Pepperl+Fuchs Industrial Communication and Vision

  • Multiprotocol-compatible
  • M12 power connector
  • Sturdy metallic housing
  • Web-based configuration
  • Multiprotocol-compatible
  • M12 power connector
  • Sturdy metallic housing
  • Web-based configuration
  • 8 IO-Link ports Class A
  • Multiprotocol-compatible
  • M12 power connector, L-coded
  • Sturdy metallic housing
  • Web-based configuration
  • Extended temperature range
  • Web-based configuration of module and IO-Link devices
  • Integrated IODD storage for more than 100 IODDs
  • Downloadable module configuration
  • M12 L-coded power connector
  • EtherNet/IP, Modbus/TCP and OPC UA support
  • Web-based configuration of module and IO-Link devices
  • Integrated IODD storage for more than 100 IODDs
  • Downloadable module configuration
  • Screw terminal power connector
  • EtherNet/IP, Modbus/TCP and OPC UA support
  • Web-based configuration of module and IO-Link devices
  • Integrated IODD storage for more than 100 IODDs
  • Downloadable module configuration
  • M12 L-coded power connector
  • PROFINET IO, Modbus/TCP and OPC UA Support
  • Web-based configuration of module and IO-Link devices
  • Integrated IODD storage for more than 100 IODDs
  • Downloadable module configuration
  • PROFINET IO, Modbus/TCP and OPC UA Support
  • Pluggable push-in connectors
  • Web-based configuration of module and IO-Link devices
  • Integrated IODD storage for more than 100 IODDs
  • Downloadable module configuration
  • Screw terminal power connector
  • PROFINET IO, Modbus/TCP and OPC UA Support
  • Five - 10/100BASE-TX ports
  • Rugged housing for use in harsh environments
  • Alarm relay output for port event notifications
  • Redundant power input with wide input power range of 10 to 60VDC
  • Suitable for PROFINET IO and EtherNet/IP
  • C1D2 certification
  • Extended temperature range
  • Five - 10/100BASE-TX ports
  • Rugged housing for use in harsh environments
  • Alarm relay output for port event notifications
  • Redundant power input with wide input power range of 10 to 60VDC
  • Suitable for PROFINET IO and EtherNet/IP
  • Eight - 10/100BASE-TX ports
  • Rugged housing for use in harsh environments
  • Alarm relay output for port event notifications
  • Redundant power input with input power range of 18 to 32VDC
  • Suitable for PROFINET IO and EtherNet/IP
  • Extended temperature range
  • C1D2 certification
  • Eight - 10/100BASE-TX ports
  • Rugged housing for use in harsh environments
  • Alarm relay output for port event notifications
  • Redundant power input with input power range of 18 to 32VDC
  • Suitable for PROFINET IO and EtherNet/IP
  • Offline parameterization for all sensors with IO-Link interface
  • Automatic detection of the connected IO-Link USB Master and IO-Link sensor
  • Connection to the IO-Link sensor with just one click
  • Support of optional device DTMs
  • Rugged series in corrosion-resistant metal housing
  • Reliable recognition of reflective objects and clear glass
  • Two machines in one: clear object detection or reflection operating mode with long range
  • IO-link interface for service and process data
  • TEACH-IN switch for setting the contrast detection levels
  • Resistant against noise: reliable operation under all conditions
  • Miniature design with versatile mounting options
  • Best background suppressor in its class
  • Precision object detection, almost irrespective of the color
  • Extended temperature range
    -40?°C ... 60?°C
  • High degree of protection IP69K
  • IO-link interface for service and process data
  • Medium design with versatile mounting options
  • Best background suppressor in its class
  • Precision object detection, almost irrespective of the color
  • Extended temperature range
    -40?°C ... 60?°C
  • High degree of protection IP69K
  • IO-link interface for service and process data
  • Medium design with versatile mounting options
  • Space-saving distance sensors in small standardized design
  • Multi Pixel Technology (MPT) - exact and precise signal evaluation
  • IO-link interface for service and process data
  • Medium design with versatile mounting options
  • Space-saving distance sensors in small standardized design
  • Multi Pixel Technology (MPT) - exact and precise signal evaluation
  • IO-link interface for service and process data
  • Analog output 4 ... 20 mA
  • Medium design with versatile mounting options
  • Space-saving distance sensors in small standardized design
  • Multi Pixel Technology (MPT) - exact and precise signal evaluation
  • IO-link interface for service and process data
  • Analog output 0 ... 10 V DC
  • Medium design with versatile mounting options
  • Space-saving distance sensors in small standardized design
  • Multi Pixel Technology (MPT) - exact and precise signal evaluation
  • IO-link interface for service and process data
  • Analog output 0 ... 10 V DC
  • Medium design with versatile mounting options
  • Space-saving distance sensors in small standardized design
  • Multi Pixel Technology (MPT) - exact and precise signal evaluation
  • IO-link interface for service and process data
  • Medium design with versatile mounting options
  • Space-saving distance sensors in small standardized design
  • Multi Pixel Technology (MPT) - exact and precise signal evaluation
  • IO-link interface for service and process data
  • Analog output 4 ... 20 mA
  • High chemical resistance
  • Low weight
  • Self-adhesive mounting
  • High temperature resistance
  • High mechanical stability
  • Removable without residue
  • Easily interchangeable
  • EtherNet/IP
  • Non-contact positioning on Data Matrix code tape
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free
  • High resolution and precise positioning, especially for facilities with curves and switch points as well as inclines and declines.
  • Integrated switch
  • Travel ranges up to 10 km
  • No contact bounce
  • Precise sensing range thanks to RFID technology
  • Tamper-proof thanks to clear assignment of the active tag to the reader
  • Individual RFID coding that can be learned multiple times
  • Degree of protection IP65 / IP67
  • SIL3 / PLe
  • Connection of contact safety switches, e.g. EMERGENCY STOP button
  • Applications up to Cat. 4, PLe / SIL3
  • Modular safety solution
  • Ultra-compact enclosure
  • 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch
  • Housing with removable terminals
  • Communication monitoring
  • Power supply of outputs from the external auxiliary voltage
  • Power supply of inputs from the module
  • Function display for bus, ext. auxiliary voltage, inputs and outputs
  • Output overload monitoring
  • Switchable internal logic operation of the inputs and outputs via parameter bit
  • Addressing jack