average probability of dangerous failure per hour): 4.1 x 10-9< /sup> (EN ISO 13849)
- TM (specified service life): 20 years (EN ISO 13849)
- Design type: Design type 4 (EN ISO 14119)
- Starter coding degree: High coding degree (EN ISO 14119)
- Safe state in case of error: At least one safety semiconductor output (OSSD) is in the state AUS (OFF).
- Reliable series circuit: With tee (no diagnostics)
- Connection type: M12 connector, 8-pin, M12 plug connector, 5-pin. ,
- Diagnostic display: ?
- Status display: ?
- Protection class: III (IEC 61140)
- Pollution degree: 3 ( EN 60947-1)
- cULus classification: Class 2
- Consumption category: DC-13 (IEC 60947-5-1)
- Rated operating current ( rated operating voltage): 150 mA (24 V DC),
- Rated insulation voltage Ui: 50 V
- Maximum permissible impulse voltage U< sub>imp: 500 V
- Output type: Semiconductor outputs (OSSD) with self-monitoring
- Magnet power consumption: 6 W
- Magnet on duration : 100%
- Rating: ? 260 ms
- Unlock time: 400 ms
- On delay: 8 s
- Divergence time: ? 10 ms (EN IEC 60947-5-3)
- Closing principle: Normally closed circuit principle
- Weight: 0.42 kg
- Service life of mechanical components: 1 x 106 actuation cycles
- Protection type: IP67 (EN 60529), IP69K,
- Operating temperature range: –20 °C ... + 55 °C
- Vibration resistance: 10 Hz ... 55 Hz (IEC 60068-2-6)
- Shock resistance: 30 g, 11 ms (EN 60068-2-27)
- EMC: EN IEC 60947-5-3
- With direct starter: 3,900 N (EN ISO 14119)
- With angle starter: 1,500 N (EN ISO 14119 )
- With hinged starter: 2,600 N (EN ISO 14119)
- With direct starter: 3,000 N (EN ISO 14119)
- With angle starter: 1,100 N (EN ISO 14119)
- With hinged starter: 2,000 N (EN ISO 14119)
- Sensor: 24 V DC (20.4 V DC ... 27.6 V DC)
- Magnet: 24 V DC (20.4 V DC ... 26.4 V DC)
- Sensor: 40 mA
- Magnet: 400 mA
- Safety-compatible outputs: 2 semiconductor outputs (output switching devices), p-switchable, short-circuit protected
- Diagnostic outputs: P-switched, short-circuit protected circuits
- Safety-supported outputs: 1 mA ... 150 mA
- Diagnostic outputs: 1 mA ... 50 mA
- Switch head: Zinc die-cast under pressure
- Housing: Thermoplastic, fiberglass reinforced
- Connectors: Nickel-plated brass
- Series: TR110 Lock
- Category:Safety locking devices
- Output type: semiconductor
- Type of connector :M12
- Connection type: connector
Buy Sick TR110-SRUCA00 with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com offers a comprehensive range of industrial electrical products. We specialize in sourcing and delivering hard-to-find parts promptly. Our commitment to quality and competitive pricing makes us a preferred supplier. Partner with us for reliable and efficient electrical supply solutions.