WEU26/3-203A00S01 LIGHT RECEIVER art. 1089127
Item Number: WEU26/3-203A00S01
693.42
-
+
Total price: 693.42
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick WEU26/3-203A00S01

Datasheet:

  • Item number: 1089127
  • Scanning range: 70 m
  • Beam path length: 15 m ... 70 m
  • Number of beams: 1
  • Detection ability: 30 mm
  • Evaluation: ? 22 ms
  • Heated front glass: ?
  • Synchronization: Optical synchronization
  • Type: Type 4 (IEC 61496-1)
  • Reliability class: SIL3 (IEC 61508), SILCL3 (EN 62061),
  • Category: Category 4 (EN ISO 13849)
  • Performance level: PL e (EN ISO 13849)
  • B10d value: 1 x 106 actuation cycles , 2 x 105 operating cycles
  • PFHd (average probability of dangerous failure per hour): 4.0 x 10-9 (EN ISO 13849)
  • TM (targeted operating time): 20 years (EN ISO 13849)
  • Safe state in case of error: At least one OSSD output is in in AUS state (OFF).
  • Connection type: M12 connector, 8-pin.
  • Indication elements: LEDs
  • Protection class: I (EN 50178 )
  • Supply voltage UV: 24 V DC (19.2 V DC ... 28.8 V DC)
  • Power consumption: ? 8 W
  • On delay: ? 10 s
  • Discrete outputs: Relay
  • Housing type: Rectangular
  • Dimensions (W x H x D ): 50 mm x 156 mm x 116 mm
  • Case material: Die-cast aluminum
  • Front glass material: Polycarbonate, scratch-resistant
  • Weight: ? 1 kg
  • Protection type: IP67 (EN 60529)
  • Operating temperature range: –25 °C ... +55 °C
  • Storage temperature: –25 ° C ... +70 °C
  • Air humidity: 15% ... 95%, non-condensing
  • Vibration resistance: 5 g, 10 Hz ... 55 Hz (IEC 60068-2-6)
  • Shock resistance: 10 g, 16 ms (IEC 60068-2-29)
  • Integration via Flexi Soft safety controller: CANopen
  • : DeviceNet
  • : EtherCAT®
  • : EtherNet/IP
  • : Modbus TCP
  • : PROFIBUS DP
  • : PROFINET
  • Consumption category: AC-15/DC-13 (EN 60947-5-1)
  • Switching voltage: 10 V DC ... 30 V DC
  • : 10 V AC ... 230 V AC
  • Permissible current load of the output switching device: 0.02 A ... 2 A
  • Contact material: Gold-plated silver alloy
  • Electrical component life (relay contacts): ? 1 x 105 operating cycles
  • Mechanical service life components (relay contacts): ? 1 x 107 operation cycles
  • Category:Single beam safety light curtains
  • Series:WSU/WEU26-3