Sick TR110-SRUCA01
Safety locking device

Sick TR110-SRUCA01
We ship to United States of America!
TR110-SRUCA01 TRANSPONDER SAFETY SWITCH art. 6068075
Item Number: TR110-SRUCA01
1387.09
-
+
Total price: 1387.09
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick TR110-SRUCA01

Datasheet:

  • Article: 6068075
  • Sensor operating principle: Transponder
  • Locking principle: Normally closed circuit principle
  • Coding: Uniquely coded
  • Starter force: ? 10 N
  • Holding force: 20 N
  • Unlocking force: ? 20 N
  • Starter frequency: ? 0, 5 Hz
  • Start-up speed: ? 20 m/min
  • Supply set: Including release extension for evacuation
  • Safety class: SIL3 (IEC 61508), SILCL3 ( EN 62061),
  • Category: Category 4 (EN ISO 13849)
  • Performance level: PL e (EN ISO 13849)
  • PFHd (medium probability of dangerous failure per hour): 4.1 x 10-9 (EN ISO 13849)
  • TM (specified operating time): 20 years (EN ISO 13849)
  • Design type: Design type 4 (EN ISO 14119)
  • Starter coding degree: High coding degree (EN ISO 14119)
  • Safe condition in case of error occurs: At least one semiconductor safety output (OSSD) is in the AUS state (OFF).
  • Escape release: ?
  • Reliable sequential circuit: With tee (no diagnostics) )
  • Connection type: M12 connector, 8-pin, M12 plug connector, 5-pin,
  • Diagnostic display: ?
  • Status display: ?
  • Protection class: III (IEC 61140)
  • Pollution degree: 3 (EN 60947-1)
  • cULus classification: Class 2
  • li>Consumption category: DC-13 (IEC 60947-5-1)
  • Rated operating current (rated operating voltage): 150 mA (24 V DC), ,
  • Rated voltage on insulation Ui: 50 V
  • Maximum permissible pulse voltage Uimp: 500 V
  • Output type: Semiconductor outputs ( OSSD) with self-monitoring
  • Magnet power consumption: 6 W
  • Magnet on-time: 100%
  • Rating: ? 260 ms
  • Time unlocking: 400 ms
  • On delay: 8 s
  • Divergence time: ? 10 ms (EN IEC 60947-5-3)
  • Locking principle: Normal principle closed circuit
  • Weight: 0.42 kg
  • Mechanical component life: 1 x 106 operation cycles
  • Protection type: IP67 (EN 60529), IP69K,
  • Operating temperature range: –20 °C ... +55 °C
  • Vibration resistance: 10 Hz ... 55 Hz (IEC 60068- 2-6)
  • Shock resistance: 30 g, 11 ms (EN 60068-2-27)
  • EMC: EN IEC 60947-5-3
  • C direct starter: 3,900 N (EN ISO 14119)
  • With angle starter: 1,500 N (EN ISO 14119)
  • With hinged starter: 2,600 N (EN ISO 14119)
  • With direct starter: 3,000 N (EN ISO 14119)
  • With angle starter: 1,100 N (EN ISO 14119)
  • With hinged starter: 2,000 N (EN ISO 14119)
  • Sensor: 24 V DC (20.4 V DC ... 27.6 V DC)
  • Magnet: 24 V DC (20.4 V DC ... 26.4 V DC)
  • Sensor: 40 mA
  • Magnet: 400 mA
  • Safety outputs: 2 semiconductor outputs (output switching devices), p-switchable, short-circuit protected
  • Diagnostic outputs: P-switched, short-circuit protected
  • Safety-supported outputs: 1 mA ... 150 mA
  • Diagnostic outputs: 1 mA ... 50 mA
  • Switch head: Zinc die-cast
  • Housing: Thermoplastic, glass fiber reinforced
  • Connectors : Nickel-plated brass
  • Series:TR110 Lock
  • Category:Security locking devices
  • Output type: semiconductor
  • Type of connector:M12
  • Type of connection: connector