Baumer Distance sensors
art. 11233990
- Automatic adjustment of exposure time for precise measurements on changing materials
- High immunity to ambient light for reliable measurements regardless of ambient conditions
- Line beam shape for particularly robust measurement results on structured surfaces
- Adjustable filters for particularly stable measurement results
art. 11231079
- Automatic adjustment of exposure time for precise measurements on changing materials
- High immunity to ambient light for reliable measurements regardless of ambient conditions
- Line beam shape for particularly robust measurement results on structured surfaces
- Adjustable filters for particularly stable measurement results
art. 11232075
- Automatic adjustment of exposure time for precise measurements on changing materials
- High immunity to ambient light for reliable measurements regardless of ambient conditions
- Line beam shape for particularly robust measurement results on structured surfaces
- Adjustable filters for particularly stable measurement results
art. 11231343
- Automatic adjustment of exposure time for precise measurements on changing materials
- High immunity to ambient light for reliable measurements regardless of ambient conditions
- Line beam shape for particularly robust measurement results on structured surfaces
- Adjustable filters for particularly stable measurement results
art. 11232078
- Automatic adjustment of exposure time for precise measurements on changing materials
- High immunity to ambient light for reliable measurements regardless of ambient conditions
- Line beam shape for particularly robust measurement results on structured surfaces
- Adjustable filters for particularly stable measurement results
art. 11232072
- Automatic adjustment of exposure time for precise measurements on changing materials
- High immunity to ambient light for reliable measurements regardless of ambient conditions
- Point beam shape for a precise measurement
- Adjustable filters for particularly stable measurement results
art. 11231082
- Automatic adjustment of exposure time for precise measurements on changing materials
- High immunity to ambient light for reliable measurements regardless of ambient conditions
- Point beam shape for a precise measurement
- Adjustable filters for particularly stable measurement results
art. 11216521
- Adjustable reference distance (zero point position)
- Intuitive limitation of the measuring range
- Configurable switching output
- Selectable filters and trigger modes
- Additional data such as signal quality on request
- Export and import function for parameter sets
art. 11200058
- Touch display with Live Monitor function
- Configurable switching output
- Selectable filters and trigger modes
PP20H Baumer - Fully welded pressure sensor with hygienic connection
- All market typical hygienic connections available
- Resistant to all common CIP cleaning media
- Condensate-proof measuring cell
- Optionally available with IO-Link (in parallel to 4 ... 20 mA)
- Space-savng installations from DN 25 on
| Voltage supply range | 26,5 - 33,1 VDC |
| supply current | ≤ 200 mA |
| temperature range | -25...+70 °C -25...+85 °C |
| measuring distance Sd | 50 ... 400 mm |
| special type | hygienic design |
| adjustment | IO-Link |
| operating temperature | 0 ... +50 °C |
| measuring distance Sd | 50 ... 400 mm |
| special type | hygienic design |
| adjustment | IO-Link |
| operating temperature | 0 ... +50 °C |
| measuring distance Sd | 50 ... 400 mm |
| special type | hygienic design |
| adjustment | IO-Link |
| operating temperature | 0 ... +50 °C |
| measuring distance Sd | 50 ... 400 mm |
| adjustment | IO-Link |
| Teach-in range min. | > 20 mm |
| operating temperature | 0 ... +50 °C |
| measuring distance Sd | 50 ... 400 mm |
| adjustment | IO-Link |
| Teach-in range min. | > 20 mm |
| operating temperature | 0 ... +50 °C |
| measuring distance Sd | 50 ... 400 mm |
| adjustment | IO-Link |
| Teach-in range min. | > 20 mm |
| operating temperature | 0 ... +50 °C |
| measuring distance Sd | 50 ... 400 mm |
| adjustment | IO-Link |
| Teach-in range min. | > 20 mm |
| operating temperature | 0 ... +50 °C |
| measuring distance Sd | 50 ... 400 mm |
| adjustment | IO-Link |
| Teach-in range min. | > 20 mm |
| operating temperature | 0 ... +50 °C |
| measuring distance Sd | 50 ... 400 mm |
| special type | Washdown design |
| adjustment | IO-Link |
| operating temperature | 0 ... +50 °C |
| measuring distance Sd | 50 ... 400 mm |
| special type | Washdown design |
| adjustment | IO-Link |
| operating temperature | 0 ... +50 °C |
art. 11173270
- 0 ...2 mm
- voltage output
- cable PUR, 2 m
- 10 ... 60 °C
- IP 67
art. 11173193
- 0 ... 2 mm
- voltage output
- cable PVC, 2 m
- 10 ... 60 °C
- IP 67
art. 11173266
- 0 ... 2 mm
- voltage output
- flylead connector PVC M8, L=200 mm
- 10 ... 60 °C
- IP 67
art. 11214892
- Distance measuring
- 0 ... 3 mm
- PNP / push-pull
- IO-Link
- Cable PUR, 2m
- -20 ... 70 °C
- IP 67
art. 11193946
- distance measuring
- 0 ... 3 mm
- PNP / push-pull
- IO-Link
- connector M8
- -25 ... 75 °C
- IP 67
art. 11130472
- 0 ... 2 mm
- voltage output
- cable, 2 m
- -10 ... 70 °C
- IP 67
art. 11193947
- distance measuring
- 0 ... 3 mm
- PNP / push-pull
- IO-Link
- connector M8
- -25 ... 75 °C
- IP 67
art. 11175999
- 0 ... 3 mm
- voltage output
- Teach-in
- connector M8
- -25 ... 75 °C
- IP 67
art. 11141038
- 0 ... 3 mm
- voltage output
- connector M8
- -25 ... 75 °C
- IP 67