IFM Pulse evaluation systems
- Speed monitor
- DC
- PNP/NPN
- M12 Connector
- simple evaluation of rotating and linear movement with regard to underspeed,blocking
Compact speed monitor M30, M30 x 1.5, DC PNP, ATEX approval, Group II, category 3D, Inductive sensor, Connector, Sensing range 10 mm [f] without impact protection housing [f], with impact protection housing [nf] 7 mm
MONITOR, Housing for DIN rail mounting, 2 analogue inputs 0/4...20 mA, 2 switching outputs (1 changeover contact and 1 x pnp each), 1 analogue output 0/4..20 mA, programmable, scaleable display, Comparator mode (In1-In2, In1+In2), Teach function, Key function, Signal and wire monitoring
- Threshold display
- Operating voltage DC 18...30 V
- DC
- M12 Connector
- decentralised display, preprocessing and conversion of analogue signals
- MONITOR
- Housing for DIN rail mounting
- 2 relay outputs
- 2 transistor outputs
- programmable
- Test function without external frequency
- Key function
- MONITOR
- Housing for DIN rail mounting
- 2 relay outputs
- 2 transistor outputs
- programmable
- Key function
- MONITOR
- Housing for DIN rail mounting
- 2 relay outputs
- 2 transistor outputs
- programmable
- Key function
MONITOR/FD-2N/230VAC
MONITOR/FD-2N/230VAC
- MONITOR
- Pulse difference monitor
- Housing for DIN rail mounting
- 2 relay outputs
- 2 transistor outputs
- programmable
- Adjustable reset time
- Key function
- MONITOR
- Pulse difference monitor
- Housing for DIN rail mounting
- 2 relay outputs
- 2 transistor outputs
- programmable
- Key function
- MONITOR
- Pulse difference monitor
- Housing for DIN rail mounting
- NAMUR inputs with wire monitoring
- 2 relay outputs
- 2 transistor outputs
- programmable
- Adjustable reset time
- Key function
MONITOR, Pulse difference monitor, Housing for DIN rail mounting, 2 relay outputs, 2 transistor outputs, programmable, Key function
- MONITOR
- Housing for DIN rail mounting
- programmable
- Analog output
- 0/4...20 mA; 0...10 V
- proportional / antiproportional
- averaging
- Teach function
- integrated pulse monitoring
- Key function
- 1 relay output
- 1 transistor output
- MONITOR
- Housing for DIN rail mounting
- programmable
- Analog output
- 0/4...20 mA; 0...10 V
- proportional / antiproportional
- averaging
- Teach function
- integrated pulse monitoring
- Key function
- 1 relay output
- 1 transistor output
MONITOR, Housing for DIN rail mounting, programmable, Analogue output, 0/4...20 mA, 0...10 V, proportional / antiproportional, averaging, Teach function, integrated pulse monitoring, Key function, 1 relay output, 1 transistor output
Digital display, Multi-functional display and evaluation system, Can be used for example as:, frequency meter/tachometer, processing time/baking time display, industrial timer, position and event counter, display of speed measured from elapsed time, 2 opto-coupler outputs
Digital display, Multifunction process display for analogue standard signals, 0/4...20 mA, 0...10 V, 2 independently scaleable inputs, scaleable display, Signal combination
- Digital display
- Operating voltage AC 115...230 V
- Operating voltage DC 18...30 V
- AC
- terminals
- universal evaluation and display for all physical units which can be derived from pulse sequences
- Digital display
- Operating voltage AC 115...230 V
- Operating voltage DC 18...30 V
- AC
- terminals
- universal evaluation and display for all physical units which can be derived from pulse sequences
- Digital display
- Operating voltage AC 115...230 V
- Operating voltage DC 18...30 V
- AC
- terminals
- universal evaluation and display for all physical units which can be derived from pulse sequences
- Digital display
- Operating voltage DC 18...30 V
- DC
- terminals
- universal evaluation and display for all physical units which can be derived from pulse sequences
- Digital display
- Operating voltage DC 18...30 V
- DC
- terminals
- universal evaluation and display for all physical units which can be derived from pulse sequences
- Digital display
- Operating voltage DC 18...30 V
- DC
- terminals
- universal evaluation and display for all physical units which can be derived from pulse sequences
- Digital display
- Operating voltage AC 115...230 V
- Operating voltage DC 18...30 V
- AC
- terminals
- displaying and monitoring analogue signals,e.g. pressure sensors, temperature sensors or flow sensors
- Digital display
- Operating voltage AC 115...230 V
- Operating voltage DC 18...30 V
- AC
- terminals
- displaying and monitoring analogue signals,e.g. pressure sensors, temperature sensors or flow sensors
- Digital display
- Operating voltage DC 18...30 V
- DC
- terminals
- displaying and monitoring analogue signals,e.g. pressure sensors, temperature sensors or flow sensors
- Digital display
- Operating voltage DC 18...30 V
- DC
- terminals
- displaying and monitoring analogue signals,e.g. pressure sensors, temperature sensors or flow sensors
- Digital display
- Operating voltage DC 18...30 V
- DC
- terminals
- displaying and monitoring analogue signals,e.g. pressure sensors, temperature sensors or flow sensors
- Electronic counter
- Housing for panel mounting
- programmable