TeSys F
main contact set
3P
The LAN-B-A 30 BG is a support bearing from Bosch Rexroth that is used to fix linear guides in industrial applications.
- 4-channel
- Power supply for 2-wire transmitters with 4 mA ... 20 mA
- Installation in Zone 2 or safe area
- Supply circuit 15 V (20 mA)
- Input from active signals of 4-wire transmitters
- HART communication via field bus or service bus
- Simulation mode for service operations (forcing)
- Line fault detection (LFD): one LED per channel
- Permanently self-monitoring
- Module can be exchanged under voltage
- 4-channel
- Power supply for 2-wire transmitters with 4 mA ... 20 mA
- Installation in Zone 2 or safe area
- Supply circuit 21.5 V (4 mA)
- HART communication via field bus or service bus
- Simulation mode for service operations (forcing)
- Line fault detection (LFD): one LED per channel
- Permanently self-monitoring
- Module can be exchanged under voltage
- 4-channel
- Inputs Ex ia
- Mounting in Zone 2, Class I/Div.2 or in the safe area
- Power supply for 2-wire transmitters with 4 mA ... 20 mA
- Supply circuit 15 V (20 mA)
- Input from active signals of 4-wire transmitters
- HART communication via field bus or service bus
- Simulation mode for service operations (forcing)
- Line fault detection (LFD): one LED per channel
- Permanently self-monitoring
- Module can be exchanged under voltage
- 4-channel
- Inputs Ex ia
- Mounting in Zone 2, Class I/Div.2 or in the safe area
- Power supply for 2-wire transmitters with 4 mA ... 20 mA
- Supply circuit 15 V (20 mA)
- HART communication via field bus or service bus
- Simulation mode for service operations (forcing)
- Line fault detection (LFD): one LED per channel
- Permanently self-monitoring
- Module can be exchanged under voltage
- 8-channel
- Outputs Ex ib
- Mounting in Zone 2, Class I/Div.2 or in the safe area
- Module can be exchanged under voltage
- Galvanic group isolation
- Line fault detection (LFD)
- Positive or negative logic selectable
- Simulation mode for service operations (forcing)
- Permanently self-monitoring
- Output with watchdog
- Output with bus-independent safety shutdown
- Interface between the I/O modules and the PCS/PLC
- Com unit for 80 analog or 184 digital channels
- Communication via MODBUS RTU
- Mounting in Zone 2, Class I/Div.2 or in the safe area
- HART communication via service bus
- Configuration via FDT 1.2 DTM
- Non-volatile memory for configuration and parameter settings
- Self configuration in redundant systems
- Permanently self-monitoring
- Outputs drive to safe state in case of failures
- Module can be exchanged under voltage
- Interface between the I/O modules and the PCS/PLC
- Com unit for 80 analog or 184 digital channels
- Communication via PROFIBUS DP
- Mounting in Zone 2, Class I/Div.2 or in the safe area
- HART communication via PROFIBUS DP V1 or service bus
- Configuration via FDT 1.2 DTM
- Configuration in run (CiR) for any PCS
- Non-volatile memory for configuration and parameter settings
- Self configuration in redundant systems
- Permanently self-monitoring
- Outputs drive to safe state in case of failures
- Module can be exchanged under voltage
- Interface between the I/O modules and the PCS/PLC
- Com unit for 80 analog or 184 digital channels
- Communication via PROFIBUS DP
- Mounting in Zone 2, Class I/Div.2 or in the safe area
- HART communication via PROFIBUS DP V1 or service bus
- Configuration via FDT 1.2 DTM
- Configuration in run (CiR) for any PCS
- Non-volatile memory for configuration and parameter settings
- Self configuration in redundant systems
- Permanently self-monitoring
- Outputs drive to safe state in case of failures
- Module can be exchanged under voltage
- Interface between the I/O modules and the PCS/PLC
- Com unit for 80 analog or 184 digital channels
- Communication via MODBUS TCP
- Mounting in Zone 2, Class I/Div.2 or in the safe area
- HART communication via MODBUS TCP or service bus
- Configuration via FDT 1.2 DTM
- Non-volatile memory for configuration and parameter settings
- Self configuration in redundant systems
- Permanently self-monitoring
- Outputs drive to safe state in case of failures
- Module can be exchanged under voltage
- Interface between the I/O modules and the PCS/PLC
- Mounting in Zone 2, Class I/Div.2 or in the safe area
- Non-volatile memory for configuration and parameter settings
- Communication via PROFINET
- HART communication via PROFINET and HART I/P
CleverLevel LBFS-01111.0
- Point level detection based on frequency sweep technology
- Reliable in diverse media
- Wide variety of process connections
- For hygienic and industrial applications
The LC25DB40D7X is a logic cartridge valve from Bosch Rexroth that is used in hydraulic systems to control fluid flow. It is a member of the LC25 series, which is characterized by high performance, reliability and a wide range of applications.
3P(3NO)
AC-3/AC-3e
<=440V
115A, 24V DC standard coil
screw clamp terminals
3P - AC-3 440V
25A
24Vac coil
3P(3 NO), AC-3/AC-3e
0 to 440V
25A
250VAC 50/60Hz coil
3P(3 NO), AC-3/AC-3e
0 to 440V
65A
24VDC standard coil
9 A, 3 P, 5 HP at 480 VAC
reversing
120 VAC 50/60 Hz coil
The LC100A10E6X from Bosch Rexroth is a logic inline valve with a size of 100. It is bi-directional, which means that the flow can go from A to B or from B to A. The valve is hydraulically actuated and uses a type AE piston
The LC80A20D6X V from Bosch Rexroth is a 4-way logic cartridge valve designed for industrial hydraulic applications requiring reliable bidirectional flow switching. Part of Bosch Rexroth's high-performance AD coil valve range, this valve features hydraulic control for precise control of the direction of oil flow.
| Type | CAPACITOR |
| Weight | 2 kg |
| Type | CAPACITOR |
| Weight | 2 kg |
Detects water content in oil and air
- LEFB Electric Actuator
- Slider Type
- Belt Drive
- LEHZ
- Electric Gripper
- 2 Finger
- Vertical Type
- LER
- Electric Rotary Table
Levelflex FMP57-5JW5/0, LC=4000мм
- Type: Levelflex FMP57
- Probe: rope, 35 m
- Output signal: 4-20 mA HART