Endress+Hauser Thermometers

Comfortable temperature measurement solution 100% compliance, 0% effort.
Automated temperature measurement solution - 100% compliance, 0% effort.
Response time

t50 = 2.5 s
t90 = 5.4 s

Max. process pressure (static)

at 20 В°C: 40 bar (580 psi)

Operating temperature range

Pt 100:
-40 В°C to 160 В°C
(-40 В°F to 320 В°F)

Max. immersion length on request

up to 900.00 mm (35.4'')

Response time

t50 = 2,5 s
t90 =9,5s

Max. process pressure (static)

at 20 В°C: 40 bar (580 psi)

Operating temperature range

PT 100:
-40 В°C ...160 В°C
(-40 В°F ...320 В°F)

Max. immersion length on request

up to 28'' (711 mm)
others on request

Max. process pressure (static)

40 bar (580 psi)

Maximum standard immersion length

4.000 mm (157,48")

Max. immersion length on request

Not defined

Max. process pressure (static)

40 bar (580 psi)

Maximum standard immersion length

48" (1.219 mm)

Accuracy

RTD Class A acc. to IEC 60751
TC class 1 acc. To EN 60584

Response time

depending on configuration

Max. process pressure (static)

depending on Thermowell

Operating temperature range

PT100: -50...500В°C
TC up to 1100В°C

Max. immersion length on request

Not defined

Accuracy

RTD Class A acc. to IEC 60751
TC class 1 acc. To EN 60584

Response time

depending on configuration

Max. process pressure (static)

depending on configuration

Operating temperature range

PT100: -50...500В°C
TC up to 600В°C

Max. immersion length on request

Not defined

Maximum standard immersion length

445 mm, other lenghts on request

Resistance thermometer

Resistance thermometer

Resistance thermometer

Resistance thermometer

Resistance thermometer
Temperature sensor

Multi-zone temperature sensor

Accuracy

+/- 0.1 В°C

Max. process pressure (static)

0 bar...0.5 bar
(0 psi...7.25 psi)

Multi-zone temperature sensor

Accuracy

+/- 0.1 В°C

Max. process pressure (static)

0 bar...0.5 bar
(0 psi...7.25 psi)

Accuracy

+/- 0.032 В°C (+/- 0.058 В°F)

Operating temperature range

Options:
-40 В°C...+75 В°C
(-40 В°F...+167 В°F)
-55 В°C...+235 В°C
(-67 В°F...+455 В°F)
-196 В°C...+100 В°C
(-321 В°F...+212 В°F)

Max. immersion length on request

up to 100 m (328 ft)

Accuracy

class A acc. to IEC 60751
class B acc. to IEC 60751

Response time

depending on configuration
63% rt = 20 s

Max. process pressure (static)

at 20 В°C: 100 bar (1.450 psi)
depends on configuration

Operating temperature range

PT100 WW:
-200 В°C ... 600 В°C
(-328 В°F ... 1.112 В°F)
PT100 TF:
-50 В°C ... 200 В°C
(-58 В°F ... 392 В°F)

Max. immersion length on request

up to 22.5" (571 mm)
others on request

Accuracy

class A acc. to IEC 60751
class B acc. to IEC 60751

Response time

depending on configuration
63% rt = 20 s

Max. process pressure (static)

at 20 В°C: 500 bar (7.252 psi)
depends on configuration

Operating temperature range

PT100 WW:
-200 В°C ... 600 В°C
(-328 В°F ... 1.112 В°F)
PT100 TF:
-50 В°C ... 200 В°C
(-58 В°F ... 392 В°F)

Max. immersion length on request

up to 22.5" (571 mm)
others on request

Accuracy

class A acc. to IEC 60751
class B acc. to IEC 60751

Response time

63% rt = 3 s

Max. process pressure (static)

Not applicable

Operating temperature range

PT100 WW:
-200 В°C ... 600 В°C
(-328 В°F ... 1.112 В°F)
PT100 TF:
-50 В°C ... 200 В°C
(-58 В°F ... 392 В°F)

Max. immersion length on request

up to 100" (2540 mm)
others on request

Accuracy

Standard acc. to ASTM E-230
Special acc. to ASTM E-230

Response time

depending on configuration
63% rt = 15,0 s

Max. process pressure (static)

Standard acc. to ASTM E-230
Special acc. to ASTM E-230

Operating temperature range

Type T:
-270 В°C ...370 В°C
(-454 В°F ...698 В°F)
Type J:
-210 В°C ...720 В°C
(-346 В°F ...1.328 В°F)
Type E:
-270 В°C ...820 В°C
(-454 В°F ...1.508 В°F)
Type K:
-270 В°C ...1.150 В°C
(-454 В°F ...2.102 В°F)
Type N:
-270 В°C ...1.150 В°C
(-454 В°F ...2.102 В°F)

Max. immersion length on request

up to 22.5" (571 mm)
others on request

Accuracy

Standard acc. to ASTM E-230
Special acc. to ASTM E-230

Response time

depending on configuration
63% rt = 15 s

Max. process pressure (static)

at 20В°C : 500bar (7.252 psi)
depends on configuration

Operating temperature range

Type T:
-270 В°C ...370 В°C
(-454 В°F ...698 В°F)
Type J:
-210 В°C ...720 В°C
(-346 В°F ...1.328 В°F)
Type E:
-270 В°C ...820 В°C
(-454 В°F ...1.508 В°F)
Type K:
-270 В°C ... 1.150 В°C
(-454 В°F ...2.102 В°F)
Type N:
-270 В°C ... 1.150 В°C
(-454 В°F ...2.102 В°F)

Max. immersion length on request

up to 22.5" (571 mm)
others on request

Accuracy

Standard acc. to ASTM E-230
Special acc. to ASTM E-230

Response time

63% rt = 1 s

Max. process pressure (static)

not applicable

Operating temperature range

Type T:
-270 В°C ...370 В°C
(-454 В°F ...698 В°F)
Type J:
-210 В°C ...720 В°C
(-346 В°F ...1.328 В°F)
Type E:
-270 В°C ...820 В°C
(-454 В°F ...1.508 В°F)
Type K:
-270 В°C ...1.150 В°C
(-454 В°F ...2.102 В°F)
Type N:
-270 В°C ...1.150 В°C
(-454 В°F ...2.102 В°F)

Max. immersion length on request

up to 100" (2540 mm)
others on request

Thermogilza

Max. process pressure (static)

50 bar (725 psi)

Maximum standard immersion length

4.000 mm (157,48")

Max. immersion length on request

10.000 mm (393,7")

Protective tube thermowell

Max. process pressure (static)

100 bar (1450 psi)

Maximum standard immersion length

5.000 mm (196,85")

Max. immersion length on request

10.000 mm (393,7")

Protective tube thermowell

Max. process pressure (static)

150 bar (2176 psi)

Maximum standard immersion length

4.000 mm (157,48")