Sick UE410-4RO3

Sick UE410-4RO3
  • Safety controllers
  • Flexi Classic, relay module, UE410-4RO3
Item Number: UE410-4RO3
358.80
-
+
Total price: 358.80
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number6026143
Number of enable current contacts:4 (13/14, 23/24, 33/34, 43/44)
Internal power consumption:≤ 3.2 W
Weight:186 g (± 5 %)
Connection type:Screw-type terminals
Enclosure rating terminals:IP 20 (EN 60529)
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Number of contactor monitoring contacts:2 (Y1/Y2, Y3/Y4)
Protection class housing:IP 40 (EN 60529)
Number of control inputs:2 (B1, B2)
Performance level:PL e (EN ISO 13849-1)
Ambient operating temperature:-25 °C ... +55 °C
Safe state in the event of a fault:The extension has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit.
Dimensions (W x H x D):22.5 mm x 96.5 mm x 120.6 mm
Storage temperature:-25 °C ... +70 °C
Number of signalling current contacts:2 (Y14, Y24)
Voltage supply:Via FLEXBUS+
Category:Category 4 (EN ISO 13849-1)
Overvoltage category:II (EN 61131-2)

Comments

No comments yet

Write a comment