Endress+Hauser Other

Input

NAMUR
blocking: < 1,2 mA
conducting: > 2,1 mA

Output

relay contact

Power Supply

24 V DC

Secondary signal converter

Input

2 x universal (current, voltage, R, RTD, TC, resistance)

Output

2 x Analog (current, voltage)

Output

2 x Analog (current, voltage)

Display

LCD
7 segment
Multicolour
Bargraph
TAG unit
Colour change in case of failure

Power Supply

Not defined

Universal Energy manager and flow calculator

Calculations

mass/heat quantity
heat quantity difference
for gases: standard volume, heating value, mass

Application manager

Input

2...6x RTD
2...8x I
2...8x PFM
2...8x Impulse (aktive)
2...8x Impulse (passive)

Output

3...9x transmitter power supply

Display

Dot-Matrix LCD, backlit, colour change in case of alarm event

Calculations

heat quantity
heat quantity difference

Input

0/4...20 mA / HART
feeding/not feeding

Output

0/4...20 mA / HART
active/passive

Power Supply

24 V DC

Input

0/4...20 mA / HART
feeding/not feeding

Output

0/4...20 mA / HART
active/passive

Power Supply

20...250 V AC/DC

Output

24 VDC, 1,5 A

Power Supply

100...240 V AC (wide range power supply)
45...65 Hz

Output

24...28 V DC

Power Supply

100...240 V AC/DC

Input

24 V DC

Output

Uin - 0,8 V

Power Supply

24 V DC

Input

0/4...20 mA / HART
passive

Output

0/4...20 mA / HART
active

Power Supply

24 V DC

Input

1 x analog (U, I)

Output

1 x transmitter power supply

Output

1 x transmitter power supply

Display

LCD 6 mm (0.24")
4-digit
Bargraph

Power Supply

Not defined

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Source container for radioisotope complex

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Source container for radioisotope complex

Process temperature

max. 400В°C (752В°F)
(diptube)

Process pressure absolute / max. overpressure limit

Any (diptube)

Main wetted parts

Non- contact

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Main wetted parts

Non-contact

Cloud-based inventory management platform for transparent information within the supply chain.

Adapter with built-in power module

Output

WirelessHART communication interface
Transmission rate: Nominal 250 kBits/s
Operating frequency: 2.4 GHz (ISM band)
Transmission range under reference conditions:
Outdoor 250 m, indoor 50 m

Display

Integral via 3 LEDs

WirelessHART Gateway

Output

Ethernet (10 BASE-T/10 BASE TX)
- Configurable for HART IP and MODBUS TCP communication
RS-485 serial interface
- Configurable for HART Version 7.0 or MODBUS RTU communication
EtherNet/IP interface

Display

Integral via 5 LEDs

High-performing flowmeter with intelligent and dynamic adaptation to changing process conditions. Measurement of gases and gas mixtures in small line sizes.