Baumer Sensors

Choose a subcategory:
Show all categories

art. 10154484

emitter / receiverreceiver
scanning range sd0 ... 1000 mm
scanning range far limit Sde0 ... 1000 mm
output circuitPNP make function (NO)
operating temperature0 ... +60 °C

art. 10243461

emitter / receiverreceiver
scanning range sd0 ... 700 mm
scanning range far limit Sde0 ... 700 mm
output circuitPNP complementary
operating temperature0 ... +60 °C

art. 10156815

scanning range sd60 ... 400 mm
scanning range close limit Sdc60 ... 400 mm
scanning range far limit Sde60 ... 400 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10151966

scanning range sd20 ... 200 mm
scanning range close limit Sdc20 ... 200 mm
scanning range far limit Sde20 ... 200 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10158528

scanning range sd40 ... 400 mm
scanning range far limit Sde60 ... 400 mm
hysteresis typ.4 % Sde
output circuitNPN break function (NC)
operating temperature-10 ... +60 °C

art. 10156843

scanning range sd40 ... 400 mm
scanning range far limit Sde60 ... 400 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-10 ... +60 °C

art. 11053880

special typeHighspeed
scanning range sd10 ... 70 mm
scanning range far limit Sde30 ... 70 mm
output circuitPNP make function (NO) / break function (NC)
operating temperature-10 ... +60 °C

art. 11053882

special typeHighspeed
scanning range sd0 ... 40 mm
scanning range far limit Sde0 ... 40 mm
output circuitPNP make function (NO) / break function (NC)
operating temperature-10 ... +60 °C

art. 10156844

scanning range sd60 ... 400 mm
scanning range close limit Sdc60 ... 400 mm
scanning range far limit Sde60 ... 400 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10147642

scanning range sd20 ... 200 mm
scanning range close limit Sdc20 ... 200 mm
scanning range far limit Sde20 ... 200 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10151802

scanning range sd2 ... 82 mm
scanning range close limit Sdc2 ... 82 mm
scanning range far limit Sde2 ... 82 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10123679

scanning range sd100 ... 700 mm
scanning range far limit Sde110 ... 700 mm
hysteresis typ.4 % Sde
output circuitNPN break function (NC)
operating temperature-10 ... +60 °C

art. 10233682

scanning range sd100 ... 700 mm
scanning range far limit Sde110 ... 700 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-10 ... +60 °C
scanning range sd100 ... 700 mm
scanning range far limit Sde110 ... 700 mm
hysteresis typ.4 % Sde
output circuitPNP break function (NC)
operating temperature-10 ... +60 °C
scanning range sd100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-10 ... +60 °C
scanning range sd100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
hysteresis typ.4 % Sde
output circuitPNP break function (NC)
operating temperature-10 ... +60 °C

UNAM 30I6103 art. 10130385

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10130000

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10233667

scanning range sd200 ... 1500 mm
scanning range far limit Sde200 ... 1500 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-25 ... +60 °C

art. 10129076

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10119391

scanning range sd100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
versionstandard
output circuitvoltage output
operating temperature-10 ... +60 °C
scanning range sd350 ... 2500 mm
scanning range far limit Sde350 ... 2500 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-25 ... +60 °C

art. 10232793

scanning range sd350 ... 2500 mm
scanning range far limit Sde350 ... 2500 mm
hysteresis typ.4 % Sde
output circuitPNP break function (NC)
operating temperature-25 ... +60 °C

art. 11099364

scanning range sd600 ... 6000 mm
scanning range close limit Sdc600 ... 6000 mm
scanning range far limit Sde600 ... 6000 mm
output circuitcurrent output
operating temperature-25 ... +60 °C

art. 11099363

scanning range sd600 ... 6000 mm
scanning range close limit Sdc600 ... 6000 mm
scanning range far limit Sde600 ... 6000 mm
output circuitvoltage output
operating temperature-25 ... +60 °C

art. 11182608

  • 20 ... 200 mm
  • current output
  • external Teach-in
  • connector M12
  • 60 °C
  • IP 67

art. 11182657

  • 10 ... 200 mm
  • NPN make function (NO)
  • external Teach-in
  • connector M12
  • 60 °C
  • IP 67

art. 10158870

special typechemically resistant
scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
output circuitcurrent output
operating temperature0 ... +60 °C

art. 10161025

special typechemically resistant
scanning range sd100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitPNP make function (NO)
operating temperature0 ... +60 °C

art. 10160748

special typechemically resistant
scanning range sd60 ... 400 mm
scanning range close limit Sdc60 ... 400 mm
output circuitvoltage output
operating temperature0 ... +60 °C