Pressure transducer
Pressure transducer
Digital pH electrode for measuring ORP
Measurement range

pH -2 to 14

Process temperature

0 to 140 В°C
(32 to 280 В°F)

Process pressure

0 to 7 bar abs
(0 to 101.5 psi)

Measuring cell

+100 mbar....+40 bar
(+1.5 psi....600 psi)

Measuring cell

+400 mbar....+400 bar
(+6 psi...+6000 psi)

Measuring cell

+400 mbar....+40 bar
(+6 psi....+600 psi)

Limit pressure switch
Limit pressure switch
Limit pressure switch
Measurement range

pH 1 - 12

Process temperature

0 - 80 C (32 - 176 F)

Process pressure

1 - 4 bar abs (15 - 60 psi)

art. 10127191

special typesensor for high temperatures
nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable4 ... 15 mm
output circuitPNP make function (NO)
operating temperature-40 ... +200 °C

art. 10164642

nominal sensing distance Sn0,5 mm
mounting typenon-flush
GND electrodeno
output circuitNPN make function (NO)
operating temperature0 ... +70 °C

art. 11039126

special typeliquid level sensor for wastewater
nominal sensing distance Sn0,1 mm
mounting typenon-flush
output circuitNPN make function (NO)
operating temperature0 ... +50 °C

art. 10129050

nominal sensing distance Sn0,5 mm
mounting typenon-flush
GND electrodeno
output circuitPNP make function (NO)
operating temperature0 ... +70 °C

art. 11017111

special typeliquid level sensor for wastewater
nominal sensing distance Sn0,1 mm
mounting typenon-flush
output circuitPNP make function (NO)
operating temperature0 ... +50 °C

art. 10164795

nominal sensing distance Sn0,5 mm
mounting typenon-flush
GND electrodeno
output circuitPNP break function (NC)
operating temperature0 ... +70 °C
nominal sensing distance Sn5 mm
mounting typenon-flush
GND electrodeno
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 11001668

nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable2 ... 15 mm
mounting typenon-flush
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 11001669

nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable2 ... 15 mm
mounting typenon-flush
output circuitNPN break function (NC)
operating temperature-25 ... +75 °C

art. 11001670

nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable2 ... 15 mm
mounting typenon-flush
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C
nominal sensing distance Sn5 mm
mounting typenon-flush
GND electrodeno
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C