• No unusable area

  • 5 mm flush

  • Use of standard metallic actuating surfaces

schneider nsx100h

  • Ambient temperature: -25°C to +50°C
  • Relative humidity: up to 95% (non-condensing)
  • Vibration: vibration resistant according to IEC 60068-2-6


nsx 125a

  • Control type: Manual
  • Control mechanism: Lever
  • Indication: Flag position indicator
  • Auxiliary contacts: 2 NO + 2 NC (optional)
  • Signal contacts: 1 NO + 1 NC (optional)
  • Motor drive: Yes (optional)

nsx 160 n

  • Maximum operating voltage: 750 V AC 50/60 Hz
  • Maximum current: 175 А
  • Short-term current withstand: 1600 А
  • Mechanical wear resistance: 10,000 WO cycles

nsx 160a

  • Rated insulation voltage: 800 V AC
  • Overcurrent control current range of the overload disconnector: 63-160 А
  • Short-circuit sensitivity limit: 36 kA

nsx 160f

  • Rated insulation voltage (Ui): 800 V AC
  • Rated operating voltage (Ue): 690 V AC
  • Heat resistance limit: 120°C
  • Rated short-circuit current (Icu): 36 kA

nsx 200a

  • Rated breaking capacity (Icu): 10 kA at 400 VAC
  • Peak breaking capacity (Icu): 20 kA at 400 VAC
  • Current limit characteristic (Ics): 12 kA at 400 VAC

nsx 250a

Operating voltage:

  • AC: 415 V (phase-neutral), 690 V (phase-to-phase)
  • DC: 220 V

schneider nsx250n

  • Rated voltage: 415 V AC
  • Frequency: 50 Hz
  • Electromagnetic compatibility: IEC/EN 61000-6-1, IEC/EN 61000-6-3
  • Resistance to short-circuit currents: 50 kA (symmetrical)

nsx 400a schneider

  • Rated voltage: 400 V AC / 690 V DC
  • Frequency: 50/60 Hz
  • Short circuit current limit: 18 kA
  • Peak short-circuit current: 50 kA
  • Operating frequency: 0.5 Hz
  • Electrical wear resistance: CO 6,000

nsx 63a

  • Operating temperature range: from -25°C to +50°C
  • Vibration resistance: according to IEC 60068-2-6
  • Impact resistance: according to IEC 60068-2-7

nsx 800a

  • Operating temperature range: -25°C to +70°C
  • Vibration resistance: Up to 10 GN/m2
  • Impact resistance: 15 J
  • Compliance with standards: IEC 60947-2, GB 14048.1

nsx 80a

  • Rated voltage: 230/400 V AC
  • Overload class: 3
  • Degree of protection: IP40

nsx mccb

  • Ambient temperature: -25°C to +55°C
  • Altitude above sea level: up to 2000 m
  • Vibration and shock resistance
  • Resistance to electromagnetic interference (EMI)

nsx100 micrologic 2.2

  • Rated voltage: 230/400 V AC
  • Rated frequency: 50/60 Hz
  • Thermal decoupling limit: 1.1 In - 1.35 In
  • Short-circuit current limit: 3 ... 14 x In (short-term)
  • Electromagnetic release limit: 50 ... 100 x In (instantaneous)
  • Power loss: < 0.7 W (at rated current)
  • Degree of protection: IP40

nsx100b tm100d

  • Operating temperature range: -25°C to +55°C
  • Storage temperature: -40°C to +70°C
  • Mounting: on a DIN rail or panel

nsx100b tm63d

  • Short-circuit current limit (Icu): 100 kA
  • Thermal overcurrent limit (Ith): 63 А
  • Dynamic sustained short-circuit current limit (Ics): 65 kA

nsx100b tm80d

  • Ambient temperature: -25°C to +50°C
  • Vibration resistance: up to 3 GHz
  • Impact resistance: up to 15 G (IEC 60068-2-7)
  • Mounting: On DIN rail or panel

schneider nsx100f

  • Rated operating frequency: 50/60 Hz
  • Thermal release limit: 85°C
  • Operating temperature limit: -25°C to +70°C
  • Storage temperature limit: -40°C to +80°C
  • Electrical resistance: 500 V AC/DC
  • Mechanical resistance: withstands shocks up to 7 g

nsx100f 100a

  • Rated operating frequency: 50/60 Hz
  • Short-circuit current limit (Icu): 1 kA
  • Short-circuit current limit (Ics): 36 kA
  • Rated power: 22 kW (AC-1) / 44 kW (AC-3)

nsx100f 3p

  • Rated operating frequency: 50/60 Hz
  • Resistance to short-circuit currents: 36 kA (at 415 V AC)
  • Maximum power loss: 23 W (at 100 A)
  • Insulation voltage: 800 V AC

nsx100f 40a

  • Maximum short-circuit current (Icu): 36 kA
  • Limit short-circuit current (Ics): 150% Icu for 0.5 s
  • Thermal disconnection current: 50 А
  • Rated voltage: 400 V AC
  • Frequency: 50/60 Hz
  • Voltage drop: 0.75% at rated current
  • Switching class: AC-2, AC-3, DC

nsx100f 4p

  • Thermal disconnection class: A
  • Maximum permissible ambient temperature: +40°C
  • Short-circuit current resistance: 10 kA at 600 VAC (IEC 60947-2)

nsx100f 63a

  • Frequency: 50/60 Hz
  • Maximum operating temperature: 40°C
  • Minimum operating temperature: -25°C
  • Maximum mechanical endurance: 1000 impacts/hour, 15 g

nsx100f mccb

  • Type of disconnection mechanism: two-contact, double break
  • Disconnection speed: 200 ms (typical)
  • Connection speed: 150 ms (typical)

nsx100f micrologic 2.2

  • Frequency: 50/60 Hz
  • Thermal decoupling limit: From 1.05 to 1.3 In (depending on the model)
  • Short circuit current limit: 3.5 In (depending on the model)

nsx100f tm100d

  • Degree of protection: IP40
  • Vibration resistance: 3 g/mm (5 Hz - 300 Hz)
  • Impact resistance: 50 g/mm (11 ms)

nsx100f tm16d

  • Insulation: 2000 V between channels
  • Vibration resistance: 5 g (10 Hz - 500 Hz)
  • Shock resistance: 50 g/0.5 ms
  • Mounting: on DIN rail or panel

nsx100f tm25d

  • Vibration resistance: 5 g (up to 2 GHz)
  • Shock resistance: 8 g (11 ms)
  • Resistance to electromagnetic interference: IEC 60947-2