IFM

Choose a subcategory:
Show all categories
Mounting on DIN rail and panel, FC-E coupling module with external power supply, with addressing plug, Quick mounting technology for AS-i flat cable, AS-i interface to module upper part
Mounting on DIN rail and panel, FC coupling module, stainless steel, Quick mounting technology for AS-i flat cable, AS-i interface to module upper part
Mounting on DIN rail and panel, FC-E coupling module with external power supply, stainless steel, Quick mounting technology for AS-i flat cable, AS-i interface to module upper part
Module lower part M20, Mounting on DIN rail and panel, M20 coupling module, Screw terminal, AS-i interface to module upper part
AS-i flat cable connection, 4 inputs, Addressing socket, Three orientations of the flat cable are possible, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection, Sockets M12 x 1
AS-i flat cable connection, 2 safe inputs / 2 non-safe LED outputs, Safe AS-i input module 2SI - 2LO, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1
AS-i flat cable connection, 2x2 safe inputs / 2 non-safe LED outputs / 2 non-safe outputs, Safe AS-i input module 4SI / 2DO T / 2LO, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1
AS-i flat cable connection, 2 inputs / 2 outputs, Addressing socket, Three orientations of the flat cable are possible, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection, Digital inputs and outputs (2 A), Sockets M12 x 1
AS-i flat cable connection, 2 safe inputs / 2 non-safe LED outputs / 2 non-safe outputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1
AS-i flat cable connection, 4 outputs, Addressing socket, Three orientations of the flat cable are possible, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection, Sockets M12 x 1
AS-i flat cable connection, 2 safe inputs / 2 non-safe LED outputs / 2 non-safe outputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1
  • AS-i Safety at Work
  • Operating voltage DC 26.5...31.6 V
  • DC
  • M12 Connector
AS-i flat cable connection, 2 outputs / 2 inputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection, Sockets M12 x 1
AS-i flat cable connection, 4 inputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection, Sockets M12 x 1

ClassicLine splitter box module, AS-i flat cable connection, 4-way splitter box, Three orientations of the flat cable are possible, Sockets M12 x 1, AS-i and AUX splitter box for the connection of intelligent sensors/actuators

2 outputs / 2 inputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, Outputs supplied from AS-i, Sockets M12 x 1
AS-i flat cable connection, 3 outputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital outputs
AS-i flat cable connection, 4 inputs / 3 outputs, Addressing socket, Three orientations of the flat cable are possible, Version 2.11 and 3.0 with extended addressing mode, Sockets M12 x 1, Digital inputs and outputs
AS-i flat cable connection, 4 inputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital inputs
AS-i flat cable connection, 4 outputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital outputs
AS-i flat cable connection, 4 inputs / 4 outputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital inputs and outputs
AS-i flat cable connection, 8 digital inputs (2 slaves), Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital inputs
AS-i flat cable connection, 2 inputs / 2 outputs, Addressing socket, Three orientations of the flat cable are possible, Digital inputs and outputs (2 A), Sockets M12 x 1
AS-i flat cable connection, 4 inputs / 4 outputs, Addressing socket, Three orientations of the flat cable are possible, Digital inputs and outputs (2 A), Sockets M12 x 1
AS-i flat cable connection, 4 outputs, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital outputs 2 A
AS-i flat cable connection, 2 outputs / 2 inputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital outputs and inputs
2 analogue outputs 4...20 mA, Electrical isolation, Three orientations of the flat cable are possible, Sockets M12 x 1
AS-i flat cable connection, 2 inputs 4...20 mA, 2 analogue inputs, 4...20 mA, For the connection of 2-wire and 3-wire sensors, Addressing socket, Three orientations of the flat cable are possible
AS-i flat cable connection, 2 inputs 4...20 mA, 2 analogue inputs, 4...20 mA, For the connection of 2-wire and 4-wire sensors, Electrical isolation, Addressing socket, Three orientations of the flat cable are possible
2 outputs / 2 inputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, Outputs supplied from AS-i, Sockets M12 x 1, Digital outputs and inputs