Pepperl+Fuchs

Choose a subcategory:
Show all categories
  • Up to 5000 ppr
  • Industrial standard housing empty-58 mm
  • Servo or clamping flange
  • 10 V ... 30 V with RS 422 interface

Encoder Type: Incremental
Output signal: 10 ... 30 V DC, push-pull
Optical Resolution: 2500 cps

  • Industrial standard housing empty-58 mm
  • ATEX approval
  • Up to 5000 ppr
  • Servo or clamping flange
  • 5 V with RS-422 interface
  • Industrial standard housing empty-58 mm
  • ATEX approval
  • Up to 5000 ppr
  • Servo or clamping flange
  • 10 V ... 30 V with RS 422 interface
  • Up to 5000 ppr
  • Flameproof enclosure
  • Worldwide certification: ATEX, IECEx
  • EX-approval for mining
  • Degree of protection IP66 / IP67
  • High shaft load capacity
  • Temperature range -40 ... 158 В°F (-40В°C to 70В°C)
  • Up to 25 ppr
  • ATEX approval
  • Intrinsically safe
  • NAMUR interface in accordance with DIN EN 60947-5-6

The Product is out of Production!

20 ppr, 3000 rpm, 8 V, solid shaft: 10 mm, housing diameter: 84 mm, output: namur

  • Safe rotary encoder, thanks to integrated functional safety
  • Usable up to SIL 3 acc. to IEC 61508
  • TГњV certified
  • Suitable as motor feedback system for safe drives in accordance with IEC 61800-5-2
  • Incremental encoder with sin/cos interface
  • 1024 or 2048 signal periods
  • Thermally stabilized with the highest precision for high resolution interpolation
  • Isolated USB interface cable
  • Used with SC-System devices
  • Configurable via PC
  • Adapter for mounting a K-device to S1000 termination board
  • Snap-on
  • Additional cable sets depending on K-device
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input 2-wire and 3-wire SMART transmitters and current sources
  • Output 0/4 mA ... 20 mA
  • Accuracy 0.1 %
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input 2-wire and 3-wire transmitters and 2-wire current sources
  • Current and voltage output
  • Accuracy 0.1 %
  • Configurable by DIP switches
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input current and voltage sources
  • Current and voltage output
  • Accuracy 0.1 %
  • Configurable by DIP switches
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input bipolar current and voltage sources
  • Output bipolar current and voltage sources
  • Accuracy 0.1 %
  • Configurable via DIP switches and potentiometer
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input bipolar millivolt sources
  • Output bipolar current and voltage sources
  • Accuracy 0.1 %
  • Configurable via DIP switches and potentiometer
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input 2-wire transmitters
  • Dual output 0/4 mA ... 20 mA
  • Signal splitter (1 input and 2 outputs)
  • Accuracy 0.1 %
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input 2-wire transmitters
  • Input current and voltage sources
  • Dual output 0/4 mA ... 20 mA, 0/1 V ... 5 V or 0/2 V ... 10 V
  • Signal splitter (1 input and 2 outputs)
  • Accuracy 0.1 %
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input for 2- or 3-wire sensors or AC/DC voltage sources
  • Relay contact output
  • Timer function
  • Configurable by DIP switches
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input for 2- or 3-wire sensors
  • Input frequency 10 mHz ... 50 kHz
  • Relay contact output
  • Start-up override and restart inhibit
  • Configurable by DIP switches and software
  • Connection via screw terminals
  • 1-channel signal conditioner
  • 24 V DC supply
  • Thermocouple, RTD, potentiometer or mV input
  • Input for PTC thermistor
  • Current and voltage output
  • Line fault (LFD) and sensor burnout detection
  • Accuracy 0.1 %
  • Connection via screw terminals
  • 1-channel signal conditioner
  • Field side loop powered
  • Current input/output 0/4 mA ... 20 mA
  • Accuracy 0.1 %
  • Reverse polarity protection
  • Connection via screw terminals
  • 2-channel signal conditioner
  • Field side loop powered
  • Current input/output 0/4 mA ... 20 mA
  • Accuracy 0.1 %
  • Reverse polarity protection
  • Connection via screw terminals
  • Safety switch, 2 position with left OFF - 3x NO
  • Labeling '0 - I'
  • Auxiliary contacts - 1x NO
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Carbon loaded, antistatic glass fiber reinforced polyester
  • Bottom face cable glands polyamide, 2x M25 1x M20
  • Ex db eb and Ex tb certified
  • Padlockable switch
  • Degree of protection: IP 65