• Housing with removable terminals
  • Communication monitoring
  • Inputs for 2-wire sensors and mechanical contacts
  • Addressing jack
  • Power supply of the inputs and outputs from the external auxiliary voltage
  • Function display for bus, ext. auxiliary voltage, inputs and outputs
  • Housing with push-in connection technology and mechanically coded terminal blocks
  • Housing width 19 mm, installation in the switch cabinet on DIN mounting rail
  • Selectable supply to the sensors: External or from the module
  • Function display for bus, external auxiliary voltage, internal sensor supply, inputs, and outputs
  • Red LED per channel, lights up in the event of output overload
  • Housing with push-in connection technology and mechanically coded terminal blocks
  • Housing width 19 mm, installation in the switch cabinet on DIN mounting rail
  • Selectable supply to the sensors: External or from the module
  • Function display for bus, internal sensor supply, inputs, and outputs
  • Inputs for 2-, 3-, and 4-wire sensors
  • Supply of sensors from AS-Interface
  • Function display for bus and inputs
  • Degree of protection IP68 / IP69K
  • Communication monitoring
  • Cable piercing method with gold plated contact pins
  • AS-Interface POWER24
  • A/B slave with extended addressing possibility for up to 62 slaves
  • One-piece housing with stainless steel base
  • Installation without tools
  • Metal threaded inserts with SPEEDCON technology
  • Flat cable connection with cable piercing technique, variable flat cable guide
  • Communication monitoring, configurable
  • Inputs for 2-, 3-, and 4-wire sensors
  • DIN rail mounting
  • AS-Interface certificate
  • Automatic addressing with latest masters in the event of replacement
  • AS-Interface certificate
  • Degree of protection IP67
  • Flat or round cable connection (via standardized EMS base, not included with delivery)
  • Cable piercing method for flat cable
  • 2 integrated illuminated pushbuttons green red
  • Fault signal via LED
  • AS-Interface certificate
  • Degree of protection IP67
  • Flat or round cable connection (via standardized EMS base, not included with delivery)
  • Cable piercing method for flat cable
  • 2 integrated yellow illuminated pushbuttons
  • Fault signal via LED
Operating Temperature+2...+50°C
Pressure Increase Ratio2:4
Maximum Input Pressure1MPa

VBA10/11A

  • VBA10/11A
  • Booster Regulator
  • VBA40A
  • Booster Regulator
  • VBA2#A,4#A
  • Booster Regulator
  • VBA2#A,4#A
  • Booster Regulator
  • Gateway compliant with AS-Interface specification 3.0
  • Fault diagnosis via LEDs and grafic display
  • Easy commissioning by graphic display
  • AS-Interface monitor read via display
  • Earth fault detection
  • AS-Interface noise detection
  • Gateway and safety monitor in one housing
  • SafeLink
  • Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
  • Six safe electronic outputs
  • Integrated data decoupling
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • Connection to CC-Link
  • Gateway compliant with AS-Interface specification 3.0
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • Easy commissioning by graphic display
  • Commissioning, locally on the gateway or via AS-i Control Tools software
  • Fault diagnosis via LEDs and grafic display
  • AS-Interface monitor or extended AS-Interface diagnostic read via display
  • Ethernet diagnostic interface
  • Gateway compliant with AS-Interface specification 3.0
  • 2 AS-Interface networks
  • Earth fault detection
  • AS-Interface noise detection
  • Easy commissioning by graphic display
  • Commissioning, locally on the gateway or via AS-i Control Tools software
  • Fault diagnosis via LEDs and grafic display
  • AS-Interface monitor or extended AS-Interface diagnostic read via display
  • Gateway and safety monitor in one housing
  • Connection to EtherCAT
  • SafeLink
  • Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
  • 2 AS-Interface networks
  • Six safe electronic outputs
  • Integrated data decoupling
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • Gateway compliant with AS-Interface specification 3.0
  • Connection to Ethernet Modbus TCP/IP
  • Dublicate addressing detection
  • Integrated webserver
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • Integrated switch allows line topology
  • DLR technology supports ring topology
  • Connection to Ethernet Modbus TCP/IP
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • Integrated switch allows line topology
  • DLR technology supports ring topology
  • AS-Interface POWER24
  • Connection to Ethernet Modbus TCP/IP
  • 2 AS-Interface networks
  • Easy commissioning and fault diagnosis via LEDs and graphic display
  • Dublicate addressing detection
  • Integrated data decoupling
  • Integrated switch allows line topology
  • Integrated webserver
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • DLR technology supports ring topology
  • Gateway and safety monitor in one housing
  • Gateway compliant with AS-Interface specification 3.0
  • Connection to Ethernet Modbus TCP/IP
  • AS-Interface safety monitor with extended range of functions
  • Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
  • Memory card for configuration data
  • 2 AS-Interface networks
  • 2 safe output relays and 2 safe electronic outputs
  • Integrated switch allows line topology
  • DLR technology supports ring topology
  • Gateway compliant with AS-Interface specification 3.0
  • One AS-Interface network
  • Web-based configuration
  • Commissioning via mobile devices possible
  • IIoT-ready thanks to REST API
  • Multiprotocol capability for PROFINET and EtherNet/IP
  • Gateway compliant with AS-Interface specification 3.0
  • 2 AS-Interface networks
  • Web-based configuration
  • Commissioning via mobile devices possible
  • IIoT-ready thanks to REST API
  • Multiprotocol capability for PROFINET and EtherNet/IP
  • Connection to MODBUS RTU
  • Easy commissioning and fault diagnosis via LEDs and graphic display
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • RS 232 diagnosis interface
  • Connection to PROFIBUS DP
  • Easy commissioning and fault diagnosis via LEDs and graphic display
  • PROFIBUS DP V1 support
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • RS 232 diagnosis interface
  • Connection to PROFIBUS DP
  • PROFIBUS DP V1 support
  • Easy commissioning and fault diagnosis via LEDs and graphic display
  • Earth fault detection
  • AS-Interface noise detection
  • Connection to PROFIBUS DP
  • PROFIBUS DP V1 support
  • Easy commissioning and fault diagnosis via LEDs and graphic display
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • Connection to PROFIBUS DP
  • Easy commissioning and fault diagnosis via LEDs and graphic display
  • PROFIBUS DP V1 support
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection