Baumer Sensors
Choose a subcategory:
Show all categories
art. 10134310
Magnetic angle sensors MDRM 18U9524 withvoltage output, IP 67,20 mA, -25 … 85 °C
art. 11050340
type | magneto-resistive |
assured sensing distance Sa | 60 mm |
output indicator | LED red |
output circuit | NPN make function (NO) |
operating temperature | -25 ... +75 °C |
art. 11050341
type | magneto-resistive |
assured sensing distance Sa | 60 mm |
output indicator | LED red |
output circuit | NPN break function (NC) |
operating temperature | -25 ... +75 °C |
art. 10133613
type | magneto-resistive |
assured sensing distance Sa | 60 mm |
output indicator | LED red |
output circuit | PNP make function (NO) |
operating temperature | -25 ... +75 °C |
art. 11003474
type | magneto-resistive |
assured sensing distance Sa | 60 mm |
output indicator | LED red |
output circuit | PNP make function (NO) |
operating temperature | -25 ... +75 °C |
art. 11050336
type | magneto-resistive |
version | full metal |
assured sensing distance Sa | 60 mm |
output circuit | NPN make function (NO) |
operating temperature | -25 ... +75 °C |
art. 11050334
type | magneto-resistive |
version | full metal |
assured sensing distance Sa | 60 mm |
output circuit | PNP make function (NO) |
operating temperature | -25 ... +75 °C |
type | magneto-resistive |
version | full metal |
assured sensing distance Sa | 60 mm |
output circuit | PNP break function (NC) |
operating temperature | -25 ... +75 °C |
art. 11033276
- Bore Diam. 4 mm
version | full metal |
sensor type | differential hall sensor |
gear material | ferromagnetic |
operating temperature | -40 ... +120 °C |
version | full metal |
sensor type | differential hall sensor |
working distance max. | 1,0 mm (module 1) |
operating temperature | -40 ... +120 °C |
version | full metal |
sensor type | differential hall sensor |
working distance max. | 2,5 mm (module 3) |
operating temperature | -40 ... +120 °C |
art. 10221367
- break function (NC) mechanical
- cable, 2 m
- -20 ... 75 °C
- IP 50
art. 10251051
repeat accuracy | < 0,001 mm |
activating force | 100 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10240394
repeat accuracy | < 0,001 mm |
activating force | 100 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10251048
repeat accuracy | < 0,001 mm |
activating force | 30 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10241610
repeat accuracy | < 0,001 mm |
activating force | 30 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10223784
- break function (NC) mechanical
- cable, 2 m
- -20 ... 75 °C
- IP 50
art. 10251049
repeat accuracy | < 0,001 mm |
activating force | 50 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10251050
repeat accuracy | < 0,001 mm |
activating force | 75 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10238652
repeat accuracy | < 0,001 mm |
activating force | 75 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10223758
- break function (NC) mechanical
- cable, 2 m
- -20 ... 75 °C
- IP 50
art. 10251047
repeat accuracy | < 0,001 mm |
activating force | 100 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10251044
repeat accuracy | < 0,001 mm |
activating force | 30 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10251105
repeat accuracy | < 0,001 mm |
activating force | 50 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10251046
repeat accuracy | < 0,001 mm |
activating force | 75 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10211160
repeat accuracy | < 0,001 mm |
activating force | 100 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10210530
repeat accuracy | < 0,001 mm |
activating force | 30 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10212637
repeat accuracy | < 0,001 mm |
activating force | 50 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
art. 10211484
repeat accuracy | < 0,001 mm |
activating force | 75 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |