Sick TR110-SRUCA01
Safety locking device

Sick TR110-SRUCA01
We ship to United States of America!
TR110-SRUCA01 TRANSPONDER SAFETY SWITCH art. 6068075
Item Number: TR110-SRUCA01
1387.09
-
+
Total price: 1387.09
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Sick TR110-SRUCA01

Datasheet:

  • Article: 6068075
  • Sensor operating principle: Transponder
  • Locking principle: Normally closed circuit principle
  • Coding: Uniquely coded
  • Starter force: ? 10 N
  • Holding force: 20 N
  • Unlocking force: ? 20 N
  • Starter frequency: ? 0, 5 Hz
  • Start-up speed: ? 20 m/min
  • Supply set: Including release extension for evacuation
  • Safety class: SIL3 (IEC 61508), SILCL3 ( EN 62061),
  • Category: Category 4 (EN ISO 13849)
  • Performance level: PL e (EN ISO 13849)
  • PFHd (medium probability of dangerous failure per hour): 4.1 x 10-9 (EN ISO 13849)
  • TM (specified operating time): 20 years (EN ISO 13849)
  • Design type: Design type 4 (EN ISO 14119)
  • Starter coding degree: High coding degree (EN ISO 14119)
  • Safe condition in case of error occurs: At least one semiconductor safety output (OSSD) is in the AUS state (OFF).
  • Escape release: ?
  • Reliable sequential circuit: With tee (no diagnostics) )
  • Connection type: M12 connector, 8-pin, M12 plug connector, 5-pin,
  • Diagnostic display: ?
  • Status display: ?
  • Protection class: III (IEC 61140)
  • Pollution degree: 3 (EN 60947-1)
  • cULus classification: Class 2
  • li>Consumption category: DC-13 (IEC 60947-5-1)
  • Rated operating current (rated operating voltage): 150 mA (24 V DC), ,
  • Rated voltage on insulation Ui: 50 V
  • Maximum permissible pulse voltage Uimp: 500 V
  • Output type: Semiconductor outputs ( OSSD) with self-monitoring
  • Magnet power consumption: 6 W
  • Magnet on-time: 100%
  • Rating: ? 260 ms
  • Time unlocking: 400 ms
  • On delay: 8 s
  • Divergence time: ? 10 ms (EN IEC 60947-5-3)
  • Locking principle: Normal principle closed circuit
  • Weight: 0.42 kg
  • Mechanical component life: 1 x 106 operation cycles
  • Protection type: IP67 (EN 60529), IP69K,
  • Operating temperature range: –20 °C ... +55 °C
  • Vibration resistance: 10 Hz ... 55 Hz (IEC 60068- 2-6)
  • Shock resistance: 30 g, 11 ms (EN 60068-2-27)
  • EMC: EN IEC 60947-5-3
  • C direct starter: 3,900 N (EN ISO 14119)
  • With angle starter: 1,500 N (EN ISO 14119)
  • With hinged starter: 2,600 N (EN ISO 14119)
  • With direct starter: 3,000 N (EN ISO 14119)
  • With angle starter: 1,100 N (EN ISO 14119)
  • With hinged starter: 2,000 N (EN ISO 14119)
  • Sensor: 24 V DC (20.4 V DC ... 27.6 V DC)
  • Magnet: 24 V DC (20.4 V DC ... 26.4 V DC)
  • Sensor: 40 mA
  • Magnet: 400 mA
  • Safety outputs: 2 semiconductor outputs (output switching devices), p-switchable, short-circuit protected
  • Diagnostic outputs: P-switched, short-circuit protected
  • Safety-supported outputs: 1 mA ... 150 mA
  • Diagnostic outputs: 1 mA ... 50 mA
  • Switch head: Zinc die-cast
  • Housing: Thermoplastic, glass fiber reinforced
  • Connectors : Nickel-plated brass
  • Series:TR110 Lock
  • Category:Security locking devices
  • Output type: semiconductor
  • Type of connector:M12
  • Type of connection: connector

Buy Sick TR110-SRUCA01 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is a global leader in industrial automation supply. Our extensive catalog includes top brands, with worldwide delivery and competitive pricing. We focus on customer satisfaction and reliability. Experience our exceptional service and support for all your automation needs.

Comments

No comments yet

Write a comment