• ITV1000/2000/3000
  • Electro-Pneumatic Regulator

Cylinder type: 2-stage telescopic cylinder

USB converter unit with copy and backup function.

Pneumatic cylinder with stainless steel piston rod.

  • Stroke length: 125mm
  • Temperature: -20C … 80C
  • Pressure: 1,5…10bar

KFD2 CD2 EX1

  • Marking: space for marking on the front panel
  • Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013 (industrial premises)
  • Degree of protection: IEC 60529:2001
  • Protection against electric shock: UL 61010-1:2004
  • Ambient temperature: -20...60 °C (-4...140 °F)

KFD2 CD2 EX2

  • Maximum current consumption: 100 mA
  • Response time: < 250 ms
  • Overcurrent protection: Yes
  • Short circuit protection: Yes
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Level sensing input
  • Adjustable range 1 k Omega- ... 150 k Omega-
  • Relay contact output
  • Fault relay contact output
  • Adjustable time delay up to 10 s
  • Minimum/maximum control
  • Line fault detection (LFD)

KFD2 GU 1

  • Resolution: 0.1°C or 0.1°F
  • Overload: 150% of the measurement range within 2 seconds
  • Short Circuit: The output is protected against short circuits to power and ground
  • Input resistance: RTD: ≤ 20 ohms
  • Thermocouple: ≤ 2 MΩ
  • Output resistance: ≤ 2 ohms
  • 2-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Current output up to 700 Omega- load
  • HART I/P and valve positioner
  • Line fault detection (LFD)
  • Accuracy 0.05 %
  • Terminal blocks with test sockets
  • Up to SIL 2 acc. to IEC 61508
  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Usable as signal splitter (1 input and 2 outputs)
  • 2 x 2 relay contact outputs with AND logic
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc. to IEC 61508

KFD2 STC4 2

  • Connection: Screw terminals
  • Mounting: On a 35 mm DIN rail according to EN 60715: 2001
  • EC type conformity certificate: BAS 99 ATEX 7025 X
  • Certificate: TÜV 99 ATEX 1499 X
  • IECEx certificate: IECEx BAS 04.0015X IECEx CML 15.0055X
  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Input 2-wire SMART transmitters
  • Output 0/4 mA ... 20 mA current sink
  • Terminal blocks with test sockets
  • Up to SIL 2 acc. to IEC 61508

KFD2 STV4 EX2 2

  • Input Impedance: Approx. 200 ohms
  • Maximum input voltage: 30 V
  • Reverse polarity protection: Built-in protection
  • Overcurrent protection: Built-in protection


Capacitive sensor, Metal thread, M30 x 1.5, DC PNP, Teach function, Electronic lock, Connector, Sensing range 8 mm [f]

Pneumatic cylinder with clean profile and stainless steel through piston rod

  • Tough, metal housing
  • Various teach-in methods via control panel or control cable
  • Maximum detection reliability due to 3-color RGB LED technology

KTD 4-2 A4 art. 11058655

  • Output signal: 4 - 20 mA
  • SSI digital output
  • Stainless steel housing

Frequency, Hz: 50/60
Current, A: 265
Voltage, V: 400

TypeMP9-21005K KIT
Weight17.16 kg

LFL2 BK U PUR5

  • Rated voltage: 250 V AC / 150 V DC
  • Maximum current: 1 A DC / 3 A AC
  • Minimum switching current: 10 mA
  • Electrical strength: 2000 V AC
  • Degree of insulation resistance: > 100 MΩ
  • Voltage drop across contacts: < 1 V at nominal current
  • Switching time: < 10 ms

LFL2 CK U PUR3

  • Maximum switching power: 750 VA
  • Minimum switching current: 10 μA
  • Minimum switching power: 0.25 VA
  • Trigger time: < 10 ms
  • Trigger time: < 10 ms
  • Electrical strength: 2000 V AC
  • Insulation resistance: > 100 MΩ

LFL2 CK U PUR5

  • Process pressure (static pressure): ≤ 3 bar (43.5 psi) at 20°C (68°F)
  • Density: ≥ 0.8 g/cm³
  • Ambient temperature: 5 ... 70°C (41 ... 158°F)
  • Storage temperature: -25 ... 70°C (-13 ... 158°F)
  • Altitude: ≤ 2000 m above sea level
  • Degree of protection: IP68
  • Cable length: 5 m

LFL2 CK U PVC3

  • Maximum power: 25 VA
  • Minimum switching current: 10 mA
  • Minimum switching voltage: 1 V
  • Trigger time: ≤ 10 ms
  • Trigger time: ≤ 10 ms

LFL2 CK U PVC5

  • Degree of protection: IP65/IP67
  • Operating temperature range: From -20°C to +70°C
  • Installation: Vertical or horizontal
TypeLine filter
Weight180 kg

LK28 Z F1 31 116

  • Type: infrared LED
  • Wavelength: 870 nm
  • Rise/fall time: < 2 µs
  • Electronic level sensor,
  • DC PNP/NPN,
  • Gold-plated contacts,
  • Probe length: 11 mm,
  • Communication interface: IO-Link 1.1,
  • Connector, Gold-plated contacts, 2 switching outputs
  • Electronic level sensor,
  • DC PNP/NPN,
  • Gold-plated contacts,
  • Probe length: 11 mm,
  • Communication interface: IO-Link 1.1,
  • Connector, Gold-plated contacts, 2 switching outputs
  • circuit voltage 24...48 V DC
  • rated operational voltage 250 V AC 50/60 Hz
  • net weight: 0.22 kg