Pepperl+Fuchs

Choose a subcategory:
Show all categories
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Current output up to 625 Omega- load
  • HART I/P and valve positioner
  • Low power dissipation
  • Suitable for long field cables (> 1000 m)
  • Up to SIL 2 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply
  • Resistance and RTD input (Pt100, Pt500, Pt1000)
  • Resistance output
  • Accuracy 0.1 %
  • Line fault detection (LFD) for Pt100
  • Up to SIL 2 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Thermocouple, RTD, potentiometer or voltage input
  • Linearized output 4 mA ... 20 mA, sink/source
  • Sensor breakage detection
  • Configurable by PACTware
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Analog input, digital input,
    analog output, digital output
  • No configuration required, device is self-adapting
  • HART transparency
  • Low power dissipation
  • 3-way isolation
  • Up to SIL 2 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Dry contact or NAMUR inputs
  • Usable as signal splitter (1 input and 2 outputs)
  • Relay contact output
  • Fault relay contact output
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508
  • 2-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Dry contact or NAMUR inputs
  • 2 relay contact outputs
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Dry contact or NAMUR input
  • Usable as signal splitter (1 input and 2 outputs)
  • 2 passive transistor outputs (resistive acc. to EN 60947-5-6)
  • Line fault transparency (LFT)
  • Up to SIL 2 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Dry contact or NAMUR inputs
  • Application-specific outputs
  • Usable as signal splitter (1 input and 2 outputs)
  • 2 passive transistor outputs (resistive)
  • Line fault transparency (LFT)
  • Up to SIL 2 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Dry contact or NAMUR inputs
  • Application-specific outputs
  • Usable as signal splitter (1 input and 2 outputs)
  • 2 passive transistor outputs (resistive)
  • Line fault transparency (LFT)
  • Up to SIL 2 acc. to IEC 61508
  • 2-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Dry contact or NAMUR inputs
  • Application-specific outputs
  • 2 passive transistor outputs (resistive)
  • Line fault transparency (LFT)
  • Up to SIL 2 acc. to IEC 61508
  • 2-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Dry contact or NAMUR inputs
  • 2 passive transistor outputs
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Input for approved dry contacts or SN/S1N sensors
  • Active voltage output
  • Passive transistor output (resistive acc. to EN 60947-5-6)
  • Line fault transparency (LFT)
  • Up to SIL 3 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Input for approved dry contacts or SN/S1N sensors
  • Active voltage output
  • Passive transistor output (resistive)
  • Line fault transparency (LFT)
  • Up to SIL 3 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (loop powered)
  • Output 45 mA at 12 V DC
  • Up to SIL 3 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (bus or loop powered)
  • Output 40 mA at 12 V DC, 55 mA current limit
  • Contact or logic control input
  • Entity parameter Io/Isc = 110 mA
  • Line fault detection (LFD)
  • Test pulse immunity
  • Up to SIL 2 acc. to IEC 61508 (bus powered)
  • Up to SIL 3 acc. to IEC 61508 (loop powered)
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Output 40 mA at 12 V DC, 55 mA current limit
  • Contact or logic control input
  • Entity parameter Io/Isc = 110 mA
  • Line fault detection (LFD)
  • Test pulse immunity
  • Up to SIL 2 acc. to IEC 61508 (bus powered)
  • System board for Schneider, Foxboro FBM series
  • For 8 modules
  • For 8-channel cards FBM201/214(b)/216(b) (AI), FBM215/218/237 (AO), FBM204/205 (AO/AI), FBM244 (AI/AO), FBM247/248 (UIO)
  • 24 V DC supply
  • Recommended modules: HiC2025 (AI), HiC2031 (AO), HiC2081 (TI), HiC2883 (DO), HiC2441 (UIO)
  • Hazardous area: screw terminals, blue
  • Non-hazardous area: Sub-D connector (male), 25-pin
  • For 8 modules
  • 24 V DC supply
  • Supported signal types: DI/DO/AI/TI/AO
  • Hazardous area: screw terminals, blue
  • Non-hazardous area: screw terminals, black
  • For 8 modules
  • 24 V DC supply
  • Supported signal types: DI/DO/AI/TI/AO
  • Hazardous area: screw terminals, blue
  • Safe area: Sub-D connector (male), 37-pin
  • System board for Schneider, Foxboro FBM series
  • For 16 modules
  • For 32-channel DI card FBM217
  • 24 V DC supply
  • Recommended module: HiC2842 (DI)
  • Hazardous area: screw terminals, blue
  • Non-hazardous area: Sub-D connector (male), 37-pin
Termination Board
Termination Board
  • For 16 modules
  • 24 V DC supply
  • Supported signal types: DI/DO/AI/TI/AO
  • Hazardous area: screw terminals, blue
  • Non-hazardous area: screw terminals, black
  • System board for Yokogawa CENTUM VP
  • For 32-channel DI card ADV151
  • For 16 modules
  • Recommended modules: HiC2822 (DI), HiC2842 (DI)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: Yokogawa system connector, 50-pin