Pepperl+Fuchs
Choose a subcategory:
Show all categories
- 4-channel
- Inputs Ex ia, Outputs Ex ia
- Installation in suitable enclosures in Zone 1
- Module can be exchanged under voltage (hot swap)
- Analog input, digital input,
analog output, digital output - Supply circuit 21.5 V (4 mA)
- HART communication via field bus or service bus
- Simulation mode for service operations (forcing)
- Line fault detection (LFD): one LED per channel
- Permanently self-monitoring
- Interface between the I/O modules and the PCS/PLC
- Com unit for 80 analog or 184 digital channels
- Communication via PROFIBUS DP
- Installation in suitable enclosures in Zone 1
- Module can be exchanged under voltage (hot swap)
- HART communication via PROFIBUS DP V1 or service bus
- Configuration via GSD parameters from the control system
- Non-volatile memory for configuration and parameter settings
- Self configuration in redundant systems
- Permanently self-monitoring
- Outputs drive to safe state in case of failures
- Interface between the I/O modules and the PCS/PLC
- Com unit for 80 analog or 184 digital channels
- Communication via PROFIBUS DP
- Installation in suitable enclosures in Zone 1
- Module can be exchanged under voltage (hot swap)
- HART communication via PROFIBUS DP V1 or service bus
- Configuration via GSD parameters from the control system
- Non-volatile memory for configuration and parameter settings
- Self configuration in redundant systems
- Permanently self-monitoring
- Outputs drive to safe state in case of failures
- Interface between the I/O modules and the PCS/PLC
- Com unit for 80 analog or 184 digital channels
- Communication via MODBUS RTU
- Installation in suitable enclosures in Zone 1
- Module can be exchanged under voltage (hot swap)
- HART communication via service bus
- Configuration via FDT 1.2 DTM
- Non-volatile memory for configuration and parameter settings
- Self configuration in redundant systems
- Permanently self-monitoring
- Outputs drive to safe state in case of failures
- Interface between the I/O modules and the PCS/PLC
- Com unit for 80 analog or 184 digital channels
- Communication via PROFIBUS DP
- Module can be exchanged under voltage (hot swap)
- HART communication via PROFIBUS DP V1 or service bus
- Installation in suitable enclosures in Zone 1
- Configuration via FDT 1.2 DTM
- Configuration in run (CiR) for any PCS
- Non-volatile memory for configuration and parameter settings
- Self configuration in redundant systems
- Permanently self-monitoring
- Outputs drive to safe state in case of failures
- Interface between the I/O modules and the PCS/PLC
- Com unit for 80 analog or 184 digital channels
- Communication via PROFIBUS DP
- Installation in suitable enclosures in Zone 1
- HART communication via PROFIBUS DP V1 or service bus
- Configuration via FDT 1.2 DTM
- Configuration in run (CiR) for any PCS
- Non-volatile memory for configuration and parameter settings
- Self configuration in redundant systems
- Permanently self-monitoring
- Outputs drive to safe state in case of failures
- Power supply for 95 - 230 V AC
- Suitable for the supply of FOL, field products (analyzers, level meters etc.)
- Installation in suitable enclosures in Zone 1
- Module can be exchanged under voltage (hot swap)
- Use two power supplies for redundancy
- Galvanic isolation to mains
- Power supply for 24 V DC
- Suitable for the supply of 24 I/O modules and 1 bus coupler
- Installation in suitable enclosures in Zone 1
- Module can be exchanged under voltage (hot swap)
- Power supply for 24 V DC
- Installation in suitable enclosures in Zone 1
- Module can be exchanged under voltage (hot swap)
- Multi range power supply 90 ... 253 V AC
- Suitable for the supply of 24 I/O modules and 1 bus coupler
- Use two power supplies for redundancy
- Installation in suitable enclosures in Zone 1
- Module can be exchanged under voltage (hot swap)
Remote I/O Unit
Remote I/O Unit
Remote I/O Unit
Remote I/O Unit
Remote I/O Unit
Remote I/O Unit
Remote I/O Unit
Remote I/O Unit
- Ex d and Ex tD certified
- Installation in Zone 1, Zone 2, Zone 21 and Zone 22
- Gas group IIC
- Aluminum enclosure
- Customizable configuration of operators, cable entry quantities and cable gland types as per specification
- Degree of protection IP66
- System board for Honeywell Universal Safety IO
- System board for Honeywell Universal Process IO
- For 16-channel cards USIO and UPIO
- For 16 modules
- Recommended modules: HiC2831R2 (DI), HiC2853R2 (DI), HiC2871 (DO), HiC2025 (AI), HiC2031 (AO)
- Recommended system cable: CAB-HON-**-S37C32-MX-01000
- 24 V DC supply
- Hazardous area: pluggable screw terminals, blue
- Non-hazardous area: Sub-D connector (male), 37-pin
- Mounting holes for simple installation
- Round, corner-cube reflector
- Rectangular, corner-cube reflector
- Temperature range: -4 В°F to +140 В°F
- Mounting holes for simple installation
- Reflective foil, square
- Foil cannot be cut
- Microstructure, rectangular, corner-cube
- For 20 analog or 40 digital channels
- Sensors in Zone 0/Div. 1 (depending on module assembly)
- Installation in Zone 2, Div. 2 or safe area
- HART communication via service bus
- For FOUNDATION Fieldbus H1
- Configured via the process control system
- Non-volatile memory for configuration and parameter settings
- Quick communication set-up
- Permanently self-monitoring
- Outputs drive to safe state in case of failures
- Module can be exchanged under voltage
- 16-channel
- Connection board for K-System HART Multiplexer
- Interface for parallel connections
- Connection via spring terminals
- System board for Triconex
- HART Termination Board (ETP) for Tricon v10 AI module
- For 16-channel AI cards 3700, 3700A, 3703E and 3721
- 16-channel
- Field side: screw terminals, green
- Control side: ELCO socket, 56-pin