Endress+Hauser

Choose a subcategory:
Show all categories

Ultrasonic measurement Time-of-Flight

Process temperature

-40 В°C ... 80 В°C
(-40 В°F ... 176 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Max. measurement distance

5 m (16ft)

Accuracy

+/- 2mm + 0.17% of measured distance

Main wetted parts

PVDF (fully welded IP68 / NEMA 6P)

Ultrasonic Level Gauge

Ultrasonic Level Gauge

Process temperature

-40 В°C ... 105 В°C
(-40 В°F ... 221 В°F)
30 min: 135 В°C / 275 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Max. measurement distance

5 m (16 ft)

Accuracy

+/- 2mm + 0.17% of measured distance

Main wetted parts

316L (fully welded IP68 / NEMA 6P)

Ultrasonic Level Gauge

Process temperature

-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Max. measurement distance

10 m (33 ft)

Accuracy

+/- 2mm + 0.17% of measured distance

Main wetted parts

PVDF (fully welded IP68 / NEMA 6P)

Ultrasonic sensor for level and flow measurement

Process temperature

-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 3 bar abs
(10 psi ... 43 psi)

Max. measurement distance

Max. measurement distance

Accuracy

+/- 2 mm + 0.17% of measured distance

Main wetted parts

UP (unsaturated polyester)
Silicon / Al PTFE coated

Ultrasonic Level Gauge

Process temperature

-40 В°C ... 80 В°C
or 150 В°C
(-40 В°F ... 176 В°F
or 302 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar...1.5 bar abs
(10 psi...22 psi)

Max. measurement distance

45 m (148 ft)

Accuracy

+/- 2mm + 0.17% of measured distance

Main wetted parts

UP (unsaturated polyester)
Silicon / PE foam (80В°C / 176В°F)
Silicon / stainless steal (150В°C / 302В°F))

Max. measurement error

MID 004 accuracy class II (2%)

Measuring range

0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min)

Medium temperature range

0 to 150В° (17.8 to 302 В°F)

Max. process pressure

PN 25/ ASME Cl. 150

Wetted materials

Measuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105

Ultrasonic flow meter

Accuracy

+/- 3 mm or +/- 0,2 % of set measuring range

Process temperature

-20 В°C ... 60 В°C
(- 4В°F ... 140 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 3 bar abs
(10 psi ... 44 psi)

Max. measurement distance

Max. measurement distance

Main wetted parts

PP/EPDM

Ultrasonic Level Gauge

Accuracy

+/- 2 mm or +/- 0.2 % of set measuring range

Process temperature

-40 В°C...+80 В°C
(-40 В°F...+176 В°F)

Process pressure / max. overpressure limit

0.7 bar...3 bar abs
(10 psi...44 psi)

Max. measurement distance

Liquids: 5 m (16 ft),
Solids: 2 m (6.6 ft)

Main wetted parts

PVDF

Ultrasonic Level Gauge

Accuracy

+/- 2 mm or +/- 0,2 % of set measuring range

Process temperature

-40 В°C ... 80 В°C
(-40 В°F ... 176 В°F)

Process pressure / max. overpressure limit

0.7 bar ... 3 bar abs
(10 psi ... 44 psi)

Max. measurement distance

Liquids: 8 m (26 ft),
Solids: 3.5 m (11 ft)

Main wetted parts

PVDF

Ultrasonic Level Gauge

Accuracy

+/- 4 mm or +/- 0,2 % of set measuring range

Process temperature

-40 В°C ... 80 В°C
(-40 В°F ... 176 В°F)

Process pressure / max. overpressure limit

0.7 bar ... 2.5 bar abs
(10 psi ... 36 psi)

Max. measurement distance

Liquids: 10 m (33 ft),
Solids: 5 m (16 ft)

Main wetted parts

PVDF

Ultrasonic Level Gauge

Accuracy

+/- 4mm or +/- 0,2 % of set measuring range

Process temperature

-40 В°C ... 80 В°C
(-40 В°F ... 176 В°F)

Process pressure / max. overpressure limit

0,7 bar ... 2,5 bar abs
(10 psi ... 36 psi)

Max. measurement distance

Liquids: 20 m (66 ft),
Solids: 10 m (33 ft)

Main wetted parts

PVDF

Ultrasonic Level Gauge

Accuracy

+/- 2mm + 0.17% of measured distance

Ultrasonic Level Gauge

Accuracy

+/- 2mm + 0.17% of measured distance

Ultrasonic Level Gauge

Ultrasonic Level Gauge

Multi-zone temperature sensor

Accuracy

+/- 0.1 В°C

Max. process pressure (static)

0 bar...0.5 bar
(0 psi...7.25 psi)

Multi-zone temperature sensor

Accuracy

+/- 0.1 В°C

Max. process pressure (static)

0 bar...0.5 bar
(0 psi...7.25 psi)

Accuracy

+/- 0.032 В°C (+/- 0.058 В°F)

Operating temperature range

Options:
-40 В°C...+75 В°C
(-40 В°F...+167 В°F)
-55 В°C...+235 В°C
(-67 В°F...+455 В°F)
-196 В°C...+100 В°C
(-321 В°F...+212 В°F)

Max. immersion length on request

up to 100 m (328 ft)

Vortex flowmeter
Vortex flowmeter
Vortex flowmeter
Vortex flowmeter

Compact pH electrode

Measurement range

pH 1-13 (<100ВµS/cm)

Process temperature

2В°C - 75В°C
(36В°F - 167В°F)

Process pressure

max. 3 bar
(43.5 psi)

Source container for radioisotope complex

Source container for radioisotope complex

Measures continuously all parameters relevant for the fermentation process. For transparency in fermentation processes, for example in beer..

Input

1 x analogue (I) / pulse (for flow)
1 x RTD (for temperature)
1 x analogue (I) (for density)
Loop power supply 24V DC (+/-16%)

Output

1 x analogue (I) / pulse (active)
2 x open collector

Display

160 x 80 Dot-Matrix LCD with white backlit
Colour change in case of alarm event
Active display area 70 x 34 mm

Calculations

Volume calculation

Sampling probe compatibility

Raman Rxn-10 probe

Wetted materials

Body: 316L stainless steel
Window: Proprietary material, optimized for bioprocesses
Process connection: PG13.5
Surface finish: Ra 15 with Electropolish to ASME BPE SF4 finish
Adhesive: USP Class VI and ISO 10993 compatible

Sterilization method

Autoclave