measuring distance Sd | 50 ... 400 mm |
adjustment | IO-Link |
Teach-in range min. | > 20 mm |
operating temperature | 0 ... +50 °C |
GCA cable sensor
- Cable diameter: 0.8 mm
- Pulling force: ≤11 Н
- Retraction force: >3 Н
- Linearity: ±0.02 %
art. 11144078
- 0 ...3 mm
- voltage output
- cable, 2 m
- -25 ... 75 °C
- IP 67
measuring distance Sd | 16 ... 26 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 1 mm |
operating temperature | 0 ... +50 °C |
Distance sensorsOADM 12I6460/S35A with16 ... 120 mm,0 ... +50 °C,100 mA
measuring distance Sd | 16 ... 120 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 2 mm |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 16 ... 26 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 1 mm |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 50 ... 350 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 5 mm |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 50 ... 550 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 10 mm |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 50 ... 550 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 10 mm |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 50 ... 550 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 10 mm |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 100 ... 200 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 5 mm |
operating temperature | 0 ... +50 °C |
- output circuit: analog
- operating temperature: 0 ... +50 °C
- protection class: IP 67
art. 11164061
measuring distance Sd | 30 ... 130 mm |
adjustment | no |
wave length | 650 nm |
operating temperature | 0 ... +50 °C |
art. 10144598
measuring distance Sd | 30 ... 70 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 2 mm |
operating temperature | 0 ... +50 °C |
art. 10144599
measuring distance Sd | 30 ... 130 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 3 mm |
operating temperature | 0 ... +50 °C |
art. 10144601
measuring distance Sd | 100 ... 600 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 10 mm |
operating temperature | 0 ... +50 °C |
art. 10144602
measuring distance Sd | 200 ... 1000 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 20 mm |
operating temperature | 0 ... +50 °C |
art. 10144603
measuring distance Sd | 30 ... 70 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 2 mm |
operating temperature | 0 ... +50 °C |
art. 11012177
measuring distance Sd | 200 ... 1000 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 20 mm |
operating temperature | -20 ... +60 °C |
art. 11003837
measuring distance Sd | 200 ... 1000 mm |
adjustment | Teach-in: button / external |
Teach-in range min. | > 10 mm |
operating temperature | 0 ... +50 °C |
art. 11017788
measuring distance Sd | 50 ... 300 mm |
special type | Washdown design |
adjustment | external |
operating temperature | 0 ... +50 °C |
Voltage supply range | 26,5 - 33,1 VDC |
supply current | ≤ 200 mA |
temperature range | -25...+70 °C -25...+85 °C |
measuring distance Sd | 50 ... 400 mm |
special type | hygienic design |
adjustment | IO-Link |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 50 ... 400 mm |
special type | hygienic design |
adjustment | IO-Link |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 50 ... 400 mm |
special type | hygienic design |
adjustment | IO-Link |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 50 ... 400 mm |
adjustment | IO-Link |
Teach-in range min. | > 20 mm |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 50 ... 400 mm |
adjustment | IO-Link |
Teach-in range min. | > 20 mm |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 50 ... 400 mm |
adjustment | IO-Link |
Teach-in range min. | > 20 mm |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 50 ... 400 mm |
adjustment | IO-Link |
Teach-in range min. | > 20 mm |
operating temperature | 0 ... +50 °C |
Baumer distance sensors are devices that determine current distance to an object and its movement.
The German company produces the following types of distance sensors:
- Optical
- Ultrasonic
- Radar
- Inductive
- Encoders
- Accessories
Optical distance sensors use a light signal for their measurements. They are able to work at a distance of 13 m. Generally, a laser is used as a light source.
Ultrasonic distance sensors use ultrasonic signals for measurements. They operate at distance up to 6 m and have an accuracy up to 0.1mm. Such equipment are capable for operating in environments with a large presence of pollution.
Radar distance sensors are designed specifically for harsh environments. They have a miniature but very robust design. Such equipment operates at temperatures from -40 to 65 ° C (-40 / 150 ° F). They have IP68 / IP69K enclosure rating and more due to proTect + technology.
Inductive distance sensors are used to work with metal objects using inductive signals. They have a microcontroller in their design and operate on the AlphaProx platform.
Encoders family for distance measurement includes a series of linear magnetic, wire draw (rope) and measuring wheel models.
The company also produces accessories, such as reflectors, cables, peripherals, adapters and mounting tools.
The distance sensors by Baumer hubner includes various models with different operating principles, which combine precision and reliability even in extreme conditions.
More detailed information you can see here: