Pepperl+Fuchs

Choose a subcategory:
Show all categories
Series: Slot type, Housing material: PBT/PPS, Connection type: flexible leads LiY , 500 mm, Output type: 2-wire, Installation: , Type of voltage: DC
Series: Slot type, Housing material: PBT/PPS, Connection type: flexible leads LiY , 500 mm, Output type: 2-wire, Installation: , Type of voltage: DC
Series: Slot type, Housing material: PBT/PPS, Connection type: flexible leads LiY , 500 mm, Output type: 2-wire, Installation: , Type of voltage: DC
  • 3.5 mm slot width
  • Usable up to SIL 3 acc. to IEC 61508
  • Nonferrous targets
  • 3.5 mm slot width
  • Usable up to SIL 2 acc. to IEC 61508
  • Nonferrous targets
  • 3.5 mm slot width
  • Usable up to SIL 3 acc. to IEC 61508
  • Extended temperature range
  • 3.5 mm slot width
  • Usable up to SIL 3 acc. to IEC 61508
  • 30 mm slot width
  • 4-wire DC
Series: Slot type, Housing material: ABS, Connection type: cable PVC , 2 m, Output type: 2-wire, Installation: , Type of voltage: DC

Series: Slot type, Housing material: PBT, Connection type: flexible leads LiY , 500 mm, Output type: 2-wire, Installation: , Type of voltage: DC

Series: Slot type, Housing material: PBT, Connection type: cable PVC , 2 m, Output type: 2-wire, Installation: , Type of voltage: DC
  • Comfort series
Series: Slot type, Housing material: PBT, Connection type: flexible leads LiY , 500 mm, Output type: 2-wire, Installation: , Type of voltage: DC
  • Locate an operator workstation up to 120 m from server or pc
  • Operate keyboard, mouse, and monitor safely in a Div 2 hazardous area
  • Transparent operation between computer and monitor
  • Automatic skew compensation
  • Locate an operator workstation up to 400 m from server or pc
  • Operate keyboard, mouse, and monitor safely in a Div 2 hazardous area
  • Automatic skew compensation
  • Supports multimode fiber-optic cables
  • Locate an operator workstation up to 300 m from server or pc
  • Operate keyboard, mouse, and monitor safely in a Div 2 hazardous area
  • Easy installation and operation
  • Connection of TERMEX units as Siemens MPI Slave at the Siemens S7 MPI Bus
  • Conversion of the 3964/RK512 protocol in MPI and vice versa
  • No settings or configuration at the Siemens S7 necessary
  • Variable baud rate at the 3964R/RK512 end
  • 1- or 2-channel Division 2 non-incendive barrier
  • Div 2/Zone 2 mountable
  • USB or PS2 interface for Ex-rated keyboard or mouse
  • Sensing range 12 m
  • Visible red light, pulsed LASER light
  • Laser class 1, eyesafe
  • Performance Level PL e
  • Clearly visible LED functional display and pre-fault indicator on the receiver
  • Sturdy housing
  • Waterproof, degree of protection IP67
  • Operation on SB4-series control units (SafeBox)
  • Sensing range 30 m
  • Visible red light, pulsed LASER light
  • Laser class 1, eyesafe
  • Performance Level PL e
  • Clearly visible LED functional display and pre-fault indicator on the receiver
  • Sturdy housing
  • Waterproof, degree of protection IP67
  • Operation on control units of SB4 (SafeBox)
  • Sensing range up to 10 m
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Red transmission light
  • Integrated alignment aid
  • Clearly visible LED functional display and pre-fault indicator on the receiver
  • Sturdy housing
  • Waterproof, degree of protection IP67
  • Operation on control units of SB4 (SafeBox)
  • Sensing range up to 10 m
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Red transmission light
  • Integrated alignment aid
  • Clearly visible LED functional display and pre-fault indicator on the receiver
  • Sturdy housing
  • Waterproof, degree of protection IP67
  • Operation on control units of SB4 (SafeBox)
  • Sensing range up to 30 m
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Extended temperature range up to -35 В°C with heated front panel
  • Red transmission light
  • Integrated alignment aid
  • Clearly visible LED functional display and pre-fault indicator on the receiver
  • Operation of control units of Series SB4
  • Sensing range up to 65 m
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Red transmission light
  • Integrated alignment aid
  • Clearly visible LED functional display and pre-fault indicator on the receiver
  • Sturdy housing
  • Waterproof, degree of protection IP67
  • Operation on control units of SB4 (SafeBox)
  • Sensing range up to 30 m
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Red transmission light
  • Integrated alignment aid
  • Clearly visible LED functional display and pre-fault indicator on the receiver
  • Sturdy housing
  • Waterproof, degree of protection IP67
  • Operation on SB4-series control units (SafeBox)
  • Sensing range up to 4 m
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Red transmission light
  • Clearly visible LED functional display and pre-fault indicator on the receiver
  • Metal housing
  • Connection via M12 connector or fixed cable
  • Operation on control units of SB4 (SafeBox)
  • Degree of protection IP67 optional