Endress+Hauser Thermometers
Tesistance thermometer
Accuracyclass A acc. to IEC 60751
class AA acc. to IEC 60751
depending on configuration
Max. process pressure (static)depending on Thermowell
Operating temperature rangePT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)
up to 30.000,00 mm (1.181,10'')
Compact thermocouple
Accuracyclass 2 acc. to IEC 60584
Response timet50 = 1 s
t90 = 2 s
at 20 В°C: 25 bar (363 psi)
Operating temperature rangeType K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)
up to 100.000,00 mm (3.937,01'')
Temperature measuring device, compact. 3-A standard, surface finish: Ra min. 32 micro inch (150 grit). Transmitter: loop powered 4-20mA. Pt100, class A sensor.
Easytemp TSM470G,RTD-Transm.U.S Style Temperature measuring device, compact. Transmitter: loop powered 4-20mA. Pt100, class A sensor. M12 quick connector.
Easytemp TSM470P,RTD-Transm.U.S.Style Temperature measuring device, compact. 3-A standard, surface finish: Ra min. 20 micro inch (240 grit).
TST310 PT100
Response time: t50 = 3 s; t90 = 6 s
Max. process pressure (static): at 20 В°C: 25 bar (363 psi)
Max. immersion length on request: up to 10.000,00 mm (393,70'')
class A acc. to IEC 60751
class B acc. to IEC 60751
at 20 В°C: 1 bar (15 psi)
Operating temperature rangePT 100:
-30 В°C ...100 В°C
(-22 В°F ...212 В°F)
class A acc. to IEC 60751
class B acc. to IEC 60751
depending on configuration
Max. process pressure (static)at 20 В°C: 500 bar (7.252 psi)
Operating temperature rangePT 100:
-20 В°C ...180 В°C
(-4 В°F ...356 В°F)
up to 10.000,00 mm (393,70'')
+/- 0.05 K (refering to delta-T)
Response timedepending on configuration
t50 = 10 s
t90 = 31 s
at 20 В°C: 50 bar (725 psi)
Operating temperature rangePT 100:
-50 В°C ...200 В°C
(-58 В°F ...392 В°F)
up to 4.000,00 mm (157,48'')
depending on process connection up to 2500 lbs
Maximum standard immersion length500 mm (19,69")
Max. immersion length on request500 mm (19,69")
500 bar (7252 psi)
Maximum standard immersion length24"
500 bar (7252 psi)
Maximum standard immersion length24"
500 bar (7252 psi)
Maximum standard immersion length24"
Max. immersion length on requestNot defined
500 bar (7252 psi)
Maximum standard immersion length24"
Protective tube thermowell
Max. process pressure (static)50 bar (725 psi)
Maximum standard immersion length4.000 mm (157,48")
Max. immersion length on request10.000 mm (393,7")
Protective tube thermowell
Max. process pressure (static)50 bar (725 psi)
Maximum standard immersion length4.000 mm (157,48")
Max. immersion length on request10.000 mm (393,7")
Protective tube thermowell
Max. process pressure (static)50 bar (725 psi)
Maximum standard immersion length4.000 mm (157,48")
Max. immersion length on request10.000 mm (393,7")
Protective tube thermowell
Max. process pressure (static)50 bar (725 psi)
Maximum standard immersion length4.000 mm (157,48")
Max. immersion length on request10.000 mm (393,7")
Solid-machined thermowell
Max. process pressure (static)400 bar (5802 psi)
Maximum standard immersion length250 mm (9,84")
Max. immersion length on request400 mm (15,75")
Protective tube thermowell
Max. process pressure (static)50 bar (725 psi)
Maximum standard immersion length4.000 mm (157,48")
Max. immersion length on request10.000 mm (393,7")
Protective tube thermowell