art. 10150852

scanning range sd200 ... 2000 mm
scanning range close limit Sdc200 ... 2000 mm
scanning range far limit Sde200 ... 2000 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10129045

scanning range sd60 ... 400 mm
scanning range close limit Sdc60 ... 400 mm
scanning range far limit Sde60 ... 400 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10124954

scanning range sd30 ... 250 mm
scanning range far limit Sde30 ... 250 mm
hysteresis typ.4 % Sde
output circuitNPN make function (NO)
operating temperature-25 ... +60 °C

art. 10232775

scanning range sd60 ... 400 mm
scanning range far limit Sde60 ... 400 mm
hysteresis typ.4 % Sde
output circuitNPN break function (NC)
operating temperature-25 ... +60 °C
scanning range sd30 ... 250 mm
scanning range far limit Sde30 ... 250 mm
hysteresis typ.4 % Sde
output circuitNPN break function (NC)
operating temperature-25 ... +60 °C

art. 10233436

scanning range sd100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-10 ... +60 °C

art. 10232763

Ultrasonic proximity sensorsUNDK 30P1703/S14 with35 mA, 100 ... 1000 mm,-10 ... +60 °C, IP 67

art. 10232772

scanning range sd60 ... 400 mm
scanning range far limit Sde60 ... 400 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-25 ... +60 °C

art. 10118625

scanning range sd30 ... 250 mm
scanning range far limit Sde30 ... 250 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-25 ... +60 °C

art. 10118626

scanning range sd30 ... 250 mm
scanning range far limit Sde30 ... 250 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-25 ... +60 °C

art. 10232774

scanning range sd60 ... 400 mm
scanning range far limit Sde60 ... 400 mm
hysteresis typ.4 % Sde
output circuitPNP break function (NC)
operating temperature-25 ... +60 °C

art. 10124957

scanning range sd30 ... 250 mm
scanning range far limit Sde30 ... 250 mm
hysteresis typ.4 % Sde
output circuitPNP break function (NC)
operating temperature-25 ... +60 °C

art. 10127059

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10154252

scanning range sd200 ... 2000 mm
scanning range close limit Sdc200 ... 2000 mm
scanning range far limit Sde200 ... 2000 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10150851

scanning range sd200 ... 2000 mm
scanning range close limit Sdc200 ... 2000 mm
scanning range far limit Sde200 ... 2000 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10136785

scanning range sd60 ... 400 mm
scanning range close limit Sdc60 ... 400 mm
scanning range far limit Sde60 ... 400 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10130203

scanning range sd30 ... 250 mm
scanning range close limit Sdc30 ... 250 mm
scanning range far limit Sde30 ... 250 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10126903

scanning range sd30 ... 250 mm
scanning range close limit Sdc30 ... 250 mm
scanning range far limit Sde30 ... 250 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10118991

scanning range sd100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
repeat accuracy< 0,5 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10243473

scanning range sd100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
repeat accuracy< 0,5 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10233767

scanning range sd60 ... 400 mm
scanning range far limit Sde60 ... 400 mm
repeat accuracy< 0,5 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10119437

scanning range sd30 ... 250 mm
scanning range far limit Sde30 ... 250 mm
repeat accuracy< 0,5 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 11135775

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitcurrent output
operating temperature-25 ... +60 °C

art. 11119994

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitvoltage output
operating temperature-25 ... +70 °C

art. 11200640

  • 20 ... 1000 mm
  • current output
  • qTeach, line-Teach, IO-Link
  • connector M12 5 pin
  • -25 ... 65 °C
  • IP 69

art. 11200639

  • 20 ... 1000 mm
  • voltage output
  • qTeach, line-Teach, IO-Link
  • connector M12 5 pin
  • -25 ... 65 °C
  • IP 69

art. 11228073

  • receiver
  • 0... 2000 mm
  • push-pull
  • qTeach, line-Teach, IO-Link
  • connector M12 5 pin
  • -25 ... 65 °C
  • IP 69

art. 11120038

scanning range sd100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
hysteresis typ.4 % Sde
operating temperature-25 ... +70 °C

art. 11200644

  • 20 ... 1000 mm
  • push-pull
  • qTeach, line-Teach, IO-Link
  • connector M12 5 pin
  • -25 ... 65 °C
  • IP 69

art. 11200645

  • 20 ... 1000 mm
  • push-pull
  • qTeach, line-Teach, IO-Link
  • connector M12 5 pin
  • -25 ... 65 °C
  • IP 69