Pepperl+Fuchs Products Other

  • 100 V AC to 240 V AC wide-range input
  • Output 24 V DC, 10 A, 240 W, 1-phase
  • Housing width 39 mm
  • Efficiency up to 95.2 %
  • Minimal inrush current surge
  • DC OK relay contact
  • Suitable for Zone 2/Div. 2 mounting
  • Enables easy, centralized management of a Remote Monitor via the VisuNet Control Center
  • Allows you to directly connect from a VisuNet Remote Monitor to a virtualized Emerson DeltaV system
  • Enables easy, centralized management of a Remote Monitor via the VisuNet Control Center
  • Diffuse mode sensor for recording any print mark
  • TEACH-IN, static and dynamic
  • 50 micro-s response time, suitable for extremely rapid scanning processes
  • 3 emitter colors: green, red and blue

EPV 2 SA 90

  • Sealing: EPDM, NBR
  • Maximum voltage: 250 V AC

EPV 3 SA 00

  • Maximum pressure: 0.3 bar (4.4 psi)
  • Vacuum: -0.08 bar (-1.2 psi)
  • Maximum Flow: 8 L/H (2.1 GPM)
  • Connections: G1/4, G3/8, NPT 1/8, M10 x 1
  • Sealing material: EPDM, FKM

EPV 3 SA 90

  • Diaphragm: Silicone rubber
  • Spring: Stainless steel
  • Maximum Voltage: 250V AC/DC
  • Maximum current: 10 A

EPV 6000 SS 01

  • Connection: G 1/4 A, internal thread
  • Fluid: Liquids and gases (compatible with 316L stainless steel)
  • Maximum flow rate: 30 l/min (7.925 gal/h)
  • Electrical signal: 4-20 mA
  • Supply voltage: 10...30 V DC
  • Current consumption: max. 20 mA
  • Response time: < 2 s

KFD2 CD2 EX2

  • Maximum current consumption: 100 mA
  • Response time: < 250 ms
  • Overcurrent protection: Yes
  • Short circuit protection: Yes

KFD2 GU 1

  • Resolution: 0.1°C or 0.1°F
  • Overload: 150% of the measurement range within 2 seconds
  • Short Circuit: The output is protected against short circuits to power and ground
  • Input resistance: RTD: ≤ 20 ohms
  • Thermocouple: ≤ 2 MΩ
  • Output resistance: ≤ 2 ohms

KFD2 STC4 2

  • Connection: Screw terminals
  • Mounting: On a 35 mm DIN rail according to EN 60715: 2001
  • EC type conformity certificate: BAS 99 ATEX 7025 X
  • Certificate: TÜV 99 ATEX 1499 X
  • IECEx certificate: IECEx BAS 04.0015X IECEx CML 15.0055X

KFD2 STV4 EX2 2

  • Input Impedance: Approx. 200 ohms
  • Maximum input voltage: 30 V
  • Reverse polarity protection: Built-in protection
  • Overcurrent protection: Built-in protection


LFL2 BK U PUR5

  • Rated voltage: 250 V AC / 150 V DC
  • Maximum current: 1 A DC / 3 A AC
  • Minimum switching current: 10 mA
  • Electrical strength: 2000 V AC
  • Degree of insulation resistance: > 100 MΩ
  • Voltage drop across contacts: < 1 V at nominal current
  • Switching time: < 10 ms

LFL2 CK U PUR3

  • Maximum switching power: 750 VA
  • Minimum switching current: 10 μA
  • Minimum switching power: 0.25 VA
  • Trigger time: < 10 ms
  • Trigger time: < 10 ms
  • Electrical strength: 2000 V AC
  • Insulation resistance: > 100 MΩ

LFL2 CK U PUR5

  • Process pressure (static pressure): ≤ 3 bar (43.5 psi) at 20°C (68°F)
  • Density: ≥ 0.8 g/cm³
  • Ambient temperature: 5 ... 70°C (41 ... 158°F)
  • Storage temperature: -25 ... 70°C (-13 ... 158°F)
  • Altitude: ≤ 2000 m above sea level
  • Degree of protection: IP68
  • Cable length: 5 m

LFL2 CK U PVC3

  • Maximum power: 25 VA
  • Minimum switching current: 10 mA
  • Minimum switching voltage: 1 V
  • Trigger time: ≤ 10 ms
  • Trigger time: ≤ 10 ms

LFL2 CK U PVC5

  • Degree of protection: IP65/IP67
  • Operating temperature range: From -20°C to +70°C
  • Installation: Vertical or horizontal

M LB 5000

  • Nominal current: Up to 2 A
  • Breakdown voltage: Up to 1 kV
  • Discharge energy: Up to 10 J
  • Input resistance: 10 ohms
  • Output resistance: 1 Ohm
  • Insulation resistance: > 10 GΩ

MB F95M Z1 V3

  • Trigger time: ≤ 2 ms
  • Trigger time: ≤ 5 ms
  • Reverse current: ≤ 1 mA
  • Breakdown voltage: ≥ 250 V DC. current
  • Electrical insulation resistance: ≥ 100 MΩ

MB80 12GM50 E0

  • Connection type: PUR cable, 2 m (black)
  • Core cross-section: 0.14 mm2
  • Body material: brass, nickel-plated
  • Sensitive surface: PBT
  • Degree of protection: IP67
  • Connections: BN, L+, L-, BK, BU

MB80 12GM50 E2

  • Power consumption: ≤ 1.5 W
  • Supply voltage: 10 ... 30 V DC
  • Nominal current: ≤ 100 mA
  • Maximum switching voltage: 250 V DC / 100 V AC
  • Maximum switching current: 2 A
  • Trigger time: ≤ 0.5 ms
  • Reset time: ≤ 0.5 ms

OJ 500 M1K E23

  • Body material: stainless steel
  • Degree of protection: IP67
  • Operating temperature: -25...70°C

PB D02 008 6

  • Button pressing force: 2.5 N
  • Button stroke: 4 mm
  • Button life: 1 million cycles
  • Installation: panel, on a DIN rail

PG11 CORD GRIP

  • Body: nickel-plated brass
  • Sealing: EPDM
  • Nut: nickel-plated brass

R2 SP IC4

  • Relative humidity: 0...95% (without condensation)
  • Body material: polycarbonate
  • Trigger voltage: 10.5 V DC

SJ5 K E2 Y33968

  • Current consumption: ≤ 10 mA
  • Residual current: ≤ 2 mA
  • Reverse polarity protection: Yes
  • Short circuit protection: Yes
  • Trigger time: ≤ 0.2 ms
  • Reset time: ≤ 0.1 ms
  • Hysteresis: ≤ 2%
  • Load capacity: 100 mA

TB RS DO16 AKB 204061

  • Output type: PNP
  • Maximum load voltage: 30 V
  • Minimum reset voltage: 0.8V
  • Output delay time: < 1ms
  • Output reset time: < 1ms

TC1200 1000

  • Degree of protection: IP64
  • Connection: Fixed cable with 9-pin Sub-D connector
  • Material: Body - ABS plastic

VAA 2E1A F85A S V1

  • Trigger force: max. 15 N
  • Trigger stroke: 5 mm
  • Reset force: max. 10 N
  • Reset stroke: 5 mm