Baumer Ultrasonic Sensors
scanning range sd | 100 ... 1000 mm |
scanning range close limit Sdc | 100 ... 1000 mm |
scanning range far limit Sde | 100 ... 1000 mm |
output circuit | current output |
operating temperature | -10 ... +60 °C |
art. 10130000
scanning range sd | 100 ... 1000 mm |
scanning range close limit Sdc | 100 ... 1000 mm |
scanning range far limit Sde | 100 ... 1000 mm |
output circuit | current output |
operating temperature | -10 ... +60 °C |
art. 10233667
scanning range sd | 200 ... 1500 mm |
scanning range far limit Sde | 200 ... 1500 mm |
hysteresis typ. | 4 % Sde |
output circuit | PNP make function (NO) |
operating temperature | -25 ... +60 °C |
art. 10129076
scanning range sd | 100 ... 1000 mm |
scanning range close limit Sdc | 100 ... 1000 mm |
scanning range far limit Sde | 100 ... 1000 mm |
output circuit | voltage output |
operating temperature | -10 ... +60 °C |
art. 10119391
scanning range sd | 100 ... 1000 mm |
scanning range far limit Sde | 100 ... 1000 mm |
version | standard |
output circuit | voltage output |
operating temperature | -10 ... +60 °C |
scanning range sd | 350 ... 2500 mm |
scanning range far limit Sde | 350 ... 2500 mm |
hysteresis typ. | 4 % Sde |
output circuit | PNP make function (NO) |
operating temperature | -25 ... +60 °C |
art. 10232793
scanning range sd | 350 ... 2500 mm |
scanning range far limit Sde | 350 ... 2500 mm |
hysteresis typ. | 4 % Sde |
output circuit | PNP break function (NC) |
operating temperature | -25 ... +60 °C |
art. 11099364
scanning range sd | 600 ... 6000 mm |
scanning range close limit Sdc | 600 ... 6000 mm |
scanning range far limit Sde | 600 ... 6000 mm |
output circuit | current output |
operating temperature | -25 ... +60 °C |
art. 11099363
scanning range sd | 600 ... 6000 mm |
scanning range close limit Sdc | 600 ... 6000 mm |
scanning range far limit Sde | 600 ... 6000 mm |
output circuit | voltage output |
operating temperature | -25 ... +60 °C |
art. 11182657
- 10 ... 200 mm
- NPN make function (NO)
- external Teach-in
- connector M12
- 60 °C
- IP 67
art. 10158870
special type | chemically resistant |
scanning range sd | 100 ... 1000 mm |
scanning range close limit Sdc | 100 ... 1000 mm |
output circuit | current output |
operating temperature | 0 ... +60 °C |
art. 10161025
special type | chemically resistant |
scanning range sd | 100 ... 1000 mm |
scanning range far limit Sde | 100 ... 1000 mm |
output circuit | PNP make function (NO) |
operating temperature | 0 ... +60 °C |
art. 10160748
special type | chemically resistant |
scanning range sd | 60 ... 400 mm |
scanning range close limit Sdc | 60 ... 400 mm |
output circuit | voltage output |
operating temperature | 0 ... +60 °C |
art. 11007885
scanning range sd | 3 ... 150 mm |
scanning range far limit Sde | 3 ... 150 mm |
hysteresis typ. | 4 % Sde |
operating temperature | 0 ... +60 °C |
art. 11004100
scanning range sd | 3 ... 150 mm |
scanning range close limit Sdc | 3 ... 150 mm |
scanning range far limit Sde | 3 ... 150 mm |
operating temperature | 0 ... +60 °C |
scanning range sd | 30 ... 200 mm |
scanning range close limit Sdc | 30 ... 200 mm |
scanning range far limit Sde | 30 ... 200 mm |
output circuit | voltage output |
operating temperature | 0 ... +60 °C |
art. 11004067
scanning range sd | 3 ... 150 mm |
scanning range close limit Sdc | 3 ... 150 mm |
scanning range far limit Sde | 3 ... 150 mm |
output circuit | voltage output |
operating temperature | 0 ... +60 °C |
scanning range sd | 3 ... 150 mm |
scanning range close limit Sdc | 3 ... 150 mm |
scanning range far limit Sde | 3 ... 150 mm |
output circuit | voltage output |
operating temperature | 0 ... +60 °C |
art. 11007886
scanning range sd | 3 ... 150 mm |
scanning range far limit Sde | 3 ... 150 mm |
hysteresis typ. | 4 % Sde |
operating temperature | 0 ... +60 °C |
art. 11013770
scanning range sd | 30 ... 200 mm |
scanning range close limit Sdc | 30 ... 200 mm |
scanning range far limit Sde | 30 ... 200 mm |
output circuit | push-pull / IO-Link |
operating temperature | 0 ... +60 °C |
art. 11007903
scanning range sd | 3 ... 150 mm |
scanning range close limit Sdc | 3 ... 150 mm |
scanning range far limit Sde | 3 ... 150 mm |
operating temperature | 0 ... +60 °C |
art. 11007901
scanning range sd | 3 ... 150 mm |
scanning range close limit Sdc | 3 ... 150 mm |
scanning range far limit Sde | 3 ... 150 mm |
output circuit | voltage output |
operating temperature | 0 ... +60 °C |
art. 11007902
scanning range sd | 3 ... 150 mm |
scanning range close limit Sdc | 3 ... 150 mm |
scanning range far limit Sde | 3 ... 150 mm |
output circuit | voltage output |
operating temperature | 0 ... +60 °C |
art. 10161455
scanning range sd | 10 ... 200 mm |
scanning range far limit Sde | 30 ... 200 mm |
hysteresis typ. | 4 % Sde |
output circuit | NPN make function (NO) / break function (NC) |
operating temperature | -10 ... +60 °C |
art. 10161446
scanning range sd | 10 ... 200 mm |
scanning range far limit Sde | 30 ... 200 mm |
hysteresis typ. | 4 % Sde |
output circuit | NPN make function (NO) / break function (NC) |
operating temperature | -10 ... +60 °C |
art. 10161451
scanning range sd | 10 ... 200 mm |
scanning range far limit Sde | 30 ... 200 mm |
hysteresis typ. | 4 % Sde |
output circuit | PNP make function (NO) / break function (NC) |
operating temperature | -10 ... +60 °C |
art. 10161452
scanning range sd | 10 ... 200 mm |
scanning range far limit Sde | 30 ... 200 mm |
hysteresis typ. | 4 % Sde |
output circuit | PNP make function (NO) / break function (NC) |
operating temperature | -10 ... +60 °C |
art. 10159081
Ultrasonic sensors UNDK 10P8914/S35A with10 ... 200 mm,-10 ... +60 °C,380 kHz,IP 67
art. 10161449
scanning range sd | 20 ... 200 mm |
scanning range close limit Sdc | 20 ... 200 mm |
scanning range far limit Sde | 20 ... 200 mm |
output circuit | voltage output |
operating temperature | -10 ... +60 °C |
art. 10161450
scanning range sd | 20 ... 200 mm |
scanning range close limit Sdc | 20 ... 200 mm |
scanning range far limit Sde | 20 ... 200 mm |
output circuit | voltage output |
operating temperature | -10 ... +60 °C |