Radar distance measuring sensorsRR30 with 0,3 … 8,5 m,433 MHz, 12 … 30 VDC

art. 11220109

  • Small blind range 0.2 m
  • Push-pull and IO-Link outputs
  • Wide beam 12° opening angle
  • Suitable for structured surfaces (e.g. stones)
  • Ideal for level measurements in closed containers

art. 11221309

  • Universal measurement range 0.3 m to 12 m (18 m IO-Link)
  • Push-pull and IO-Link output
  • Narrow beam 6° opening angle
  • Suitable for distance measurement of all kinds
  • Ideal for level measurement in large containers

art. 11221333

  • Universal measurement range 0.3 m to 12 m (18 m IO-Link)
  • IO-Link and analog output (current 4...20 mA)
  • Narrow beam 6° opening angle
  • Suitable for distance measurement of all kinds
  • Ideal for level measurement in large containers

art. 11221320

  • Large measurement range up to 80 m via IO-Link
  • Push-pull and IO-Link output
  • Narrow beam reduces false object detection
  • Suitable for distance measurement in outdoor areas
  • Ideal for measurements on corner cube

art. 11221321

  • Large measurement range up to 80 m via IO-Link
  • IO-Link and analog output (current 4...20 mA)
  • Narrow beam reduces false object detection
  • Suitable for distance measurement in outdoor areas
  • Ideal for measurements on corner cube
Number of pole pairs1 = 2 poles
Transformation ratio0.5 ±5 %
Phase shift0° ±10°
Operating temperature-20...+100 °C
Number of pole pairs1 = 2 poles
Transformation ratio0.5 ±5 %
Phase shift0° ±10°
Operating temperature-40...+100 °C
Number of pole pairs1 = 2 poles
Transformation ratio0.5 ±5 %
Phase shift0° ±10°
Operating temperature-40...+100 °C

art. 11075442

  • confectioned connection cable M12/12-pin with power supply 24V/1.0A
  • Ethernet cable
  • 90° angled fixation bracket incl. screws
  • screw driver
  • Application Suite (Windows) via Download
  • VeriSens not included
Reversal tolerance≤0.1 %
Linearity tolerance≤0.15 %
Temperature coefficient±0.05 %/K (open-circuit)
Operating temperature-30...+130 °C
Reversal tolerance≤0.1 %
Linearity tolerance≤0.15 %
Temperature coefficient±0.05 %/K (open-circuit)
Operating temperature-30...+130 °C
Reversal tolerance≤0.1 %
Linearity tolerance≤0.15 %
Temperature coefficient±0.05 %/K (open-circuit)
Operating temperature-30...+130 °C
Reversal tolerance≤0.1 %
Linearity tolerance≤0.15 %
Temperature coefficient±0.05 %/K (open-circuit)
Operating temperature-30...+130 °C
Interference immunityEN 61000-6-2
Emitted interferenceEN 61000-6-3
Switching accuracy±4 % (Δn = 2 rpm/s);
= +20 % (Δn = 1500 rpm/s)
Operating temperature-30...+130 °C
Reversal tolerance≤0.1 %
Linearity tolerance≤0.15 %
Temperature coefficient±0.06 %/K (open-circuit)
Price on Request
One click request
Voltage supply5 VDC ±5 %
8...26 VDC
Reverse polarity protectionYes
Consumption w/o load≤85 mA
Operating temperature-20...+70 °C
Voltage supply5 VDC ±5 %
8...26 VDC
Reverse polarity protectionYes
Consumption w/o load≤85 mA
Operating temperature-20...+85 °C

art. 11185374

  • hard anodized lens protection with M62 thread
  • optional tube extension with Tube Module 6mm (11185376), Tube Module 12 mm (11185375) or Tube Module 36 mm (11198906). Use of several Tube Modules possible.
  • thread: M62
  • length 58 mm

art. 11185375

  • modular extension of the lens protection
  • thread: M62
  • length 12 mm

art. 11219506

  • Fastest limit value detection due to extremely short response times
  • Flexible parameterization and additional diagnostic data thanks to IO-Link
  • Shortest blind zone in its class
  • High performance in compact housing

art. 11219508

  • Most reliable object detection through barrier principle
  • Flexible parameterization and additional diagnostic data thanks to IO-Link
  • High performance in compact housing

art. 11219514

  • Most reliable object detection through barrier principle
  • Acquisition of two independent limit values
  • Detection of double sheets
  • High performance in compact housing

art. 11127346

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitvoltage - / current output
operating temperature-25 ... +65 °C (+60 °C current mode)

art. 11110575

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitvoltage - / current output
operating temperature-25 ... +65 °C (+60 °C current mode)

art. 11135756

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitcurrent output
operating temperature-25 ... +60 °C

art. 11126857

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitvoltage output
operating temperature-25 ... +65 °C

art. 11200625

  • 20 ... 1000 mm
  • current output
  • qTeach, line-Teach, IO-Link
  • connector M12 5 pin
  • -25 ... 65 °C
  • IP 67

art. 11200629

  • 20 ... 1000 mm
  • voltage output
  • qTeach, line-Teach
  • connector M12 5 pin
  • -25 ... 65 °C
  • IP 67

art. 11228075

  • receiver
  • 0... 2000 mm
  • push-pull
  • qTeach, line-Teach, IO-Link
  • connector M12 5 pin
  • -25 ... 65 °C