| Voltage supply | 5 VDC ±5 % 8...30 VDC |
| Reverse polarity protection | Yes |
| Consumption w/o load | ≤100 mA |
| Operating temperature | -20...+70 °C -20...+100 °C |
Incremental encoders
- Max. 10000 pulses per revolution
- Optical sensing method
- Through hollow shaft
- Mounting by torque support
- TTL or HTL output signals
Baumer incremental miniature encoder.
Incremental optical encoder by Baumer ITD 4 A 4 with blind hollow shaft.
10 mm (through the hollow shaft), 12 mm (through the hollow shaft), 14 mm (through the hollow shaft)
art. 11063147
Incremental encoder with hollow shaft, detachable cable – tangential outlet and wide operating temperature range.
ITD21H00 2048 T NI S21SG8 E 14 IP65
Incremental encoder with hollow shaft, detachable cable – tangential outlet and wide operating temperature range.Catalogue number 11063146.
- Resolution 512ppr pulses / revolution
- 14mm shaft bore diameter
- 1 x digital output 8-30Vdc
art. 11106854
- ITV1000/2000/3000
- Electro-Pneumatic Regulator
Cylinder type: 2-stage telescopic cylinder
USB converter unit with copy and backup function.
Pneumatic cylinder with stainless steel piston rod.
- Stroke length: 125mm
- Temperature: -20C … 80C
- Pressure: 1,5…10bar
KFD2 CD2 EX1
- Marking: space for marking on the front panel
- Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013 (industrial premises)
- Degree of protection: IEC 60529:2001
- Protection against electric shock: UL 61010-1:2004
- Ambient temperature: -20...60 °C (-4...140 °F)
KFD2 CD2 EX2
- Maximum current consumption: 100 mA
- Response time: < 250 ms
- Overcurrent protection: Yes
- Short circuit protection: Yes
- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- Level sensing input
- Adjustable range 1 k Omega- ... 150 k Omega-
- Relay contact output
- Fault relay contact output
- Adjustable time delay up to 10 s
- Minimum/maximum control
- Line fault detection (LFD)
KFD2 GU 1
- Resolution: 0.1°C or 0.1°F
- Overload: 150% of the measurement range within 2 seconds
- Short Circuit: The output is protected against short circuits to power and ground
- Input resistance: RTD: ≤ 20 ohms
- Thermocouple: ≤ 2 MΩ
- Output resistance: ≤ 2 ohms
- 2-channel signal conditioner
- 24 V DC supply (Power Rail)
- Current output up to 700 Omega- load
- HART I/P and valve positioner
- Line fault detection (LFD)
- Accuracy 0.05 %
- Terminal blocks with test sockets
- Up to SIL 2 acc. to IEC 61508
- 2-channel isolated barrier
- 24 V DC supply (Power Rail)
- Dry contact or NAMUR inputs
- Usable as signal splitter (1 input and 2 outputs)
- 2 x 2 relay contact outputs with AND logic
- Line fault detection (LFD)
- Reversible mode of operation
- Up to SIL 2 acc. to IEC 61508
KFD2 STC4 2
- Connection: Screw terminals
- Mounting: On a 35 mm DIN rail according to EN 60715: 2001
- EC type conformity certificate: BAS 99 ATEX 7025 X
- Certificate: TÜV 99 ATEX 1499 X
- IECEx certificate: IECEx BAS 04.0015X IECEx CML 15.0055X
- 2-channel isolated barrier
- 24 V DC supply (Power Rail)
- Input 2-wire SMART transmitters
- Output 0/4 mA ... 20 mA current sink
- Terminal blocks with test sockets
- Up to SIL 2 acc. to IEC 61508
KFD2 STV4 EX2 2
- Input Impedance: Approx. 200 ohms
- Maximum input voltage: 30 V
- Reverse polarity protection: Built-in protection
- Overcurrent protection: Built-in protection
Capacitive sensor, Metal thread, M30 x 1.5, DC PNP, Teach function, Electronic lock, Connector, Sensing range 8 mm [f]
Pneumatic cylinder with clean profile and stainless steel through piston rod
- Tough, metal housing
- Various teach-in methods via control panel or control cable
- Maximum detection reliability due to 3-color RGB LED technology
KTD 4-2 A4 art. 11058655
- Output signal: 4 - 20 mA
- SSI digital output
- Stainless steel housing
Frequency, Hz: 50/60
Current, A: 265
Voltage, V: 400
| Type | MP9-21005K KIT |
| Weight | 17.16 kg |