Schneider Electric Soft Starter Altistrart
Choose a subcategory:
Show all categories
Product destination | Asynchronous motors |
Product specific application | Severe and standard applications |
Component name | ATS22 |
Network number of phases | 3 phases |
Power supply voltage | 230...600 V (- 15...10 %) |
Product destination | Asynchronous motors |
Product specific application | Severe and standard applications |
Component name | ATS22 |
Network number of phases | 3 phases |
Power supply voltage | 208...600 V (- 15...10 %) |
Product destination | Asynchronous motors |
Product specific application | Severe and standard applications |
Component name | ATS22 |
Network number of phases | 3 phases |
Power supply voltage | 230...440 V (- 15...10 %) |
Product destination | Asynchronous motors |
Product specific application | Severe and standard applications |
Component name | ATS22 |
Network number of phases | 3 phases |
Power supply voltage | 230...600 V (- 15...10 %) |
Product destination | Asynchronous motors |
Product specific application | Severe and standard applications |
Component name | ATS22 |
Network number of phases | 3 phases |
Power supply voltage | 208...600 V (- 15...10 %) |
ats22d
- Rated operating frequency: 50/60 Hz
- Maximum switching capacity: 6 kA
ats48c
- Operating temperature range: -10°C to +50°C
- Degree of protection: IP20
- Mounting: on DIN panel
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 208...690 V (- 15...10 %) |
Motor power kW | 90 kW at 440 V for severe applications 90 kW at 400 V for severe applications 55 kW at 230 V for standard applications 45 kW at 230 V for severe applications 200 kW at 690 V for standard applications 160 kW at 690 V for severe applications 160 kW at 660 V for standard applications 132 kW at 660 V for severe applications 132 kW at 525 V for standard applications 132 kW at 500 V for standard applications 110 kW at 525 V for severe applications 110 kW at 500 V for severe applications 110 kW at 440 V for standard applications 110 kW at 400 V for standard applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 208...690 V (- 15...10 %) |
Motor power kW | 75 kW at 230 V for standard applications 55 kW at 230 V for severe applications 250 kW at 690 V for standard applications 220 kW at 660 V for standard applications 200 kW at 690 V for severe applications 160 kW at 660 V for severe applications 160 kW at 525 V for standard applications 160 kW at 500 V for standard applications 132 kW at 525 V for severe applications 132 kW at 500 V for severe applications 132 kW at 440 V for standard applications 132 kW at 400 V for standard applications 110 kW at 440 V for severe applications 110 kW at 400 V for severe applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 230...415 V (- 15...10 %) |
Motor power kW | 250 kW at 400 V (connection to the motor delta terminals) for standard applications 220 kW at 400 V (connection to the motor delta terminals) for severe applications 160 kW at 400 V (connection in the motor supply line) for standard applications 160 kW at 230 V (connection to the motor delta terminals) for standard applications 132 kW at 400 V (connection in the motor supply line) for severe applications 132 kW at 230 V (connection to the motor delta terminals) for severe applications 90 kW at 230 V (connection in the motor supply line) for standard applications 75 kW at 230 V (connection in the motor supply line) for severe applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 208...690 V (- 15...10 %) |
Motor power kW | 90 kW at 230 V for standard applications 75 kW at 230 V for severe applications 315 kW at 690 V for standard applications 250 kW at 690 V for severe applications 250 kW at 660 V for standard applications 220 kW at 660 V for severe applications 220 kW at 525 V for standard applications 220 kW at 500 V for standard applications 160 kW at 525 V for severe applications 160 kW at 500 V for severe applications 160 kW at 440 V for standard applications 160 kW at 400 V for standard applications 132 kW at 440 V for severe applications 132 kW at 400 V for severe applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 230...415 V (- 15...10 %) |
Motor power kW | 315 kW at 400 V (connection to the motor delta terminals) for standard applications 250 kW at 400 V (connection to the motor delta terminals) for severe applications 220 kW at 400 V (connection in the motor supply line) for standard applications 220 kW at 230 V (connection to the motor delta terminals) for standard applications 160 kW at 400 V (connection in the motor supply line) for severe applications 160 kW at 230 V (connection to the motor delta terminals) for severe applications 110 kW at 230 V (connection in the motor supply line) for standard applications 90 kW at 230 V (connection in the motor supply line) for severe applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 208...690 V (- 15...10 %) |
Motor power kW | 90 kW at 230 V for severe applications 400 kW at 690 V for standard applications 355 kW at 660 V for standard applications 315 kW at 690 V for severe applications 250 kW at 660 V for severe applications 250 kW at 525 V for standard applications 250 kW at 500 V for standard applications 220 kW at 525 V for severe applications 220 kW at 500 V for severe applications 220 kW at 440 V for standard applications 220 kW at 400 V for standard applications 160 kW at 440 V for severe applications 160 kW at 400 V for severe applications 110 kW at 230 V for standard applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 230...415 V (- 15...10 %) |
Motor power kW | 355 kW at 400 V (connection to the motor delta terminals) for standard applications 315 kW at 400 V (connection to the motor delta terminals) for severe applications 250 kW at 400 V (connection in the motor supply line) for standard applications 250 kW at 230 V (connection to the motor delta terminals) for standard applications 220 kW at 400 V (connection in the motor supply line) for severe applications 220 kW at 230 V (connection to the motor delta terminals) for severe applications 132 kW at 230 V (connection in the motor supply line) for standard applications 110 kW at 230 V (connection in the motor supply line) for severe applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 208...690 V (- 15...10 %) |
Motor power kW | 500 kW at 690 V for standard applications 400 kW at 690 V for severe applications 400 kW at 660 V for standard applications 355 kW at 660 V for severe applications 315 kW at 525 V for standard applications 315 kW at 500 V for standard applications 250 kW at 525 V for severe applications 250 kW at 500 V for severe applications 250 kW at 440 V for standard applications 250 kW at 400 V for standard applications 220 kW at 440 V for severe applications 220 kW at 400 V for severe applications 132 kW at 230 V for standard applications 110 kW at 230 V for severe applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 230...415 V (- 15...10 %) |
Motor power kW | 400 kW at 400 V (connection to the motor delta terminals) for standard applications 355 kW at 400 V (connection to the motor delta terminals) for severe applications 315 kW at 400 V (connection in the motor supply line) for standard applications 250 kW at 400 V (connection in the motor supply line) for severe applications 250 kW at 230 V (connection to the motor delta terminals) for severe applications 160 kW at 230 V (connection in the motor supply line) for standard applications 132 kW at 230 V (connection in the motor supply line) for severe applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 208...690 V (- 15...10 %) |
Motor power kW | 560 kW at 690 V for standard applications 560 kW at 660 V for standard applications 500 kW at 690 V for severe applications 400 kW at 660 V for severe applications 400 kW at 525 V for standard applications 400 kW at 500 V for standard applications 355 kW at 440 V for standard applications 315 kW at 525 V for severe applications 315 kW at 500 V for severe applications 315 kW at 400 V for standard applications 250 kW at 440 V for severe applications 250 kW at 400 V for severe applications 160 kW at 230 V for standard applications 132 kW at 230 V for severe applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 230...415 V (- 15...10 %) |
Motor power kW | 500 kW at 400 V (connection to the motor delta terminals) for standard applications 400 kW at 400 V (connection to the motor delta terminals) for severe applications 355 kW at 400 V (connection in the motor supply line) for standard applications 315 kW at 400 V (connection in the motor supply line) for severe applications 315 kW at 230 V (connection to the motor delta terminals) for standard applications 160 kW at 230 V (connection in the motor supply line) for severe applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 208...690 V (- 15...10 %) |
Motor power kW | 630 kW at 690 V for standard applications 630 kW at 660 V for standard applications 560 kW at 690 V for severe applications 560 kW at 660 V for severe applications 400 kW at 525 V for severe applications 400 kW at 500 V for severe applications 400 kW at 440 V for standard applications 355 kW at 440 V for severe applications 355 kW at 400 V for standard applications 315 kW at 400 V for severe applications 160 kW at 230 V for severe applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 230...415 V (- 15...10 %) |
Motor power kW | 500 kW at 400 V (connection to the motor delta terminals) for severe applications 400 kW at 400 V (connection in the motor supply line) for standard applications 355 kW at 400 V (connection in the motor supply line) for severe applications 355 kW at 230 V (connection to the motor delta terminals) for standard applications 315 kW at 230 V (connection to the motor delta terminals) for severe applications 220 kW at 230 V (connection in the motor supply line) for standard applications 630 kW at 400 V (connection to the motor delta terminals) for standard applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 208...690 V (- 15...10 %) |
Motor power kW | 710 kW at 690 V for standard applications 710 kW at 660 V for standard applications 630 kW at 690 V for severe applications 630 kW at 660 V for severe applications 500 kW at 525 V for standard applications 500 kW at 500 V for standard applications 500 kW at 440 V for standard applications 400 kW at 440 V for severe applications 400 kW at 400 V for standard applications 355 kW at 400 V for severe applications 220 kW at 230 V for standard applications |
ats48d
- Operating temperature range: -10°C to +50°C
- Vibration and shock resistance
- Protection class IP20
ats48m
- Efficiency: 95%
- Number of inputs/outputs: 2 analog inputs, 1 analog output, 1 relay input, 1 relay output
- Type of enclosure: IP20
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 230...415 V (- 15...10 %) |
Motor power kW | 500 kW at 400 V (connection in the motor supply line) for standard applications 400 kW at 400 V (connection in the motor supply line) for severe applications 355 kW at 230 V (connection to the motor delta terminals) for severe applications 250 kW at 230 V (connection in the motor supply line) for standard applications 220 kW at 230 V (connection in the motor supply line) for severe applications 710 kW at 400 V (connection to the motor delta terminals) for standard applications 630 kW at 400 V (connection to the motor delta terminals) for severe applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 208...690 V (- 15...10 %) |
Motor power kW | 900 kW at 690 V for standard applications 900 kW at 660 V for standard applications 710 kW at 690 V for severe applications 710 kW at 660 V for severe applications 630 kW at 525 V for standard applications 630 kW at 500 V for standard applications 630 kW at 440 V for standard applications 500 kW at 525 V for severe applications 500 kW at 500 V for severe applications 500 kW at 440 V for severe applications 500 kW at 400 V for standard applications 400 kW at 400 V for severe applications 250 kW at 230 V for standard applications 220 kW at 230 V for severe applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 230...415 V (- 15...10 %) |
Motor power kW | 500 kW at 400 V (connection in the motor supply line) for severe applications 500 kW at 230 V (connection to the motor delta terminals) for standard applications 355 kW at 230 V (connection in the motor supply line) for standard applications 250 kW at 230 V (connection in the motor supply line) for severe applications 710 kW at 400 V (connection to the motor delta terminals) for severe applications 630 kW at 400 V (connection in the motor supply line) for standard applications |
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 208...690 V (- 15...10 %) |
Motor power kW | 900 kW at 690 V for severe applications 900 kW at 660 V for severe applications 800 kW at 525 V for standard applications 800 kW at 500 V for standard applications 710 kW at 440 V for standard applications 630 kW at 525 V for severe applications 630 kW at 500 V for severe applications 630 kW at 440 V for severe applications 630 kW at 400 V for standard applications 500 kW at 400 V for severe applications 355 kW at 230 V for standard applications 250 kW at 230 V for severe applications |
liquid level control relay
24..240Vac/dc
square d soft start
- Temperature range: -20°C to +55°C
- Degree of protection: IP20
- Certificates: UL, CSA, CE, RoHS