The Product is no Longer Available!
- 2 AS-Interface networks
- PROFIBUS DP V1 support
- Connection to PROFIBUS DP
- 2 AS-Interface networks
- PROFIBUS DP V1 support
- Easy commissioning and fault diagnosis via LEDs and graphic display
- Earth fault detection
- AS-Interface noise detection
- Connection to PROFIBUS DP
- 2 AS-Interface networks
- Integrated data decoupling
- PROFIBUS DP V1 support
- Easy commissioning and fault diagnosis via LEDs and graphic display
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Connection to PROFIBUS DP
- 2 AS-Interface networks
- PROFIBUS DP V1 support
- Easy commissioning and fault diagnosis via LEDs and graphic display
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Ethernet diagnostic interface
- Connection to PROFIBUS DP
- 2 AS-Interface networks
- PROFIBUS DP V1 support
- Easy commissioning and fault diagnosis via LEDs and graphic display
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Ethernet diagnostic interface
- Gateway compliant with AS-Interface specification 3.0
- Compact stainless steel housing
- 7-segment display of addresses and error messages
- Connection to PROFIBUS DP
- Commissioning, without PROFIBUS communication
- All AS-Interface functions possible via PROFIBUS
- Gateway and safety monitor in one housing
- Gateway compliant with AS-Interface specification 3.0
- Connection to PROFIBUS DP
- AS-Interface safety monitor with extended range of functions
- Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
- Memory card for configuration data
- 2 safe output relays and 2 safe electronic outputs
- Gateway and safety monitor in one housing
- Gateway compliant with AS-Interface specification 3.0
- Connection to PROFIBUS DP
- AS-Interface safety monitor with extended range of functions
- Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
- Memory card for configuration data
- 2 AS-Interface networks
- 2 safe output relays and 2 safe electronic outputs
- Gateway and safety monitor in one housing
- Connection to PROFIBUS DP
- SafeLink
- Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
- 2 AS-Interface networks
- 2 safe output relays and 2 safe electronic outputs
- Integrated data decoupling
- Diagnostics via RJ45 Ethernet port
- Gateway compliant with AS-Interface specification 3.0
- Connection to PROFINET IO
- Fault diagnosis via LEDs and grafic display
- Easy commissioning by graphic display
- AS-Interface monitor or extended AS-Interface diagnostic read via display
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- All AS-Interface functions possible via Ethernet
- Commissioning, locally on the gateway or via AS-i Control Tools software
- Ethernet diagnostic interface
- Gateway compliant with AS-Interface specification 3.0
- Connection to PROFINET IO
- Earth fault detection
- Fault diagnosis via LEDs and grafic display
- Compact stainless steel housing
- Connection to PROFINET IO
- Conformance Class B
- Easy commissioning by graphic display
- AS-Interface monitor or extended AS-Interface diagnostic read via display
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- All AS-Interface functions possible via Ethernet
- Ethernet diagnostic interface
- AS-Interface POWER24
- Connection to PROFINET IO
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Ethernet diagnostic interface
- 2 AS-Interface networks
- Integrated data decoupling
- Integrated webserver
- Integrated switch allows line topology
- Connection to PROFINET IO
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- 2 AS-Interface networks
- Integrated web server with extended functionality
- Integrated switch allows line topology
- Gateway compliant with AS-Interface specification 3.0
- AS-Interface safety monitor with extended range of functions
- Fulfills technical safety requirements up to SIL 3 / PLe
- Memory card for configuration data
- 2 AS-Interface networks
- 2 safe output relays and 2 safe electronic outputs
- Gateway and safety monitor in one housing
- Connection to PROFINET IO
- SafeLink
- Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
- 2 AS-Interface networks
- Six safe electronic outputs
- Integrated data decoupling
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Ethernet diagnostic interface
- Gateway and safety monitor in one housing
- Gateway compliant with AS-Interface specification 3.0
- Connection to PROFINET IO
- AS-Interface safety monitor with extended range of functions
- Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
- Memory card for configuration data
- 2 AS-Interface networks
- 2 safe output relays and 2 safe electronic outputs
- PROFIsafe protocol for centralized and secure higher-level control
- Stand alone master with PLC functionality and RS 232 interface
- Large, graphic LCD
- RS 232 diagnosis interface
- Easy commissioning and fault diagnosis via LEDs and graphic display
- Earth fault detection
- AS-Interface noise detection
- Gateway compliant with AS-Interface specification 3.0
- Commissioning, locally on the gateway or via AS-i Control Tools software
- AS-Interface scanner for CompactLogix or MicroLogix 1500 PLC
Festo VBNF
Festo VBNF
Festo VBOH
| Valve function | 3/2 double solenoid |
| Pneumatic connection, port 1 | G1/4 |
| Standard nominal flow rate (standardised to DIN 1343) | 1675 l/min |
| Grid dimension | 31 mm |
Festo VBOH
| Valve function | 3/2 double solenoid |
| Pneumatic connection, port 1 | G1/8 |
| Standard nominal flow rate (standardised to DIN 1343) | 777 l/min |
| Grid dimension | 24 mm |
- Addressing and programming AS-Interface slaves
- Displaying the assigned slave addresses and the status of the inputs
- Setting outputs at the AS-Interface slave
- Also supports profiles S-7.7.A.7 (Spec 3.0), S-0.B and S-7.B (AS Interface Safety at Work)
- The slave connection is short-circuit and overload proof
- Battery charger included with delivery
- Addressing and programming AS-Interface slaves
- Displaying the assigned slave addresses and the status of the inputs
- Setting outputs at the AS-Interface slave
- Also supports profiles S-7.7.A.7 (Spec 3.0), S-0.B and S-7.B (AS Interface Safety at Work)
- The slave connection is short-circuit and overload proof
- Battery charger included with delivery
- Addressing and programming AS-Interface slaves
- Displaying the assigned slave addresses and the status of the inputs
- Setting outputs at the AS-Interface slave
- Also supports profiles S-7.7.A.7 (Spec 3.0), S-0.B and S-7.B (AS Interface Safety at Work)
- The slave connection is short-circuit and overload proof
- Battery charger included with delivery
- Addressing and programming AS-Interface slaves
- Displaying the assigned slave addresses and the status of the inputs
- Setting outputs at the AS-Interface slave
- Also supports profiles S-7.7.A.7 (Spec 3.0), S-0.B and S-7.B (AS Interface Safety at Work)
- The slave connection is short-circuit and overload proof
- Battery charger included with delivery
- Four programming cables included VAZ-PK-1.5M-V1-G, V1S-G-1M-PUR, V1-G-0.3M-PUR-V1-G, and VAZ-PK-FK-0.2M-V1-W
- For use in North and South America