  • 1-channel signal conditioner
  • 24 V DC supply
  • Input bipolar millivolt sources
  • Output bipolar current and voltage sources
  • Accuracy 0.1 %
  • Configurable via DIP switches and potentiometer
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input 2-wire transmitters
  • Dual output 0/4 mA ... 20 mA
  • Signal splitter (1 input and 2 outputs)
  • Accuracy 0.1 %
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input 2-wire transmitters
  • Input current and voltage sources
  • Dual output 0/4 mA ... 20 mA, 0/1 V ... 5 V or 0/2 V ... 10 V
  • Signal splitter (1 input and 2 outputs)
  • Accuracy 0.1 %
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input for 2- or 3-wire sensors or AC/DC voltage sources
  • Relay contact output
  • Timer function
  • Configurable by DIP switches
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input for 2- or 3-wire sensors
  • Input frequency 10 mHz ... 50 kHz
  • Relay contact output
  • Start-up override and restart inhibit
  • Configurable by DIP switches and software
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Thermocouple, RTD, potentiometer or mV input
  • Input for PTC thermistor
  • Current and voltage output
  • Line fault (LFD) and sensor burnout detection
  • Accuracy 0.1 %
  • Connection via screw terminals
  • 1-channel signal conditioner
  • Field side loop powered
  • Current input/output 0/4 mA ... 20 mA
  • Accuracy 0.1 %
  • Reverse polarity protection
  • Connection via screw terminals
  • 2-channel signal conditioner
  • Field side loop powered
  • Current input/output 0/4 mA ... 20 mA
  • Accuracy 0.1 %
  • Reverse polarity protection
  • Connection via screw terminals
  • Pluggable, mounts between device coupler and spur cable
  • Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose
  • Optional diagnostics for wear
  • Grounding of shield via gas-discharge tube
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Indication via LED and Advanced Diagnostics
  • Locate an operator workstation up to 120 m from server or pc
  • Operate keyboard, mouse, and monitor safely in a Div 2 hazardous area
  • Transparent operation between computer and monitor
  • Automatic skew compensation
  • Locate an operator workstation up to 400 m from server or pc
  • Operate keyboard, mouse, and monitor safely in a Div 2 hazardous area
  • Automatic skew compensation
  • Supports multimode fiber-optic cables
  • Locate an operator workstation up to 300 m from server or pc
  • Operate keyboard, mouse, and monitor safely in a Div 2 hazardous area
  • Easy installation and operation
  • Connection of TERMEX units as Siemens MPI Slave at the Siemens S7 MPI Bus
  • Conversion of the 3964/RK512 protocol in MPI and vice versa
  • No settings or configuration at the Siemens S7 necessary
  • Variable baud rate at the 3964R/RK512 end
  • 1- or 2-channel Division 2 non-incendive barrier
  • Div 2/Zone 2 mountable
  • USB or PS2 interface for Ex-rated keyboard or mouse
Fieldbus Barrier
Fieldbus Barrier